Welcome to the official website of CNIACS Automation Technology Co., Ltd!

VMIVME-2510B 64-bit TTL Digital Input/Output Features

Functional Features

Compatibility VMEbus-compliant dual high-profile I/O connector type: Dual 64-pin connector, DIN 41612

I/O Organization: Eight I/O ports; eight bits wide.

Addressable to any address within the short supervisory or short unprivileged I/O mapping.

Addressing scheme:

Eight ports can be individually addressed on 8-bit or 16-bit boundaries.

Address DIP switches provide unlimited selection of short data I/O address mappings.

Built-in Tests

Output data can be read back in real-time or off-line mode.

Offline mode can be enabled by writing to the Control and Status Register (CSR) to set the test mode bit.

When test mode is enabled, all outputs are tri-stated (TRI-STATE).

Two test mode bits are provided so that each connector I/O (32-bit) can be tested independently if necessary.

Fault LED:

The Fault LED illuminates at power-up and system reset.

It can be extinguished under program control after successfully performing diagnostics.

Honeywell 05701-A-0511 5701 Series Control System

Key Features

The 5701 Series Control System is part of the 57 System family and is designed to monitor and control field installed industrial gas detectors.

The key features of the system are as follows.

Provides up to 16 gas detection channels in a standard 19” subrack using a 3U card format.

Provides up to 8 gas detection channels in a 3U card format in a half 19” subrack.

Racks are available for both front and rear wiring.

Simple field connection for wires up to 2.5mm2.

Single channel operation mode for high integrity systems.

Channel control cards are removable and do not interfere with other wiring.

Catalytic bridge or 4 – 20mA input.

Optional alarm switching relay output.

Multi-alarm modes for master, zone and voting alarms.

UP, DOWN, STEL and LTEL / RATE alarm outputs.

Update alarms for single or multi-channel alarms.

Remote inhibit and reset inputs.

Relay output on and/or off delay.

Selectable 0 – 20mA or 4 – 20mA isolated monitor outputs.

Easy calibration and operation with dedicated engineering card.

EMC compliant.

IBA ibaLink-SM-128V-i-2o VMEbus Interface Card

Introduction

The ibaLink-SM-128V-i-2o VMEbus Interface Card is a multi-purpose, bi-directional interface card designed for use in VMEbus-compatible PLCs and computer systems.

It can be used for both data acquisition and process monitoring as well as for control system applications such as the ibaLogic SoftPLC.

In the following, the board will be named SM128V to simplify the description.

Key features of the SM128V include :

 1 bi-directional fiber optic link with 64A+64D inputs/outputs per link (channel 1)

 1 unidirectional fiber optic link with 64A+64D outputs per link (channel 2)

 Synchronized transmission of all channels on both links at a rate of 1ms

 Address switch for cascading up to 8 SM128V interface cards on a link

Channel 1

 Compatible interface for ibaFOB-io, ibaFOB -4i (-S), ibaFOB-4o

 Compatible process i/o interface for ibaPADU-8-IO series and ibaNet750-BM series

 5 V power supply from VMEbus

The SM128V is available for VME32 and VME64 systems. The card requires a 5 V power supply.

Multilin 169PLUS-120N-125VDC Motor Management Relay

The 169PLUS-120N-125VDC is a highly configurable motor protection system manufactured by General Electric Multilin.

The relay comes with basic setpoints programmed for large motor systems, which can be further adjusted by the user upon receipt of the relay or as they become more familiar with the data generated by the relay.

While users can manage their motor systems with fairly minimal connection to GE Multilin’s 169PLUS-120N-125VDC.

However, the unit does offer a wide range of ports to diversify and customize the function of the relays.

Some of these connections include:

. Auxiliary Relay Contacts: these two contacts provide an additional NO/NC connection and operate independently of the other contacts.

The relays can be configured as non-fail-safe or fail-safe, and latching or non-latching.

They can be used for active alarm or trip functions and can trigger devices that are not just motors.

