Autronica BS-200M FIRE ALARM CONTROL PANEL

Indicators

• 8 x 40-character alphanumeric display

• Alarm, More Alarms, Pre-Alarm, Remote Call, Remote Call

Response, Fault, Disabled Function, Supervisory Condition, Test

Condition, System Fault, Power, Delayed Activation, Annunciator

Fault, Remote Call Fault, Annunciator Disabled, Remote Call

Disabled, Reduced Detection

• Internal buzzer

Operator Controls

• More Events, Mute, Silence, Reset, Block, Activate Outputs

• Keypad with alphanumeric characters and navigational functions

(Cancel/Back, Enter, directional keys (arrow up/down and

left/right), Function and Select (MultiSelect) key

• Back-lit buttons and text

• Fireman’s key

Autronica BS-200M Applications/Description

Applications/Description

The BS-200M is an integrated Fire Alarm Control Panel for small-to

medium-sized installations. The panel is specifically designed for use in

maritime applications and meets the SOLAS requirements. The panel

serves as a stand-alone panel. A maximum of 8 additional panels can be

freely mixed and connected to the Fire Alarm Control Panel via the RS

485 Panel Bus, including Repeater Panels BS-211. Information Panels

BV-210. Fire Brigade Panels BU-210 and Mimic Drivers BUR-200.

All alarm handling and system features can be configured,

controlled and monitored from the panel.

The panel can accommodate up to a maximum of four detection loops.

The loops support most of AutroSafe detectors, several types of I/O

devices for monitored outputs, open collector outputs, galvanic isolated

inputs and monitored inputs. It has a 5A power module for battery

charging.

The panel is menu operated on a 8-line display, with 40

characters per line.

The Operator Panel (BS-210), which is an integrated part of the

BS-200M panel, can also be mounted separately outside the cabinet.

Autronica BS-200M Features

Features

• SelfVerify-function for automatic testing of detectors

• Automatic setup

• Automatic addressing of detectors

• Four loops

• Built in changeover for primary/emergency mains power

• USB for data transfer to/from memory stick.

• User-friendly display and operator controls

• Back-lit operating buttons. Text display suitable for nighttime operation

• Surface mounting. The integrated panel can be mounted

separately in a 19’’ rack or console

• Designed to meet EN 54 and SOLAS requirements, MED

(“wheel-mark”) and CPD certified

• Complies with environmental conditions of IEC-721-3-3 class 3k5

• Output to VDR and Modbus

Autronica BS-200 Beskrivelse

Beskrivelse

BS-200 er en integreret ABA-central til mindre

og mellemstore installationer. BS-200 er en stand

alone enhed og kan således ikke kobles i netværk

med andre BS-200 centraler. Der kan tilsluttes op

til 8 eksterne paneler af følgende typer:

Repeaterpanel BS-211. Informationspanel BV-210.

Brandmandspanel BU-210 og Mimikdriver BUR-

200. De eksterne paneler tilsluttes via RS485-bus.

Alle ABA-centralens alarmhåndterings- og styre

funktioner kan konfigureres, overvåges og styres

fra centralen. Panelet er menudrevet og udstyr-

et med et 8-linjers display med 40 tegn pr.

linje.

ABA-centralen kan styre to detektorsløjfer (kan

udvides til fire detektorsløjfer ved tilkøb af udvid-

elseskort), og der kan monteres op til 127 sløjfe

enheder på hver detektorsløjfe. Sløjferne under

støtter de fleste analoge Autronica detektorer;

herunder optiske detektorer, termodetektorer,

multi- og flammedetektorer samt en lang række

I/O-enheder. ABA-centralen er endvidere forsynet

med en 5A strømforsyning dedikeret til opladning

af nødstrømsbatterier.

Betjeningspanelet kan enten fungere som en in-

tegreret del af BS-200 ABA-centralen eller kan

monteres op til 1.000 kabelmeter væk fra selve

centralkabinettet.

Indikatorer

•   8 x 40 tegns alfanumerisk display

•   Alarm, Flere alarmer, Forvarsel, Brand-

væsen, Brandvæsen bekræftet, Fejl,

Udkobling(er), Teknisk varsel, Test,

Systemfejl, Netspænding, Forsinket

aktivering, Alarmvarslingsfejl, Alarm-

overførsel udkoblet, Brandvæsen ud-

koblet

•   Intern summer

Autronica BRANDALARMCENTRAL BS-200

Egenskaber

•   SelfVerify® funktion til automatisk test af

detektorer

•   Plug & Play autokonfiguration af centralen

•   To detektorsløjfer (kan udvides til fire)

•   Overførsel af konfigurationsdata til/fra cen-

tralen via USB

•   Brugervenlige betjeningsfunktioner og display

•   Baggrundsbelyste betjeningstaster og display

•   Betjeningspanel overflademonteres eller

monteres planforsænket

•   Designet i henhold til EN 54. CE godkendt

•   Opfylder miljøstandard i IEC-721-3-3 klasse 3k5

Betjeningsfunktioner

•   Flere Hændelser, Afstil Summer, Afstil

klokker, Forlæng forsinkelse, Aktiverudgange

•   Tastatur med navigationsfunktioner

(Annuler/Tilbage, Enter, retningstaster

(Pil Op/Ned/Venstre/Højre), Funktions-

og valgtast (flere valg)

•   Baggrundsbelyste betjeningstaster ogtekst

•   Brandmandsnøgle

Autronica FIRE ALARM CONTROL PANEL – BS-200

Application/Description

The BS-200 is an integrated fire alarm control panel for small to

medium sized installations. The panel serves as a stand-alone panel. A

maximum of 8 additional panels can be freely mixed and connected to

the Fire Alarm Control Panel via the RS-485 Panel Bus, including

Repeater Panels BS-211. Information Panels BV-210. Fire Brigade Panels

BU-210 and Mimic Drivers BUR-200.

