A-B 1336E-B075-AE-EN-HA2-L6 Adjustable Frequency Drive

It is rated at 380 to 480 volts AC, 56 kilowatts and 75 horsepower.

It is equipped with a programmer/controller with digital potentiometer HMI to simplify drive control and programming.

Up to 16 programmable speed command transitions are available on the drive, which supports SCANport communications and English as the programming language.

The 1336E-B075-AE-EN-HA2-L6 IMPACT drive is designed to provide unrivaled speed control.

The diagnostic features on this drive allow real-time monitoring of its logic board and power structure.

It has 32 entry fault queues and 32 entry warning queues with markers for clearing faults and timestamping power-ups.

Flying start mode on this drive applies to motors that are already spinning loads.

As with all B-frame 1336 IMPACT drives, the 1336E-B075-AE-EN-HA2-L6 drive does not support network connectivity through an isolated gateway.

Its memory storage is non-volatile, and it has a NEMA 1 (IP20)/EMC enclosure and a 115-volt AC control interface.

The function blocks on this drive provide greater flexibility than other drives.

Connecting the 1336E-B075-AE-EN-HA2-L6 IMPACT Drive to a Motor Using a Long Cable

Cable terminators or output chokes may be required to minimize voltage reflections at the motor terminals.

It can be fitted with different types of cables including shielded, unshielded and armored cables.

The drive is designed to use a three-phase power supply that is symmetrical to ground and supports the use of a line reactor or isolation transformer if the power supply encounters power line conditions that could cause a fault.

This 1336 PLUS II adjustable frequency AC drive is a 380-480VAC unit with 56 (75) kilowatts (kW) of power (horsepower) and has an (n) NEMA 1 (IP20)/EMC enclosure.

A-B 140G-G2C3-C15 Molded Case Circuit Breaker

About Allen-Bradley The 140G-G2C3-C15 Molded Case Circuit Breaker is a thermal magnetic circuit breaker in the 140G circuit breaker series designed to provide short circuit protection for a variety of control panel applications.

As with all 140G circuit breakers, the 140G-G2C3-C15 circuit breaker is sized in accordance with Table 430-152 of the NEC (National Electrical Code).

The 140G-G2C3-C15 circuit breaker is suitable for branch or main circuits operating at 600 volts AC (690 volts IEC).

It has a breaking capacity value of 25 kA (480 VAC) and a current rating of 125 amps.

The 140G-G2C3-C15 circuit breaker has a fixed thermal/magnetic trip device with fixed thermal and magnetic trip ratings of 500 amps and 15 amps, respectively.

The breaker will trip immediately when the current flowing through the breaker exceeds the breaker’s setting.

The 140G-G2C3-C15 circuit breaker provides thermal trip action through the use of its bimetallic element, which deflects high currents when they flow through the circuit for extended periods of time.

It also provides magnetic tripping action by means of a solenoid coil which provides a magnetic field proportional to the current applied to the circuit, thereby tripping the circuit when the current exceeds the set trip value.

The 140G-G2C3-C15 circuit breaker has a rated life of 25.000 operations (240 operations per hour) and an electrical life of 8.000 operations (120 operations per hour).

It has 3-pole wiring with line and load side terminals. It comes standard with 1 meter pigtail terminals for mounting internal accessories.

The 140G-G2C3-C15 circuit breaker is DIN rail mounted and is rated IP 20 or IP 40.

The 140G-G2C3-C15 circuit breaker is calibrated for an ambient enclosure temperature of 40 degrees Celsius and can be stored over a temperature range of -40 to 80 degrees Celsius.

The 140G-G2C3-C15 circuit breaker weighs approximately 1.1 kg and has overall dimensions of 76 x 70 x 130 mm.