HONEYWELL BW™ RIGRAT Transportable Multi-gas Area Monitor

FEATURES AND BENEFITS

WIRELESS SAFETY PERIMETER

Position several Honeywell BW™  RigRat monitors to form a wireless safety perimeter.

REMOTE MONITORING 

Use with Honeywell’s remote monitoring software to see gas readings, location and other data

from any device with an internet connection — for fast, informed decisions. 

Add an optional noise  sensor or meteorological sensor.

OTHER HONEYWELL BWTM RIGRAT FEATURES:

• Line power for extended runtime in the field

• I/O ports providing additional input capabilities and local executive activation. 

• Inert mode that prevents alarm in normal ambient air. 

• Large, easy-to-read display

• Rugged, weatherproof design, with optional protective cage

HONEYWELL TOUCHPOINT™ PLUS COMPATIBLE

Use with the Honeywell Touchpoint™ Plus controller for visibility on

Honeywell BW™ RigRat monitors and workers’ personal detectors.

HONEYWELL BW™ RIGRAT TECHNICAL SPECIFICATIONS

HONEYWELL BW™ SOLO FEATURES AND BENEFITS

FEATURES AND BENEFITS

For even more time-saving convenience

— plus remote visibility on alarms

— choose the wireless version.

And manage it from your smartphone.

Pair the wireless Honeywell BW™ Solo with our Safety Communicator mobile

 app and detector readings are sent instantly to Honeywell’s real-time monitoring software

– Honeywell Safety Suite Real Time

– which can be accessed from any device with an internet connection, and get remote visibility on worker

safety and location.

You can also use the wireless Honeywell BW™ Solo to share gas data with the desktop software — no

dock required.

Other Honeywell BW™ Solo features: 

• Option to activate IntelliFlash™ or non-compliance flash

• Ability to assign detectors to workers and locations

• Easy-to-read display for multiple languages

• Data logging with rolling 24-hour peak reading

Honeywell BWTM Solo Technical Specifications

Honeywell BW™ Solo Compatible with IntelliDoX

Honeywell BW™ Solo is:

 • The easiest single-gas detector to service, with no need to take it apart to replace sensors,

batteries and sensor filters. That means long life and low cost.

 • Complete with an extensive selection of sensor options. Count on comprehensive detection,

whether you’re monitoring for common or exotic hazards.

 • The first single-gas detector with the 1-Series sensor for CO, H2S, O2and CO2

 . That means high accuracy, lower costs and faster sensor response time for the gases you monitor most

often.

 • Compatible with IntelliDoX.

Save time and centralize data with automated bump testing, calibration and instrument management.

Use IntelliDoX docking stations with Honeywell SafetySuite Device Configurator software

to maintain and monitor your entire fleet from practically anywhere.

Honeywell Touchpoint Plus Providing Ease and Efficiency 

Providing Ease and Efficiency 

• Quick and easy installation, configuration, setup, and maintenance

 • Easy diagnostics, data, and reporting

 • Minimum training time

 • Large color touchscreen LCD

 • Multilingual functionality

 • Green-yellow-red status at a glance

The signature feature of the Touchpoint line is a user-friendly touchscreen interface,

which the Touchpoint Plus takes to a new level. With this unique interface,

it’s easier than ever to see the status of your system at a glance

– maximizing the time you have to make the right decisions.

The intuitive, multilingual interface simplifies operation and reduces training requirements.

The full-color stoplight-style status indication provides clarity from a distance too.

Touchpoint Plus features a comprehensive set of outputs as standard,

including common alarms and dedicated drives for remote audiovisual indicators.

Its modularity enables you to customize your system to meet your specific application requirements.

Selecting the right detector for use with your controller can deliver significant

savings in startup costs and ongoing operations. 

Honeywell Touchpoint Plus Flexible Capabilities

Flexible Capabilities

 • Compatible with the full range  of Honeywell gas detectors

 • Powered audiovisual alarms  simplify field installation

 • Configuration includes easy  grouping and voting alarm logic without specialist knowledge

 • Next-generation compatibility 

• Optional Modbus output for integration with a higher level system

The full-color stoplight-style status indication provides clarity from a distance too.

Touchpoint Plus features a comprehensive set of outputs as standard,

including common alarms and dedicated drives for remote audiovisual indicators.

Its modularity enables you to customize your system to meet your specific application requirements.

Selecting the right detector for use with your controller can deliver significant

savings in startup costs and ongoing operations. 

Our global partner network and dedicated application specialists are

able to help you make the right choices for your industry.

With everything at your fingertips, you can take ownership of your system

and operate it with confidence, helping to ensure the safety of your people and the productivity of your

site.

Honeywell Analytics’ one system solution

Unique User Experience

Taking the user experience to a whole new level

One System Solution

Honeywell Analytics’ one system solution to meet your safety requirements

Touchpoint  Plus provides a reliable safety solution for small-scale gas detection systems

across a wide range of applications and industries.

If you need to integrate your gas detection with a higher level management system,

the Modbus output option makes this straightforward.

As the heart of your gas detection system, Touchpoint Plus is designed to work with

Honeywell’s industry-leading gas detectors and drive actuators,

and audible and visual alarms to provide a complete end-to-end solution that you can configure as your

own.