RTD Sensor Connections: The user can connect up to 6 resistance temperature detectors.

This is used to monitor values such as stator motor temperature, historical hottest temperature and ambient air temperature.

The relay then uses the data obtained from these connections to schedule the optimal cooling process.

. Analog output terminals: These two terminals can be configured using the relay’s setpoint system.

It can be connected to chart recorders, remote meters, programmable recorders and/or computer loads.

. Emergency Restart Terminal: This connection type overrides trips within the system and forces a restart of the motor.

These connections add to the overall versatility of the system and can further protect motor components from damage during operation.

Vibro-Meter VM600Mk2/VM600 ABE056 Slimline Racks OVERVIEW


SPECIFICATIONS

OVERVIEW

Housing: Painted galvanized steel sheet

Color: Off-white (RAL 9002)

Power supply: Integrated RPS1U power supply for VM600Mk2/VM600

The integrated RPS1U power supply provides +5 VDC and ±12 VDC for the VM600Mk2/VM600 and all installed modules (cards).

See also AC Input Power on page 3 and DC Input Power on page 3.

Power Input: The power input has an AC or DC connector (with RFI filter) and an on/off switch.

See Ordering Information on page 6 for information on the main power cord (power strip).

Backplane: Proprietary VM600Mk2/VM600 rack bus (open collector (OC) bus) for data/signal sharing between modules (cards)

Rack Slots (module (card) locations):

Front of rack:

– 1 × slot – module (card) position 01 – for handling modules (cards) such as MPC4Mk2. XMx16. MPC4. or AMC8.

Rear of rack:

– 1 × Slot – Module (Card) Position 01 – For associated input/output modules (cards) such as IOC4Mk2. XIO16T, IOC4T or IOC8T.

– 1 × slot – module (card) position 00 – for the relevant relay module (card), e.g. RLC16Mk2 or RLC16.

Vibro-Meter VM600Mk2/VM600 ABE056 Slimline Racks Applications


The rack has an integrated backplane that provides electrical interconnection between the integrated

power supply (RPS1U) and the installed VM600Mk2/VM600 modules (cards).

The rack also has a power check relay on the rear of the rack to indicate if the integrated power supply is functioning properly.

The VM600Mk2/VM600 Processing Module (Card) is mounted at the front of the rack and the

associated Input/Output Module (Card) is mounted at the rear of the rack.

The input/output modules (cards) provide connectors for connecting sensors/measurement

chains and for sharing various signals with external systems such as DCS or PLC.

In general, the VM600Mk2/VM600 ABE056 Ultra Slim Racks are factory-configured before shipment and are therefore ready for use.

Optionally, each module (card) can be reconfigured to meet the needs of a specific machinery monitoring application.

Each module (card) can be reconfigured to meet the needs of a specific machinery

monitoring application using the appropriate software package from Meggitt Vibro-Meter: VibroSight® or VM600 MPSx.

SPECIFICATIONS

OVERVIEW

Housing: Painted galvanized steel sheet

Color: Off-white (RAL 9002)

Power supply: Integrated RPS1U power supply for VM600Mk2/VM600

The integrated RPS1U power supply provides +5 VDC and ±12 VDC for the VM600Mk2/VM600 and all installed modules (cards).

See also AC Input Power on page 3 and DC Input Power on page 3.

Power Input: The power input has an AC or DC connector (with RFI filter) and an on/off switch.

See Ordering Information on page 6 for information on the main power cord (power strip).

Backplane: Proprietary VM600Mk2/VM600 rack bus (open collector (OC) bus) for data/signal sharing between modules (cards)

Vibro-Meter VM600Mk2/VM600 ABE056 Slimline Racks

VM600 ABE056 Ultra Slim Racks

(houses the MPC4 mechanical protection card)

Key Features and Benefits

– From the vibro-meter® product family

– 19-inch slim rack with 1U standard height

– Rugged metal construction

– Modular concept allows the addition of specific modules (cards) for machine protection or condition monitoring

– Rack or panel mounting

– Backplane supports open collector (OC) bus and power distribution for VM600Mk2/VM600 systems

– Integrated AC input or DC input power supply

– Power check relay

Applications

– VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

The VM600Mk2/VM600 ABE056 slimline rack is used to house the hardware for

the VM600Mk2/VM600 series of machine protection and/or condition monitoring systems in the Vibrometer® product line.

