Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Honeywell X-DCS2000/EN Broadcasting

Broadcasting

DCS supports a variable range of audio sources, such as audio fi les from external devices

(CD/DVD, cassette, FM tuner and etc.), remote paging announcement or broadcasting from

X NPMI, announcements from the PTT emergency microphone etc.

DCS can broadcast 4 audio message or internet audio simultaneously. Timer broadcast

setting can be confi gured via software to allow system to play specifi cprograms at a specific

time even when it is not supervised. With the software, user can also handle up to 255

priorities to meet complex public address requirements.

Zone Control

User can select audio sources and zones to broadcast by clicking directly on the control

buttons on the front panel.

DCS supports audio matrix, allowing any audio sources to be played in any zones.

Monitoring

DCS has a built-in loudspeaker and it can enable zone and audio source monitoring.

When the system has been extended via Ethernet, network remote supervision can be

performed.

Shortcut Control

A highlight of DCS is the one-click emergency mode switchover feature. A red emergency

mode button can be found on the front panel, which can activate the fi re alarm broadcast

mode in an emergency by a single click. In emergency mode, the recorded evacuation

announcement will be broadcasted and the zone alarm indicator lights will be turned on.

This function signifi cantly improves the evacuation effi ciency.

Users can preset the functions for the other buttons or their combo usage.The label

describing buttons’ functions can be replaced easily.

Honeywell X-DCS2000/EN Safety and Robustness

Safety and Robustness

DCS can detect errors on main power supply, backup power supply, amplifier circuit,

amplifier protection, software, communications, and loudspeaker line in runtime.

By locating the error’s occurrence, DCS provides valuable information for repairing

or replacing the malfunctioned devices.

DCS supports power supply and amplifier redundancy. Built-in fuse provides over-current

protection to the main power supply. When a shortcircuit error is detected in DCS, the

power supplied from main power will be cut off and switched to the backup one.

Same technology is also used in amplifier switchover. User can configure the amplifier

backup solution as 3 backup for 1 main, 2 backup for 1 main, 1 backup for 1 main or

2 backup for 2 main.

Audio Storage

DCS is built with a 1GB flash memory. Via X-618 Config software, users can upload audio

files for later playback or audio synthesis. Volume controllers can be connect- ed with

the DCS contact outputs to adjust the zones volume or force switching.

Honeywell X-DCS2000/EN FEATURES

FEATURES

Input/ OutputDCS has 8 dry-contact outputs that canbe used to activate external devices.

It has 8 pairs of loudspeaker line output where each one allows multiple 100V

loudspeakers to be connected in parallel. A record output port is dedicated for

external recording.

DCS also has 8 dry-contact inputs that can be linked with a fire alarm control

center which supports broadcasting alarm tones and evac- uation announcement

when fire happens. On the rear panel, there are 4 network audio input and 4

auxiliary inputs, which provide con- nections to external audio sources such as

CD/DVD, cassette, FM tun- er etc. In addition, there are 4 audio inputs that are

capable to adjust volume automatically according to ambient noise (when HN-D32N

Noise Detector is installed). Users can set the phantom power and input gain of

each volume control input on the rear panel.

Connections Expansion

DCS can connect with devices and the network to extend zone connections via

4 10M/100M adaptable Ethernet interfaces.

Honeywell X-DCS2000/EN DIGITAL INTEGRATED SYSTEM MANAGER

DESCRIPTION

X-DCS2000/EN Digital Integrated System Manager (abbr. DCS) is the basic unit

of X-618 Public Address and Voice Alarm System. DCS integrates plentiful

functions such as zone expansion, multiple audio sources support, audio file

storage, net audio, broadcasting, zone control, monitoring, fault diagnosis etc.

The supplied X-SMART management software allows users to easily and efficiently

manage and control the system.

Shortcut Control

A highlight of DCS is the one-click emergency mode switchover feature. A red emergency

mode button can be found on the front panel, which can activate the fi re alarm broadcast

mode in an emergency by a single click. In emergency mode, the recorded evacuation

announcement will be broadcasted and the zone alarm indicator lights will be turned on.

This function signifi cantly improves the evacuation effi ciency.

Users can preset the functions for the other buttons or their combo usage.The label

describing buttons’ functions can be replaced easily.

Honeywell MICRO SWITCH premium subminiature switches

DIFFERENTIATION

• Very wide temperature range allows for years of reliable

performance in the harshest of conditions

• MIL-PRF-8805 qualified listings

• Operating forces as low as 0.06 N [6 g] and differential travel

as low as 0.025 mm [0.001 in] delivers consistent, precise

switch characteristics

FEATURES

• Industry-leading mechanical life of up to 10.000.000 operations

• Selection of actuation, electrical termination, and operating

characteristics along with high-temperature construction options

• Wide temperature range of -54°C to 204°C [-65°F to 400°F]

• MIL-PRF-8805 qualified listings in a lightweight, small package

• FAA-PMA approvals for commercial aircraft

• Choice of silver or gold-plated, or gold bifurcated contacts to

handle a variety of electrical load requirements

• UL/CSA, cUL, ENEC, and CE approvals

VALUE TO CUSTOMERS

• Industry-leading life cycle rating reduces the need to

replace switches over life in an OEM platform – reducing

total system cost

• Low operating forces

• Mil-qualified listings

• Life of up to 10.000.000 cycles

Honeywell MICRO SWITCH Premium Subminiature Basic Switches

DESCRIPTION

The industry-defining name in snap-action switches,

Honeywell MICRO SWITCH premium subminiature switches

are designed for repeatability and enhanced product life. The

MICRO SWITCH SM Series delivers consistent performance

within a range of conditions.

