Johnson Controls DIS1710 Local Controller Display Installation Instructions

North American emissions compliance

United States

This equipment has been tested and found to comply with the limits for a Class A

digital device pursuant to Part 15 of the FCC Rules. These limits are designed to

provide reasonable protection against harmful interference when this equipment

is operated in a commercial environment. This equipment generates, uses, and

can radiate radio frequency energy and, if not installed and used in accordance

with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area may cause harmful interference,

in which case the users will be required to correct the interference at their own expense.

Canada

This Class (A) digital apparatus meets all the requirements of the Canadian

Interference-Causing Equipment Regulations.

Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement

sur le matériel brouilleur du Canada.

Installation

• Observe these guidelines when installing the DIS1710 display:

• Transport the display in the original container to minimize vibration and shock damage

to the unit.

• Verify that all parts were shipped with the display.

• Do not drop the display or subject it to physical shock.

Johnson Controls DIS1710 Local Controller Display is a stand-alone display module

Applications

The DIS1710 Local Controller Display is a stand-alone display module designed

for installation on the front panel of an enclosure. The DIS1710 display can

connect to the Network Control Engine (NCE), Field Equipment Controller (FEC),

or Advanced Application Field Equipment (FAC) models that do not have integral

displays. The display provides a local user interface for the application running in

the controller. Use the Controller Configuration Tool (CCT) tool to configure the display.

Installation

• Observe these guidelines when installing the DIS1710 display:

• Transport the display in the original container to minimize vibration and shock damage

to the unit.

• Verify that all parts were shipped with the display.

• Do not drop the display or subject it to physical shock.

Parts included

• One DIS1710 Local Controller Display

• One communication cable

• One O-ring

• One installation instructions sheet

Materials and special tools needed

• Power saw for cutting a hole into the panel to hold the display, if no hole is provided

• Small Phillips-head screwdriver

Johnson Controls WRZ Series Features


Models are available with or without an LCD.

Depending on the sensor model, the WRZSeries Sensor can transmit sensed temperature,

setpoint temperature, sensed humidity, occupancy status, and low battery conditions to

an associated router or receiver. The WRZ Series Sensors are designed for indoor, intra-building

applications only.

The WRZ Series Sensors use direct-sequence, spread-spectrum RF technology, and operate on

the 2.4 GHz Industrial, Scientific, and Medical (ISM) band.

The receiver meets the IEEE 802.15.4 standard for low-power, low-duty cycle RF transmitting

systems.

Refer to the WRZ Series Wireless Room Sensors Product Bulletin (LIT-12011653) for important

product application information.

Features

• Wireless RF Design

• Integral Wireless Signal Strength Testing Built into the Sensor

• Easy Installation and Relocation

• Easily Applicable Data Types

• Simple, Field-Adjustable DIP Switches

• Wireless Signal Strength and Low Battery Condition Mapping

• Optional, Battery-Powered WRZ-SST-120 Wireless System Survey Tool

• High Resistance to RF Interference from Other Radio Devices or RF Noise Sources

• Onboard PIR Occupancy Sensor Available on Some Models

• User-Selectable Default Display for Humidity Models

• Display Models

• Three Temperature Setpoint Range Options

• Blinking Red LED Light to Indicate Firmware Version

Johnson Controls Local Controller Display Operation Overview

Local Controller Display Operation Overview

The Local Controller Display uses a fixed set of display pages to organize the

objects and data defined in the controller. Use the keypad to log on to the device

and navigate between and within each page. See Local Controller Display Keypad

for navigation information. You cannot change the order of the pages, but you can

change the contents of the pages when you configure the display with CCT.

Description of Local Controller Display

The pages that you access from the display’s Main Menu share a common layout

and theme. For example, all pages have a page title and a scroll bar used to

navigate the page. In addition, all pages support four lines of text.

If a text field shown on the Local Controller Display exceeds 20 characters, the

text scrolls across the screen once and then remains left justified with trailing

ellipses to indicate the entire text is not showing. For example, Floor1 Zone

Temperature may be shortened as Floor1 Zone Temper…. Text characters not

supported by any available character are displayed as asterisks.

