Welcome to the official website of CNIACS Automation Technology Co., Ltd!

ABB VistaSTAR with PGC5000

Features of STAR Server

– Store data for PGC5000 (Version 4)

– Stores all analyzer data including every chromatograph

and report for a minimum of 30 days

– Trending and archiving of data values from multiple devices

in the same trend plot

– Batch reprocessing of PGC5000 chromatograms

– Run Repeatability

Features of STAR Client

– View all data stored in STAR Server

– Plant overview

–Application launcher

– User preferences

– Import / Export trends

– Reprocess PGC5000 Chromatograms

– Consistent report viewing across multiple devices

ABBVistaSTAR is the next generation of data system

Measurement made easy

VistaSTAR is the next generation of data system interface

software designed to unify the legacy generation

instrumentation that we have in the field with the current

PGC5000 Series of instrumentation for a complete analyzer

asset optimization and plant monitoring tool. VistaSTAR data

system uses many of the existing instrumentation and

applications found in VistaNET. VistaSTAR introduces two

additional applications; the STAR Client and the STAR Server,

and adds several new features to our flagship Process Gas

Chromatograph – PGC5000 Version 4.

The STAR Client is a windows based application that provides

a centralized launch point for the legacy VistaNET applications

and current versions of Remote Client. It also allows the user

to view trends and chromatograms that are historized in the

STAR Server.

The STAR Server is an appliance server that saves data

from PGC5000 (Version 4), PGC2000. RVP, and Multiwave.

The STAR Server has three different licensing levels 1-5.

1-15. 1-250. If the 1-250 level is purchased, a 12 Terabyte

hard drive array is supplied in order to guarantee maximum

system availability.

The PGC5000 analyzer ATEX Directive 2014/34/EU, annex II

ATEX Directive 2014/34/EU, annex II

The PGC5000 analyzer “must be so designed and

constructed as to prevent ignition sources arising,

even in the event of frequently occurring

disturbances or equipment operating faults, which

normally have to be taken into account”. The design

of the analyzer is capable of functioning within the

established operational parameters and of ensuring

a high level of protection necessary for the intended

classified Ex zone 1 area.

The notified body LCIE examined the internal components of the PGC5000

and approved the analyzer as Ex ‘py’ for a zone 1 area:

•    The EC-type examination of the PGC5000 series

analyzer and the IEC Ex test report first evaluated

the internal components to Part 15 of the

harmonized conformity standard IEC60079 (Ex ‘n’)

as either being non-sparking, energy limited or

temperature limited to below the specified

temperature class (ref: certificates EC-type LCIE

09ATEX 1017X and IECEx LCI09.0010X).

•    The EC-type examination of the PGC5000 series

analyzer and the IEC Ex test report then evaluated

the pressurization protection of the enclosure to

part 2 of the harmonized conformity standard

IEC60079 (Ex ‘p’) as being suitable for zone 1 area

without electrical power interlock to the

pressurization system (ref: certificates EU-type

LCIE 09ATEX 3006X and IECEx LCI09.0010X).

ABB This simple pressurization technique for the PGC5000

PGC Certification

This simple pressurization technique for the

PGC5000 is considered an improvement to the

process gas chromatograph analyzer by allowing for

a continual operation without possible disruption

caused by interlocking the electrical power to the

pressurization system. When operated in a zone 1

area, the user of the PGC5000 analyzer is simply

responsible for:

•    Operating the analyzer within the manufacturer’s

established parameters, as described in the

product manuals and the CE conformity

declaration’s special conditions for safe use

•    Providing a reliable supply of protected air for the

enclosure purge and pressurization system

•    Monitoring the alarm state of the pressurization

system in normal operation

•    Responding to the alarm condition of the

pressurization system, which may require

restoring the supply of protected air or the

removal of electrical power and proper isolation

of remaining hazardous live circuits if the area is

potentially hazardous

ABB Zone 2 certification by design

Introduction

For a classified Ex zone 1 area, the rationale behind

this “Zone 2 by design” analyzer is that the analyzer

must remain safe when operated in an abnormal

condition. In the event of a fault, the PGC5000

provides continual protection:

•    Should a failed component become ignition

capable, the pressurization system prevents the

components from being exposed to flammable

gases or vapors.

•    Should a failed pressurization system expose the

internal components to flammable gases or

vapors, the analyzer’s alarm provision will alert the

user of the failure.

Neither of these single faults would present a

hazard to the potentially explosive atmosphere;

therefore, electrical power interlock is not required

for this type of pressurization protection. Enclosure

doors are not required to be interlocked so that the

electrical supply is disconnected automatically

when doors are opened. The requirement is simply

an alarm provision since there are no hazards inside

the enclosure when in normal operation.