The MICRO SWITCH SM Series’ small size and light weight are

combined with ample electrical capacity, precision operation,

and extended life. Featuring high precision and repeatability,

the SM Series offers gold contacts for low-energy switching

and gold bifurcated contacts for maximum reliability.

Bifurcated contacts provide parallel redundancy within the SM

switch.

The SM switch is available for power-duty switching up to 11 A

(Vac) or 1/4 HP (Vac).

POTENTIAL APPLICATIONS

• Precision switch assemblies for commercial aircraft to

monitor doors for “closed” and “locked” position

•  Landing gear monitor

•  Precision switch assemblies for commercial cockpit

applications for pushbuttons, toggle, or joystick assemblies

•  Precision switch assemblies in military applications

• Assemblies for industrial pressure switches and temperature

switches

• Power generation fuel level (gas and oil)

PORTFOLIO

The SM Series of premium subminiature basic switches are

a part of a strong offering of submins including SX Series

(premium) and ZM, ZM1. ZD, ZX, and ZW Series (standard) switches.

Honeywell 91MCE Series MICRO SWITCH Miniature Compact Limit Switches Features

Warranty/Remedy

Honeywell warrants products manufactured by it to be free from defects

in material and workmanship for the applicable warranty period.

Honeywell’s standard product warranty applies unless otherwise agreed to in writing by Honeywell;

For specific warranty details, refer to your order confirmation or consult your local sales office.

If the warranted product is returned to Honeywell during the warranty period,

Honeywell will, at its sole discretion, repair or replace, free of charge, the product that Honeywell deems

to be defective.

The foregoing is Buyer’s exclusive remedy and is in lieu of all other warranties, express or implied,

including the following warranties

merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for

consequential, special or indirect damages.

Honeywell may provide application assistance in person, through our materials and through Honeywell

websites.

and Honeywell websites for application assistance, but it is the sole responsibility

of the buyer to determine the suitability of the product for the application.

Specifications are subject to change without notice.

As of this writing, the information we have provided is believed to be accurate and reliable.

However, Honeywell assumes no responsibility for its use.

Honeywell 91MCE Series MICRO SWITCH

ORTFOLIO

The 91MCE series is part of the 14CE, 914CE, NGC, SZLVL-S, SSCE and SL1 series of miniature limit

switches.

Honeywell also offers a range of MICRO SWITCH heavy duty limit switches and general purpose limit

switches.

Features

– Direct-acting contacts designed to open NC contacts when touched

– Sealing class IP67; NEMA 1. 4. 12. 13 for outdoor applications

– CE, UKCA, cULus, CCC approvals meet most global certification requirements

– Nine actuator styles provide design flexibility

– Slow-action and fast-action circuit options

– Reserved cable and M12 connector options

– Mechanical life expectancy: 5 million operations

– Side exit (standard) and bottom exit connection options

Side outlet (standard) and bottom outlet connection options

– Mechanical equipment

– Material handling

– Aerial lift trucks

– Forklift trucks

– Off-road and outdoor equipment

Honeywell Touchpoint Plus Flexible Capabilities

Flexible Capabilities

 • Compatible with the full range  of Honeywell gas detectors

 • Powered audiovisual alarms  simplify field installation

 • Configuration includes easy  grouping and voting alarm logic without specialist knowledge

 • Next-generation compatibility 

• Optional Modbus output for integration with a higher level system

The full-color stoplight-style status indication provides clarity from a distance too.

Touchpoint Plus features a comprehensive set of outputs as standard,

including common alarms and dedicated drives for remote audiovisual indicators.

Its modularity enables you to customize your system to meet your specific application requirements.

Selecting the right detector for use with your controller can deliver significant

savings in startup costs and ongoing operations. 

Our global partner network and dedicated application specialists are

able to help you make the right choices for your industry.

With everything at your fingertips, you can take ownership of your system

and operate it with confidence, helping to ensure the safety of your people and the productivity of your

site.

Honeywell BW™ ICON Multi-Gas Detector

FEATURES AND BENEFITS

RELIABLE

Two months of battery runtime on a 4.5-hour charge

— and up to four months if you turn off the detector at the end of each shift.

No daily charging, no unexpected downtime.

EASY TO MANAGE

The IntelliFlash™ green light indicates when the detector is in compliance

and the amber light indicates the need for maintenance.

COMPATIBLE

The Honeywell BW™ Icon is compatible with the IntelliDoX instrument management

system and Honeywell Safety Suite and also with TouchConnect™ using Bluetooth® for 

wireless configuration.

RESPONSIVE

1series sensors respond to dangerous gas levels in seconds, even in harsh temperatures.

ACCURATE

Low-power infrared LEL sensor is immune to silicone poisoning,

which means accurate monitoring of combustibles.

EASY TO USE

Small, lightweight and wearable.  One-button operation.

Honeywell BW™ Icon Technical Specifications

Search for products

Back to Top
Product has been added to your cart