Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Beckhoff The main features of the CX8200 device series

The main features of the CX8200 device series include:

• high-performance 1.2 GHz Arm® Cortex®-A53 CPUs with two cores

• 1 GB LPDDR4 RAM

• USB 3.0 interface for wireless and cellular communication

• built-in capacitive 1-second UPS

• TwinCAT NC PTP available

• platform level 20 in TwinCAT 3

The boot and storage medium is an interchangeable, industry-standard microSD

card, which can be accessed via a covered slot. This is used to store not only the

operating system, but also TwinCAT and user projects. As a result, hardware can

be replaced rapidly in the case of service, and software updates can be performed

on site by simply replacing the microSD card. Beckhoff RT Linux® is used as

operating system.

The built-in capacitive 1-second UPS ensures secure backup of persistent application

data on the microSD card, and the date and time are buffered via a maintenance-free

capacitor.

Users benefit from powerful object-oriented programming capabilities and a wide

range of software components (Functions) from the TwinCAT 3 portfolio.

They are cost-optimized for use on the CX8200 device platform. The TwinCAT

automation software turns the CX8200 system into a high-performance PLC and

motion control system. Proven features of the CX8000 series are also proviced,

such as the automatic E-bus/K-bus recognition as well as the extended operating

temperature range between -25 and +60°C for application in climatically demanding

situations.

With the CX8200 series, Beckhoff offers a compact controller that supports a wide

range of bus systems in addition to EtherCAT. The CX8210 EtherCAT slave, the

CX8280 for serial protocols, and the CX8290 for different Ethernet protocols are

available as interfaces. The fieldbus and communication system support will be

extended, e.g. PROFINET, CANopen, PROFIBUS.

Beckhoff CX82xx | Embedded PC series, compact PLC

Compact PLC with Arm® Cortex®-A53 and Beckhoff RT Linux®

The CX8200 Embedded PC series is a further development of the existing

CX8100 series and combines higher computing power in a compact format

for a wide range of automation tasks. Equipped with a faster, modern Arm®

Cortex®-A53 processor with 64 bit architecture, users benefit from a

significantly higher clock frequency of 1.2 GHz and two cores for compact

controls. The multi-core CPUs allow PLC projects to be distributed to several

cores for significantly enhanced performance.

The CX8200 Embedded PC series forms the link between the CX7000 and

CX8100 series on one hand, and the CX9240 on the other, opening up whole

new application areas and possibilities thanks to the more modern CPU and

the same low power consumption. A particular highlight of the new series is

the significantly faster 1 Gbit Ethernet interface and the expansion of the

main memory to a larger 1 GB LPDDR4 RAM, which represents double the

main memory compared to the predecessor series. What’s more, the series

also offers a USB 3.0 interface that can be used for connecting wireless and

cellular components or additional USB storage media.

Beckhoff CX8191 | Embedded PC with Arm® Cortex®-A9 and BACnet/IP

The CX8191 is a control system with a switched Ethernet port.

It supports the BACnet protocol. E-bus or K-bus terminals can

be attached as required; the CX8191 automatically recognizes

the type of I/O system connected during the start-up phase.

The control system is programmed with TwinCAT 3 via the fieldbus

interface or the additional Ethernet interface. TwinCAT 3 licenses

must be ordered via the TwinCAT 3 price list. The BACnet license

is already installed on the device and does not need to be ordered

separately.

BACnet (Building Automation Control Network) is a standardized,

manufacturer-independent communication protocol for building 

automation. Areas of application include HVAC, lighting control,

safety and fire alarm technology.

In conjunction with the EL6861 BACnet-MS/TP terminals, the CX8191

can act as a router to MS/TP networks including support for several

MS/TP networks.

Further TwinCAT 3 functions and protocols are available for the CX8191.

for example OPC UA, MQTT, Modbus TCP or Modbus RTU.

All functions and protocols can be found in the TwinCAT product finder

if you set the filter under TwinCAT 3 platform level to P20.

The CX8191 is a virtually universal device that can be used very flexibly,

from control tasks through to gateway functions.

Beckhoff CX7000 | Embedded PC with Arm® Cortex®-M7 and integrated I/Os

The CX7000 Embedded PC has an Arm® Cortex®-M7 single-core

processor with 480 MHz. In the basic configuration, the CX7000

has a slot for a microSD card and an Ethernet interface.

As a special feature, the CX7000 series has eight integrated multi

functional inputs as well as four integrated multi-functional outputs.

E-bus or K-bus terminals can be attached as required; the CX7000

automatically recognizes the type of I/O system connected during

the start-up phase. The control system is programmed with TwinCAT

3 via the Ethernet interface.

LENZE I/O system 1000

Compactstructure

• Slimline design

• 8connectionpoints in a width ofjust 12.5 mm

• Tried-and-tested tension spring technology

• Stair-step shaped, space-saving wiring level

• Consistent separation of electronics and the wiring level

• Upto64 modulescanbeconnected

• Automaticconnection via the backplane bus

Performance and robustness

• Gold-plated contacts guarantee a secure connection between the

modules

• Fault-tolerantprotocolssecuremaximumavailability–eveninthe

event of individual frame errors

• Thelargebandwidthof48 MBits/sallowsextremelyfastresponse

times without telegram overheads

LENZE I/O system 1000 User-oriented connection technique

User-oriented connection technique

The “internals” of the I/O system are also user friendly down to the

last detail: the I/O compound module, consisting of terminal block

with backplane bus connection and electronics protected against

polarity reversal, has a modular structure. This allows a defective

electronic module to changed when maintenance work needs to be

performed without the wiring from the base module having to be

disconnected.Serviceengineersknowthatthiseliminatesacommon

sourceoferrors–incorrectwiring.Thesteppeddesignoftheconnec

tionlevelalsooffersadvantages,includingtensionspringconnection

technology and permanent wiring, which has proven itself on

standardterminalsforyears.Forthewiringitself,asimplescrewdriver

is sufficient. The simple and clear system of labelling and wiring for

thenewsystemalsomakesitabreezetocombinemodulestocreate

complete stations. The integrated backplane bus allows up to

64 modulestobeconnectedinanydesired sequence bysimply

plugging them in without the need for any wiring.