Designed for Speed and Reliability

TouchpointTM Made of high-impact polymer plastic, Plus is versatile and durable.

It is dustproof and waterproof, and has been tested to withstand the toughest operating environments,

both indoors and out. So you can count on the Touchpoint Plus to stand up to

the challenges of industrial environments, from mechanical rooms to chemical plants.

Touchpoint Plus is supplied with pre-drilled and sealed cable entries and a unique tiered

internal arrangement providing ease of access to save installers time and money.

Honeywell Optional DIN rail mounted Remote Terminal Panels

Remote Terminal Panels

Optional DIN rail mounted Remote Terminal Panels (RTPs)

are available for use with pre-wired cables to reduce installation

time and labor expense. Four types of RTPs are available:

 analog inputs, relay outputs, redundant I/O and other I/O modules.

Three cable lengths are also available to match hardware to installation variations.

Analog inputs RTPs include transmitter

shunt resistors and transmitter power terminals with individual circuit fuses.

The Relay Output RTP includes a fuse and power disconnect switch for each output.

All the three types of RTP panels also switch power to allow module removal and

installation under controller power. See page 36.

Terminal Blocks

20-screw Barrier style and Euro style terminal blocks are available

for use with all ControlEdge HC900 I/O Modules.

Red terminal blocks are used for high voltage connections

for added safety while black terminal blocks are used for low voltage connections.

A 36-terminal Euro style block is available with the 16 AI, the 8 and 16 AO

as well as the 32 DC DI and 32 DC DO module types.

Honeywell HC900 IO Modules ​Failsafe

Failsafe

All ControlEdge 900 Platform I/O modules support a user

specified failsafe value (analog) or state (digital) that the

module outputs or inputs will assume if communication

between the controller and the module is interrupted. Output

modules are also disabled if the controller fails to start.

Module diagnostics are not initiated if the control strategy

does not call for the inputs or outputs on the modules to execute.

Failsafe is restricted to de-energize in safety applications.

20-screw Barrier style and Euro style terminal blocks are available

for use with all ControlEdge HC900 I/O Modules.

Red terminal blocks are used for high voltage connections

for added safety while black terminal blocks are used for low voltage connections.

A 36-terminal Euro style block is available with the 16 AI, the 8 and 16 AO

as well as the 32 DC DI and 32 DC DO module types.

Honeywell HC900 Insert and Removal of I/O under Power

Overview

The Honeywell ControlEdge HC900 Controller is an

advanced loop and logic controller offering a modular design

sized to satisfy the control and data acquisition needs of a

wide range of process equipment.

Insert and Removal of I/O under Power

For ease of maintenance, the ControlEdge HC900 controller

supports removing and inserting I/O modules from the

module rack without removing power from the controller.

Each module is sensed for validity by the controller

and auto-configured on insertion.

Other Modules

In addition to I/O, the following modules are available.

• Scanner 1 module, single port (p.33)

• Scanner 2 Module, dual port (p.34)

• Universal AC Power Supply, 60W (p.6)

• Power Supply 24VDC, 60W (p.6)

• Redundant Switch Module (p.35)

• Power Status Module (p.35)

Honeywell ControlEdge HC900 IO Modules

I/O Modules

The following I/O modules are available to create a custom 

control solution.

• 16 Channel Universal IO Module Galavanically isolated

Input/Output to chassis (p.29)

• 8-point universal analog input modules: Galvanic

isolation point to chassis inputs may be mixed on a

module and may include multiple thermocouple types,

RTDs, ohms, voltage or mill voltage types – all easily

assigned using the Process Control Designer

configuration tool. High point-to-point galvanic isolation

simplifies installation and saves the expense of external

isolation hardware (p.8).

• 16-point high level analog input module: each point is

configurable for V or mA. Galvanically isolated point to

chassis. Galvanically isolated point to point (p.12). 250

ohm shunt resistors can be added per channel.

• 4-point galvanically isolated analog output module.

Galvanically isolated point to chassis supports from 0 to

20mA each (p.14).

• 8-point analog output, galvanically isolated in 2 groups

of 4 points. Galvanically isolated point to chassis.

Supports from 0 to 20mA each (p.15).

• 16-point analog output, galvanically isolated in 4 groups

of 4 points. Galvanically isolated point to chassis.

Supports from 0 to 20mA each (p.16).

• 16-point digital input modules: Contact closure type, DC

Voltage, AC Voltage and AC/DC voltage types (p.17).

Galvanically isolated in groups of 8 channel to chassis

• 32-point digital input module: DC voltage. Galvanically

isolated point to chassis. Galvanically isolated in 2

groups of 16 points (p.2117).

• 8-point AC or 16-point DC digital output modules

(sinking type). Galvanically isolated point to chassis.

Galvanically isolated in 2 groups of 8 points (p.20).

• 32-point digital output: DC voltage (sourcing type).

Galvanically isolated point to chassis. Galvanically

isolated in 2 groups of 16 points (p.25).

• 8-point relay output module: four form C type and four

form A type relays. Galvanically isolated point to

chassis. Galvanically isolated relay to relay (p.22).

• 4 channel Pulse/Frequency/Quadrature I/O module.

Galvanically isolated point to chassis (p.26).

Search for products