The zone 1 certified PGC5000 analyzer offers simple

pressurization protection, commonly referred to as

Ex ‘py’ or “Y-purge”. This enclosure pressurizing

technique is made possible by ensuring that the

internal components within the analyzer are not

capable of causing an ignition in normal operation,

thus allowing for a reduction in classification within

the protected enclosures from zone 1 to zone 2.

HONEYWELL BW™ RIGRAT Transportable Multi-gas Area Monitor

FEATURES AND BENEFITS

WIRELESS SAFETY PERIMETER

Position several Honeywell BW™  RigRat monitors to form a wireless safety perimeter.

REMOTE MONITORING 

Use with Honeywell’s remote monitoring software to see gas readings, location and other data

from any device with an internet connection — for fast, informed decisions. 

Add an optional noise  sensor or meteorological sensor.

OTHER HONEYWELL BWTM RIGRAT FEATURES:

• Line power for extended runtime in the field

• I/O ports providing additional input capabilities and local executive activation. 

• Inert mode that prevents alarm in normal ambient air. 

• Large, easy-to-read display

• Rugged, weatherproof design, with optional protective cage

HONEYWELL TOUCHPOINT™ PLUS COMPATIBLE

Use with the Honeywell Touchpoint™ Plus controller for visibility on

Honeywell BW™ RigRat monitors and workers’ personal detectors.

HONEYWELL BW™ RIGRAT TECHNICAL SPECIFICATIONS

HONEYWELL BW™ SOLO FEATURES AND BENEFITS

FEATURES AND BENEFITS

For even more time-saving convenience

— plus remote visibility on alarms

— choose the wireless version.

And manage it from your smartphone.

Pair the wireless Honeywell BW™ Solo with our Safety Communicator mobile

 app and detector readings are sent instantly to Honeywell’s real-time monitoring software

– Honeywell Safety Suite Real Time

– which can be accessed from any device with an internet connection, and get remote visibility on worker

safety and location.

You can also use the wireless Honeywell BW™ Solo to share gas data with the desktop software — no

dock required.

Other Honeywell BW™ Solo features: 

• Option to activate IntelliFlash™ or non-compliance flash

• Ability to assign detectors to workers and locations

• Easy-to-read display for multiple languages

• Data logging with rolling 24-hour peak reading

Honeywell BWTM Solo Technical Specifications

Honeywell BW™ Solo Compatible with IntelliDoX

Honeywell BW™ Solo is:

 • The easiest single-gas detector to service, with no need to take it apart to replace sensors,

batteries and sensor filters. That means long life and low cost.

 • Complete with an extensive selection of sensor options. Count on comprehensive detection,

whether you’re monitoring for common or exotic hazards.

 • The first single-gas detector with the 1-Series sensor for CO, H2S, O2and CO2

 . That means high accuracy, lower costs and faster sensor response time for the gases you monitor most

often.

 • Compatible with IntelliDoX.

Save time and centralize data with automated bump testing, calibration and instrument management.

Use IntelliDoX docking stations with Honeywell SafetySuite Device Configurator software

to maintain and monitor your entire fleet from practically anywhere.

Honeywell Touchpoint Plus Providing Ease and Efficiency 

Providing Ease and Efficiency 

• Quick and easy installation, configuration, setup, and maintenance

 • Easy diagnostics, data, and reporting

 • Minimum training time

 • Large color touchscreen LCD

 • Multilingual functionality

 • Green-yellow-red status at a glance

The signature feature of the Touchpoint line is a user-friendly touchscreen interface,

which the Touchpoint Plus takes to a new level. With this unique interface,

it’s easier than ever to see the status of your system at a glance

– maximizing the time you have to make the right decisions.

The intuitive, multilingual interface simplifies operation and reduces training requirements.

The full-color stoplight-style status indication provides clarity from a distance too.

Touchpoint Plus features a comprehensive set of outputs as standard,

including common alarms and dedicated drives for remote audiovisual indicators.

Its modularity enables you to customize your system to meet your specific application requirements.

Selecting the right detector for use with your controller can deliver significant

savings in startup costs and ongoing operations. 

Honeywell Touchpoint Plus Flexible Capabilities

Flexible Capabilities

 • Compatible with the full range  of Honeywell gas detectors

 • Powered audiovisual alarms  simplify field installation

 • Configuration includes easy  grouping and voting alarm logic without specialist knowledge

 • Next-generation compatibility 

• Optional Modbus output for integration with a higher level system

The full-color stoplight-style status indication provides clarity from a distance too.

Touchpoint Plus features a comprehensive set of outputs as standard,

including common alarms and dedicated drives for remote audiovisual indicators.

Its modularity enables you to customize your system to meet your specific application requirements.

Selecting the right detector for use with your controller can deliver significant

savings in startup costs and ongoing operations. 

Our global partner network and dedicated application specialists are

able to help you make the right choices for your industry.

With everything at your fingertips, you can take ownership of your system

and operate it with confidence, helping to ensure the safety of your people and the productivity of your

site.

Search for products

Back to Top
Product has been added to your cart