LENZE I/O system 1000 Product information

Product information

Complies with the strictest requirements

TheavailabilityofEtherNet/IP-basedbussystemslaysthefoundations

for newautomation concepts in the field of machine and systems

engineering — the performance limits of established bus systems

are then eliminated.

The L-force I/O system 1000 offers highly deterministic control of

inputandoutputmodules,whichalsoincludesimportingtouchprobe

inputs,suchasthoserequiredforsynchronisedmovementsinclocked

productionprocesses.Aminimuminternalcycletime,incombination

withatimestamp,ensuresthattheI/Osystem 1000itselfmeetsthe

strictest speed requirements here. As such, it is also suitable for use

in realtime-based architectures.

Attheveryfirstglance,thesystemimpresseswithitsslimlinedesign,

aswellasitsclearlystructuredlabellinganddiagnosticsconcept.The

I/O modules, which offer space for 8 connections, require just

12.5 mmofspaceontheconventionalDINrail.

Schneider Electric Saitel offers many key benefits

Benefits

Schneider Electric Saitel offers many key benefits such as:

• Simplicity of implementation and operation.

• Flexibility of a product opened to a wide variety of SCADA systems and to all communication

medium types.

• Large storage capabilities: the advanced head unit can be ordered with an optional compact

flash interface in case large amounts of storage memory are required.

• Powerful yet cost effective.

• Straightforward commissioning

• Open communication structure

• Remote access by operating program

• User-friendly

• Easily configurable

Applications

Distribution & Transmission Networks:

• SAS for HV & MV Substations

• SAS – Gateway – Station Level

• SAS – Bay Control

• Feeder Automation & Pole-top RTU

• Communications Front-End

Generation Sector:

• Field Solar Controller

• Solar Plant Comm. Front-End

• Hydro Power Plant Automation

• Hydro Group Automation

• Process Control

Railway:

• Control substations and Autotransformers Centers

• Catenary control

• Communications Front-End

Schneider SAITEL Remote Terminal Unit & Controller

SAITEL Remote Terminal Unit & Controller

Compact, scalable, powerful communications

Part of PowerLogic™

The high-performance, versatile, scalable and compact platform for secure automation

and communication applications.

Features

pSaitel is a highly-evolved field device, offering a solid and powerful platform for data

acquisition, communication, automation and IED integration, including backplane and

DIN rail based solutions.As a remote terminal unit, bay controller or protocol converter,

Saitel is the compact solution to countless applications installed in demanding 

electromagnetic conditions.In addition to the traditional input/output (I/O) management,

Saitel acts as a powerful communication gateway, an advanced measurement center and

a fast automation processor.Based upon an extendable distributed architecture and

featuring enhanced functionality and power, Saitel Family offers:/pp /ppThe ability to

monitor and control thousands of I/O points./pp /ppOperational redundancy for power

supply, CPU, communications channels, or for the entire system (supporting automatic

failover with hot-swap)./pp /ppExtensive library of standard and legacy protocols for

information exchange between multiple masters and RTU./pp /ppInput/Output acquisition

modules with signal conditioning and integrated time synchronization (1 ms) and

independent time stamping./pp /ppIEC 61850 technology that is certified as Class A by

the independent testing laboratory KEMA for both IEC 61850 server and client interfaces.

Cybersecurity features and functions can support a utility’s NERC Critical Infrastructure

Protection (CIP) compliance.

Schneider The SM_DO16R module includes

The SM_DO16R module includes:

• 16 independent free-contact digital outputs (DO) in two independent blocks. Each DO can be

configured as:

o Single: pulsed (fixed time) or preset (latched).

o Double: pulsed or preset.

• All DO are SPST (Single Pole Single Throw) or NO (Normally open).

• External polarization of DO for each block. According to the P/N, DO signals will be polarized

using 24 VDC or 48 VDC.

• Polarization level is monitored for each block.

• An advanced command safety mechanism is used to control field operation.

• Autocheck of DOs every time that the polarization is reset.

• Control by external watchdog for unsafe situations. The module goes to a safe mode

(commands are blocked) if certain conditions are not met.

• Address and communication rate in the bus are setting using microswitches located on the rear

side.

• 20 LED indicators giving information about the status of the module and each DO.

• The software in the module can be upgrade remotely, from the CPU.

• Isolation of 2.2 kV between field connectors and the controller block.

This module implements hot-swapping function, that is, it can removed and installed on the

backplane while the RTU is working without affecting the proper functioning of the system.

The diagram below illustrates the functional blocks integrated in the SM_DO16R module:

• I/O to the bus: Connection to the bus in the backplane to share information with the CPU.

• LEDs: There are 20 LED indicators on the module’s front side which provide information about

the module and the output signals.

• Synchronization: SM_DO16R is synchronized via a message received from the CPU that

includes information about the time. Therefore, the module will be synchronized with the

synchronization source accuracy used for the CPU.

Search for products

Back to Top
Product has been added to your cart