Text is also shortened if the data field for the object exceeds the total allocated

width. For example, if the value of an object is 12345.67. the displayed value may

be shortened to 12345 (depending on its initial length).

Johnson Controls FX-DIS Local Controller Display

Local Controller Display Configuration

FX-PC controllers with a local display, or controllers with the remote stand-alone

display, are configured with CCT. The CCT provides a Configure Display menu

option that allows you to:

• define which points appear on the display pages (Input/Output View,

Parameter/Setpoint View, and Idle View) and in which order

• define which points are read-only (cannot be commanded using the display)

• specify point names and descriptions

• set display attributes including contrast and backlight intensity

• select timeout settings

• select authorization, including password definition

These options are available in CCT through the Configure Display option found in

the Tools menu while in Configuration mode. 

Pages on the Local Controller Display:

• share a common method of row selection

• use a common method of entering data within an editable field

• show a scroll bar to indicate the scrolling feature is enabled

• support scrolling of rows and data that span multiple screens

• share a common method of wrapping row selection when the endpoints of the

rows in a list have been reached

• update their values every 5 seconds (Present Value and Reliability attributes) or

120 seconds (all other attributes)

Johnson Controls WRZ Series Wireless Room Sensors

Description

The WRZ Series Wireless Room Sensors are designed to sense room or zone temperature

and transmit wireless temperature control data. Some models also sense and transmit

relative humidity (RH).

Several models include an onboard passive infrared (PIR) occupancy sensor that detects

motion to determine if a space is occupied.

This feature maximizes up to 30% energy savings in high-energy usage environments

such as schools, dormitories, offices, and hospitals by adjusting the temperature of the

space based on the occupancy status. In addition, the PIR occupancy sensor facilitates

trending of floor space usage in these environments.

In a ZFR1800 Series Wireless Field Bus System application, the sensors communicate

with FAC26 Series, FEC16 Series, FEC26 Series, and VMA16 Series Controllers by

means of the ZFR18xx Series Router.

In wired field bus applications, the sensors communicate with a WRZ-7860 Wireless

Receiver. The WRZ-7860 Receiver transfers data to the controller by means of the Sensor

Actuator (SA) communication bus. In a typical application, one WRZ Series Sensor reports

to one WRZ-7860 Receiver, but up to five WRZSeries Sensors can be associated with a

single WRZ-7860 Receiver for multi-sensor averaging or high/low temperature selection.

The WRZ Series Wireless Room Sensors include models with either a temperature

setpoint dial or the setpoint adjustment pushbuttons and LCD that allows occupants

to view the zone temperature, Relative Humidity (RH), and view and adjust the zone

temperature setpoint. Some temperature and humidity models include a %RH pushbutton

to toggle between temperature and RH on the display. These models also have the capability

to set the desired default display to either temperature or RH. Some models also include

a °F/°C button, which provides a choice between degrees Fahrenheit (F) and degrees

Celsius (C).

Johnson Controls 4007ES Hybrid, Fire Detection and Control Unit

Mechanical description

• Locking door with polycarbonate window.

• Latching front panel assembly swings forward for convenient

internal access.

• Smooth box surfaces are provided for locally cutting conduit

entrance holes exactly where required.

• Modules are power-limited except as noted, such as relay

modules.

• The battery compartment at the bottom, has space for two

batteries, up to 18 Ah. You can mount batteries within the cabinet

without interfering with module space. Charger capacity is up to

33 Ah. For information about batteries greater than 18 Ah and

external battery cabinets, see Module and accessories selection

information.

• Cabinet assembly design has been seismic tested and is certified

to IBC and CBC standards also to ASCE 7 categories A through

F, requires battery brackets. For more information, refer to data

sheet S2081-0019.

• Seismically compliant under the State of California Statewide

Office of Housing and Development (OSHPD) Special Seismic

Certification (SSC) program guidelines. Refer to Simplex Seismic

Application Guide 579-1213 and Battery Brackets for Seismic Activity

Applications S2081-0019 for details.