All alarm handling and system features can be configured, controlled

and monitored from the panel.

The standard panel is prepared for two detection loops, but it can

accommodate up to a maximum of four detection loops using the loop

extension pack BSD-200A/PACK*. The loops support most of AutroSafe

detectors, several types of I/O devices for monitored outputs, open

collector outputs, galvanic isolated inputs and monitored inputs. It has

a 5A power module for battery charging.

The panel is menu operated on a 8-line display, with 40 characters per

line.

The Operator Panel (BS-210), which is an integrated part of the BS-200

panel, can also be mounted separately outside the cabinet.

Indicators

• 8×40 character alphanumeric display

• Alarm, more alarms, Pre-alarm, Remote call, Remote

Call Response, Fault, Disabled Function, Supervisory

Condition, Test condition, System Fault, Power, Delayed Activation,

• Annunciator Fault, Remote Call Fault, Annunciator

Disabled, Remote Call Disabled, Reduced Detection

• Internal buzzer

Autronica BS-200 Features

Features

• SelfVerify function for automatic testing of detectors

• Automatic setup

• Automatic addressing of detectors

• Two loops

• USB for data transfer to/from memory stick

• User-friendly display and operator controls

• Backlit operating buttons. Text display suitable for night

time operation

• Surface mounting

• Designed to meet EN 54 requirements and conforms to CE

standards

• Complies with environmental conditions of IEC-721-3-3 class 3k5

Operator Controls

• More Events, Mute Panel, Silence, Reset, Prolong

Delay, Activate Outputs

• Keypad with navigational functions (Cancel/Back,

Enter, directional keys (arrow up/down and

left/right)), Function and Select (MultiSelect) key

• Backlit buttons and text

• Fireman’s key

MITSUBISHI ELECTRIC INVERTER FR-D700 Global standard

Leading life check function

•Degrees of deterioration of main circuit capacitor, control circuit

capacitor, and inrush current limit circuit can be monitored.

•Trouble can be avoided with the self-diagnostic alarm*4 that is

output when the life span is near.

Password function

Registering a 4-digit password can limit

parameter read/write.

It is effective for parameter setting protection.

FR-D700 Series

Low cost micro VFD with Mitsubishi Electric quality.

• Simple to use: The FR-D700 is perfect for a wide

range of applications

• Simple to set-up: The integrated digital setting dial

with display makes configuration fast and easy

• Simple operation: Control remotely or with the

built-in digital control

• Simple to choose: Low cost and with Mitsubishi

Electric quality ensuring long operation life

• Capacity: From 1/8 to 20 HP

• Safety stop function: Meets EN954-1 Category 3 and

IEC60204-1 Stop Category 0

• Integrated brake chopper circuit

• MODBUS RTU: Included as standard via the

RJ45 port

• 150% torque at 1Hz and 200% torque at 3Hz using

General-purpose Magnetic Flux Vector Control

• Optimum Excitation Control: For increased energy

savings when motor is not loaded

• Frequency search function: Catch a spinning load

• Dancer control: Allows position signal to control

roll tension

• Password function: For parameter setting

protection

• Internal diagnostics function: For monitoring

status of critical components

• RoHS compliant

• 10 year maintenance free design

MITSUBISHI ELECTRIC FR-D700 series Safety stop function

Safety stop function

The FR-D700 series is compliant to the EU Machinery Directive without the addition of

previously required external devices.

Operation of an external Emergency Stop device results in a highly reliable

immediate shutoff of the D700’s output to the motor.

Spring clamp terminal (control circuit terminal)

•Easy wiring

Wiring is completed only by inserting wires treated

with blade terminal (max. diameter 1.5mm)

Capable of wiring without a blade terminal.

•Highly reliable

Spring structure in terminal contact section inside prevents contact fault

by vibration.

•Maintenance is unnecessary

Screw retightening is unnecessary.

Long-life design

•The design life of the cooling fan has been extended to 10

years*1. The life of the fan can be further extended utilizing the

it’s ON/OFF control.

•The design life of the capacitors has been extended to 10 years*1*2

by adopting a capacitor that endures about 5000 hours at 105°C

surrounding air temperature.

ABB SCC-C Sample gas cooler

Sample gas inlet conditions

Sample gas flow

1 × 250 l/h (WT250) or 1 × 125 l/h (WT125) or 2 × 125 l/h

(WT125), based on a sample gas pressure of pabs =

100 kPa (1 bar) and 25 °C

Note

Only the WT125 is used in the AO2000 system

Sample gas inlet temperature

• Standard design: maximum 140 °C

• CSA Class I, Division 2 design: maximum 135 °C

• ATEX Zone 2 design: maximum 130 °C

Sample gas inlet dew point

max. 70 °C,

max. 60 °C for WT250 with sample gas flow > 200 l/h