Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Emerson AMS Trex Device Communicator

Carry Less, Do More – The Single Tool Advantage.

The AMS Trex Device Communicator has been re-engineered for faster performance,

smoother operation, and improved user experience

—with key enhancements and additions including:

• Performance, Speed, and Design:

Noticeably faster response times, greater processing and storage capacity,

and a more intuitive, streamlined user experience.

• NIST Traceability:

Calibrated using standards traceable to the National Institute of Standards and Technology (NIST)

to ensure accuracy of electrical mA current measurements to support maintenance

tasks like 4-20mA loop checks and field device calibrations.

• Bluetooth® connectivity:

Enables seamless wireless integration with Bluetooth devices via the new AMS Device

Configurator App improving maintenance productivity and safety.

• Rugged and Intrinsically Safe Design:

Built to endure harsh industrial conditions—resistant to moisture, extreme temperatures,

and physical shocks, while meeting global Intrinsic Safety standards and wireless approvals.

AMS Trex Interactive 3D Demo Environment

The next generation of the industry’s foremost field device communicator and all-in-one tool is here.

Explore a 3D demo or features like Loop Diagnostics, Bluetooth® capabilities,

Process Loop Troubleshooting, Auto-Sync, Apps, Upgrade Studio and more.

Emerson The Next Generation of AMS Trex Is Here

The Next Generation of AMS Trex Is Here

Building on three decades of expertise in handhelds and intelligent field device management,

AMS Trex continues to deliver the trusted human-centered handheld device communicator,

rugged form factor, long-lasting battery life, and global “go-anywhere” safety certifications

users rely on to commission, configure, diagnose and troubleshoot more than 2500 field devices.

The latest version of the industry’s leading field device communicator has been

redesigned to operate on a modern, faster platform with improved accuracy and device connectivity

including embedded Bluetooth® technology to improve productivity and

safety of field maintenance engineers and technicians.

AMS Trex Interactive 3D Demo Environment

The next generation of the industry’s foremost field device communicator and all-in-one tool is here.

Explore a 3D demo or features like Loop Diagnostics, Bluetooth® capabilities,

Process Loop Troubleshooting, Auto-Sync, Apps, Upgrade Studio and more.

Emerson AMS Trex™ Device Communicator with embedded Bluetooth® connectivity

Power the Loop: streamline maintenance productivity; eliminate the need for

specialized tools (i.e. power supply, loop resistor, ammeter).

Advanced Diagnostics: quickly resolve device configuration issues;

diagnose 4-20mA loops; configure and test control valves inline.

Performance, Speed and Design: Noticeably faster response times,

higher volume load of calculations, and a drastically improved,

intuitive user experience.

NIST Traceability: The new and improved Device Configuration

Plus Module has been redesigned with unmatched mA current accuracy

and calibrated according to traceable, accredited standards as per

the National Institute of Standards and Technology (NIST).

Bluetooth® Connectivity: The next-gen AMS Trex has been

re-engineered with embedded Bluetooth technology, improving maintenance

productivity and safety with seamless integration with Bluetooth devices.

Rugged and Intrinsically Safe Design: Built to withstand harsh

industrial environments; protected against moisture, extreme

temperatures, and physical shocks, meeting global Intrinsic Safety standards.

Field Device Integrity: Ensure online and offline device configurations

are captured and sync’d with AMS Device Manager software.

Emerson S-series IO subsystem

Product Description

The S-series IO subsystem has been redesigned with a focus

on fast assembly and simplified power connections. The system

uses only 24V DC bulk power supplies. All power is connected

to system carriers. Bus connectors have been upgraded to

support additional 12V DC power to the IO cards, allowing

additional power carriers to be inserted anywhere along

the bus.

Carriers mount to standard t-type DIN rail with latches that

require no tools for quick installation. The latches can be

released using a blade screw driver. Simply snap the carrier

to the rail and slide adjacent carriers together to engage the

bus connector.

The I/O carrier supports 8 IO modules. Each card can be

connected to an internal 24V DC bus using the Power Buss

Plugs, or it can be individually powered by using the

Power Terminal Plugs. The internal 24V DC bus is divided into

primary and secondary power, with primary power distributed

to odd numbered slots and redundant power distributed to

even numbered slots using the Power Buss Plugs.

Emerson S-series IO subsystem

Product Description

The S-series IO subsystem has been redesigned with a focus

on fast assembly and simplified power connections. The system

uses only 24V DC bulk power supplies. All power is connected

to system carriers. Bus connectors have been upgraded to

support additional 12V DC power to the IO cards, allowing

additional power carriers to be inserted anywhere along

the bus.

Carriers mount to standard t-type DIN rail with latches that

require no tools for quick installation. The latches can be

released using a blade screw driver. Simply snap the carrier

to the rail and slide adjacent carriers together to engage the

bus connector.