Johnson Controls 4007ES Series Convenient status information

Operator interface

Convenient status information

If the locking door is closed, through the glass window, you can view

the display status of the LEDs. The user interface is a 4.3 in. (109

mm) diagonal color touchscreen LCD with separate status LEDs. See

Figure 2.

LED indicators describe the general category of activity displayed and

the LCD provides more detail. Authorized users can unlock the door

to gain access to the control functions and scroll through the display

for additional detail.

Operator interface and software features

• Convenient and detailed operator information is easily accessible

using a logical, menu-driven touchscreen display with password

access control

• Multiple automatic and manual diagnostics for maintenance

reduction

• Alarm and Trouble History Logs, up to 1000 entries for each, 2000

total events. You can view these events from the display or print

them out on connected printer, or download them to a service

computer.

• Module level ground fault searching assists installation and

service by locating and isolating modules with grounded wiring

• WALKTEST silent or audible system test performs an automatic

self-resetting test cycle and supports up to eight WALKTEST

groups

• Install Mode can group multiple troubles for uninstalled modules

and devices into a single trouble condition, typical with future

phased expansion. With future equipment and devices grouped

into a single trouble, operators can clearly identify events from

the commissioned and occupied areas.

Johnson Controls 4007ES Series Fire Detection and Control Units

Introduction

4007ES Series Fire Detection and Control Units provide extensive

installation, operator, and service features with point and module

capacities suitable for a wide range of system applications. You can

configure Panels for stand alone or networked fire control operation.

The convenient and intuitive color touchscreen provides easy access

for typical system response actions and for detailed system review or

configuration updates with password control to limit user access.

Standard conventional IDCs and addressable IDNet 2

communications provide flexibility for both new and retrofit systems.

For IDC and NAC, you can select EOL resistor values to match a wide

range of existing initiating device circuits and notification appliance

circuits.

ES panel compatibility with ES Net

Simplex ES Network (ES Net) is a next generation IP-based fire

network that uses industry standard network technology and

infrastructure, and facilitates simplified network upgrades, easy

terminal connectivity and IP file transfer between nodes, and

advanced network diagnostics.

You can upgrade ES fire alarm control units (FACUs) to operate on an

ES network by adding an ES Net NIC to the panel.

To upgrade an existing 4120 network to ES Net, you must replace all

of the 4120 NIC cards on the network loop with ES Net NICs.

Note: ES Net NICs and 4120 NICs cannot be mixed on the same

network loop.

For more detailed information about ES Net, refer to data sheet

S4100-0076. and talk to your local Simplex product supplier.

Johnson Controls 4007ES Optional modules and connections include

Software feature summary:

• Current and previous panel configuration is maintained in on

board memory

• An internal Ethernet service port is available for service computer

connections to perform configuration updates, downloads and

uploads, report downloads, and update system software

• You can use the internal USB interface with a memory stick to

store job revisions, update revised jobs and panel software, and

save detailed system reports from the panel.

Optional modules and connections include:

• Fire alarm network interface card (NIC) for ES Net or 4120 network

• Peer-to-peer network communications, supports either Class B or

Class X operation

• Point or Event DACT assembly for Connected Services Gateway

• Up to two additional IDNet 2 addressable device output loop

connections with short circuit fault protection and with 75

additional point capacity each.

• Front mounted 32 LED and 32 LED/switch annunciator with

custom label inserts. LEDs are programmable for up to 32

IDC zones of alarm and trouble annunciation or other custom

annunciation requirements.

• Remote LED annunciator support through remote user interface

(RUI) communications port for use with UTP wiring.

• Dual RS-232 ports for printer, PC annunciator, or third party interface.

• Alarm relays and auxiliary relays.

• City connections, with or without a disconnect switch.

• 4009 IDNet NAC Extenders to extend NAC capability for power and

distance

• Battery brackets for seismic area protection. 