Welcome to the official website of CNIACS Automation Technology Co., Ltd!

GE The EnerVista suite is an industry-leading

EnerVista Software

The EnerVista suite is an industry-leading set

of software programs that simplifies every

aspect of using the C30 relay. The EnerVista

suite provides all the tools to monitor the status

of the protected asset, maintain the relay, and

integrate information measured by the C30 into

DCS or SCADA monitoring systems. Convenient

COMTRADE and SOE viewers are an integral part

of the UR setup software included with every UR

relay, to carry out postmortem event analysis

and ensure proper protection system operation.

EnerVista Launchpad

EnerVista Launchpad is a powerful software

package that provides users with all of

the setup and support tools needed for

configuring and maintaining Multilin products.

The setup software within Launchpad allows

for the configuration of devices in real-time

by communicating using serial, Ethernet, or

modem connections, or offline by creating

setting files to be sent to devices at a later time.

Included in Launchpad is a document archiving

and management system that ensures critical

documentation is up-to-date and available

when needed. Documents made available include:

• Manuals

• Application Notes

• Guideform Specifications

• Brochures

• Wiring Diagrams

• FAQs

• Service Bulletins

GE EnerVista Launchpad is a powerful software package

EnerVista Launchpad

EnerVista Launchpad is a powerful software

package that provides users with all of

the setup and support tools needed for

configuring and maintaining Multilin products.

The setup software within Launchpad allows

for the configuration of devices in real-time

by communicating using serial, Ethernet, or

modem connections, or offline by creating

setting files to be sent to devices at a later time.

Included in Launchpad is a document archiving

and management system that ensures critical

documentation is up-to-date and available

when needed. Documents made available include:

• Manuals

• Application Notes

• Guideform Specifications

• Brochures

• Wiring Diagrams

• FAQs

• Service Bulletins

Multilin™ C30 Controller LAN Redundancy

Direct I/O Messaging

Direct I/O allows for the sharing of high-speed

digital information between multiple UR

relays via direct back-to-back connections or

multiplexed through a standard DS0 multiplexer

channel bank. Regardless of the connection

method, direct I/O provides continuous real-time

channel monitoring that supplies diagnostics

information on channel health.

Direct I/O provides superior relay-to-relay

communications that can be used in advanced

interlocking, generation rejection and other

special protection schemes.

• Communication with up to 16 UR relays

in single or redundant rings rather than

strictly limited to simplistic point-to-point

configurations between two devices

• Connect to standard DS0 channel banks

through standard RS422. G.703 or IEEE

C37.94 interfaces or via direct fiber optic

connections

• No external or handheld tester required to

provide channel diagnostic information

LAN Redundancy

Substation LAN redundancy has been

traditionally accomplished by reconfiguring

the active network topology in case of failure.

Regardless of the type of LAN architecture (tree,

mesh, etc), reconfiguring the active LAN requires

time to switchover, during which the LAN is

unavailable. UR devices deliver redundancy as

specified by PRP-IEC 62439-3. which eliminates

the dependency on LAN reconfiguration and the

associated switchover time. The UR becomes a

dual attached node that transmits data packets

over both main and redundant networks

simultaneously, so in case of failure, one of the

data packets will reach the receiving device with

no time delay.

GE The C30 provides advanced communications technologies

Communications

The C30 provides advanced communications

technologies for remote data and engineering

access, making it easy and flexible to use and

integrate into new and existing infrastructures.

Direct support for fiber optic Ethernet provides

high-bandwidth communications allowing

for low-latency controls and high-speed

file transfers of relay fault and event record

information.

The available three independent

Ethernet ports, redundant Ethernet option

and the embedded managed Ethernet switch

provide the means to create fault tolerant

communication architectures in an easy,

cost-effective manner without the need for

intermediary communication hardware.

The C30 supports the most popular industry

standard protocols enabling easy, direct

integration into DCS and SCADA systems.

• IEC 61850 Ed. 2 with 61850-9-2 support

• DNP 3.0 (serial & TCP/IP)

• Ethernet Global Data (EGD)

• IEC 60870-5-103 and IEC 60870-5-104

• Modbus RTU, Modbus TCP/IP

• HTTP, TFTP, SFTP and MMS file transfer

• SNTP and IEEE 1588 for time synchronization

• PRP as per IEC 62439-3

Multilin™ C30 Role Based Access Control (RBAC)

Cyber Security –

CyberSentry UR

CyberSentry UR enabled UR devices deliver full

cyber security features that help customers to

comply with NERC CIP and NIST® IR 7628 cyber

security requirements.

wThis software option delivers the following core features:

AAA Server Support (Radius/LDAP)

Enables integration with centrally managed

authentication and accounting of all user

activities and uses modern industry best

practices and standards that meet and exceed

NERC CIP requirements for authentication and

password management.