The I/O carrier supports 8 IO modules. Each card can be

connected to an internal 24V DC bus using the Power Buss

Plugs, or it can be individually powered by using the

Power Terminal Plugs. The internal 24V DC bus is divided into

primary and secondary power, with primary power distributed

to odd numbered slots and redundant power distributed to

even numbered slots using the Power Buss Plugs.

GE AT868-2-1-1 Panametrics Ultrasonic Liquid Flow Transmitter

Applications

Le transmetteur de débit pour liquide AquaTrans

AT868 est un système de mesure de débit à

ultrasons complet des liquides suivants:

• Eau potable

• Eaux usées

• Eaux d‘égout

• Eaux de rejet

• Eau traitée

• Eau de refroidissement et de chauffage

• Autres liquides

Caractéristiques

• Mesure du débit non intrusive et économique

• Installation et configuration simples

• Adapté à un large éventail de tailles de conduites

et de matériaux

• Adapté aux conduites à revêtement interne

• Version deux canaux/deux cordes disponibles

• Vitesse d‘écoulement , débit volumétrique et

débit totalisé

• Clavier interne pour la programmation sur site

AT868 Caractéristiques techniques

Performance

Types de fluides

Fluides acoustiquement conducteurs, y compris la plupart

des liquides propres et de nombreux liquides chargés ou

contenant des bulles de gaz. La fraction de vide maximum

dépend du transducteur, de sa fréquence, de la longueur de

la trajectoire et du trajet acoustique des conduites.

Tailles de conduite

• Transducteurs « clamp-on » : 12.7 mm à 7.6 m et plus

• Transducteurs mouillés : 25.4 mm à 5 m et plus

Épaisseur de paroi de conduite

Jusqu‘à 76.2 mm

Emerson S-series Integrated power distribution

Integrated power distribution. Controller and I/O interface

power distribution is integrated into the carriers to reduce and

simplify power and grounding. I/O Carriers have an integrated

shield ground bar to isolate and drain field noise away from

system power. They also provide an integrated redundant 24V

DC bussed field power distribution to reduce installation wiring

and provide fused, isolated power to each I/O interface, using

Power Buss Plugs. Alternatively, the I/O carriers can be ordered

with Power Terminal Plugs to bring dedicated power to each

card, which can be either 24V DC or 120/230V AC. Power Buss

Plugs and Power Terminal Plugs can be mixed on one

I/O Carrier.

A single Power Terminal Plug will come with any 120V AC DI

or 120/230V AC DO card.

Snap In Assembly. All components snap into place without the

use of special tools. The design supports and “easy on” design

to speed up installation and reduce maintenance turnaround.

Carriers snap onto T-DIN Rails. All interfaces and system power

supplies snap into place, eliminating retention screws.

Emerson S-series Horizontal Carriers Modular design allows flexible installation

Benefits

Modular design allows flexible installation. A T- type DIN rail

is all you need to mount the power/controller carrier into place.

Snap the I/O interface carriers to the rail and slide to connect

it to the carrier on the left. Add as many carriers as needed,

or use extender cables to move to a new rail. The DeltaV

system’s modular design approach allows you to add I/O

carriers as you need them.

Allows you to expand online. Additional 8-wide carriers may

be added online as desired. Bus extenders provide dual cabling

for robustness, allowing up to 8 I/O carriers for a total of 64

simplex cards or 32 redundant cards.

Emerson S-series Modular design allows flexible installation

Modular design allows flexible installation. A T- type DIN rail

is all you need to mount the power/controller carrier into place.

Snap the I/O interface carriers to the rail and slide to connect

it to the carrier on the left. Add as many carriers as needed,

or use extender cables to move to a new rail. The DeltaV

system’s modular design approach allows you to add I/O

carriers as you need them.

Allows you to expand online. Additional 8-wide carriers may

be added online as desired. Bus extenders provide dual cabling

for robustness, allowing up to 8 I/O carriers for a total of 64

simplex cards or 32 redundant cards.

Emerson S-series Integrated power distribution

Integrated power distribution. Controller and I/O interface

power distribution is integrated into the carriers to reduce and

simplify power and grounding. I/O Carriers have an integrated

shield ground bar to isolate and drain field noise away from

system power. They also provide an integrated redundant 24V

DC bussed field power distribution to reduce installation wiring

and provide fused, isolated power to each I/O interface, using

Power Buss Plugs. Alternatively, the I/O carriers can be ordered

with Power Terminal Plugs to bring dedicated power to each

card, which can be either 24V DC or 120/230V AC. Power Buss

Plugs and Power Terminal Plugs can be mixed on one

I/O Carrier.

A single Power Terminal Plug will come with any 120V AC DI

or 120/230V AC DO card.

Search for products

Back to Top
Product has been added to your cart