Role Based Access Control (RBAC)

Efficiently administrate users and roles within

UR devices. The new and advanced access

functions allow users to configure up to five

roles for up to eight configurable users with

independent passwords. The standard “Remote

Authentication Dial In User Service” (Radius) is

used for authentication.

Event Recorder (Syslog for SEM)

Capture all cyber security related events within

a SOE element (login, logout, invalid password

attempts, remote/local access, user in session,

settings change, FW update, etc), and then

serve and classify data by security level using

standard Syslog data format. This will enable

integration with established SEM (Security Event

Management) systems.

GE The C30 performs comprehensive device health diagnostic

Monitoring and Metering

The C30 provides high resolution measuring

of the status of external devices wired to its

contact inputs. The changing of a contact input

status can be measured

and time-stamped with a 0.5ms resolution,

making the C30 ideal for bay or substation SOE

recording.

Fault and Disturbance Recording

The advanced disturbance and event recording

features within the C30 can significantly reduce

the time needed for postmortem analysis

of power system events and the creation of

regulatory reports.

Advanced Device Health Diagnostics

The C30 performs comprehensive device health

diagnostic tests at startup and continuously

during run-time to test its own major functions

and critical hardware. These diagnostic tests

monitor for conditions that could impact security

and availability of protection, and present device

status via SCADA communications and front

panel display. Providing continuous monitoring

and early detection of possible issues help

improve system uptime.

GE The C30 incorporates advanced automation features

Monitoring & Metering

• Advanced recording capabilities with highcapacity

event recorder, configurable and

extended waveform capture and data logger

• Metering: current, voltage, power, energy,

frequency, and harmonics

Protection and Control

As part of the UR family of Protection & Control

devices, the Multilin C30 offers a high degree

of modularity in its design and functionality,

providing superior performance while meeting

the toughest requirements of the marketplace.

Control, automation, I/O expansion and data

gathering are ideally suited for the C30 in the

following applications:

• Bay control

• Substation automation

• Remote I/O

Advanced Automation

The C30 incorporates advanced automation

features including powerful FlexLogic™

programmable logic, peer- to-peer

communications and SCADA capabilities that

far surpass what is found in the average PLC or

controller. The C30 integrates seamlessly with

other UR relays to extend the I/O capabilities and

perform complete bay management and control.

FOXBORO The FBM is a general purpose Ethernet hardware module


I/O Driver

The FBM is a general purpose Ethernet hardware module that can be loaded with different software

drivers.

These drivers configure the FBM to recognise the specific protocol used by the device.

Some of these software drivers are standard products. Other custom drivers can be developed to meet

specific needs.

These drivers are dynamically downloaded to the FBM233 with software code

specifically designed to interface with the protocols of third party devices.

The configuration steps and software requirements for each driver are specific to the device integrated

into the system.

Ethernet Link Setup

Data communication between the FBM233 and field devices takes place via the RJ-45 interface on the

front of the FBM233 module.

The RJ-45 connector of the FBM233 can be connected to the field device via a hub or an Ethernet switch.

The FBM233 connects to an Ethernet switch or hub to communicate with one external device or up to 64

external devices.

FOXBORO Key features of the FBM233 include

Functional Features

Key features of the FBM233 include

– Redundant 10 Mbps or 100 Mbps Ethernet network transfer rates to and from field devices

– Communication with up to 64 field devices

– Downloadable I/O software drivers from available protocol libraries

– Up to 2000 DCI block connections

– Integration of field device data into the Foxboro DCS control database using an Ethernet connection

– Field Installation

– G3 rated (harsh) environments.

Configurator

The FDSI Configurator sets up the FBM233 ports and XML-based device profiles.

The Port Configurator makes it easy to set communication parameters

(e.g., Dynamic Host Configuration Protocol (DHCP), IP address) for each port.

The Device Configurator is not required for all devices, but when it is,

it can configure device-specific and point-specific considerations

(e.g., scan rate, address to which data is to be transferred,

and amount of data to be transferred in a single transaction).

ABB Model DHH805 Standard delivery items


Connections

— to the transmitter: 2 standard banana jacks,

suitable for 1.5 m (5 ft) leadset with insulated minigrabbers

and alligator clips (provided).

— to the PC: USB port (type B) suitable for cable (provided),

to allow software and DD upgarde and to use the DHH805

in modem functionality.

— to the battery recharger: 5 mm dia. socket with inner pin

as positive pole.

Weight (without accessories)

0.95 kg approx (2 lb)

Add 450g (1 lb) for carrying case.

Packing

Carton including all accessories and documentation.

Standard delivery items

DHH805A is delivered in a hard plastic case including

— battery assemblies (rechargeable and disposable versions)

— power adapter/battery recharger with universal plugs

— elastic handle strap and rubber shell

— USB cable and leadset to the transmitter with minigrabbers

— soft carry bag with adjustable shoulder strap

— DVD with PC-Tool software and HART DD library

Search for products

Back to Top
Product has been added to your cart