The VM600Mk2/VM600 ABE056 slimline rack has a standard height of 1U and provides mounting

space (rack slots) for a single wide VM600Mk2/VM600 processing module (card pair) and a relay module (card).

This rack is particularly suitable for industrial environments where the equipment must be permanently installed in a 19-inch cabinet or panel.

Different versions of the integrated RPS1U power supply can power the VM600Mk2/VM600

ABE056 slimline racks from an external AC or DC power supply.

Vibro-Meter VM600 AMC8 and IOC8T Analog Monitor Card Pairs Description

Description

AMC8 Card

The AMC8 is an analog monitoring card designed for use in the VM600 rack-mounted system

in the Meggitt Vibrometer® product family for machinery monitoring and protection applications.

This versatile card is capable of measuring and monitoring up to eight analog signal inputs simultaneously.

The AMC8 card is available in two versions: a “standard” version and a “circuit independent” version,

both of which are available as card pairs using the corresponding IOC8T input/output card.

The AMC8 card is mounted on the front of the VM600 rack (ABE04x or ABE056) and the IOC8T I/O card is mounted on the rear.

Both cards connect directly to the rack backplane via two connectors.

A pair of AMC8/IOC8T cards provides eight channels of temperature monitoring that accept resistance

temperature detector (RTD) and thermocouple (TC) temperature inputs as well as process inputs.

The source and type of each channel is selectable during card configuration.

Cold Junction Compensation (CJC) sensor processing is used for the thermocouple temperature

channel and can be used for two of the eight channels, also selectable during card configuration.

All inputs are conditioned and compared to user-configurable alarms that are defined through Meggitt’s VM600 MPSx software.

A pair of AMC8/IOC8T cards is configured (i.e. operated independently) via the RS-232 port on the front panel of the relevant AMC8 card.

The AMC8 card also provides access to the CPUx card (ABE04x only) in slot 0 of the VM600 rack via the VME bus.

These interfaces allow the operator to configure the VM600 card, access measurements,

view detailed board status, upload firmware updates, and more.

The AMC8 card can drive the four local relays on the IOC8T card, as well as any of the 16 relays

on the RLC16 card using the VM600 rack’s raw bus and/or open collector (OC) bus.

These cards also provide analog signal outputs based on current (0 to 25 mA). Voltage outputs are also supported.

Application Information

The AMC8/IOC8T card pair is ideally suited for machinery monitoring and protection in a variety of industrial applications.

Vibro-Meter VM600 AMC8 and IOC8T Analog Monitor Card Pairs

Key Features and Benefits

– From the Vibro-Meter® product family

– Card Pair Provides 8 Channels of Temperature and Process Monitoring for VM600 Systems 

Provides 8 Channels of Temperature and Process Monitoring for VM600 Systems

– 8-channel software configuration capability:

Thermocouple (TC), Resistance Temperature Detector (RTD), Current and Voltage Inputs

– Analog signal inputs from 0 to 25 mA and 0 to 10 V Range of analog signal inputs

– Cold Junction Compensation (CJC) sensor processing on two optional channels

– Current output (optional voltage output)

– Programmable alarm, hazard, and OK setpoints

– Includes 4 relays that can be used for alarm signaling under software control

– Control outputs to RLC16 relay card on VM600 frame

– Front panel LEDs indicate status and alarms

– Real-time plug-in card (hot-swappable)

– Available in ‘standard’ and ‘circuit independent’ versions

Applications

– Mechanical protection and/or condition monitoring

Vibro-Meter VM600 IOC4T Input/Output Card Application

Application Information

The IOC4T, when paired with the MPC4 Machinery Protection Card, is ideally suited for

machinery monitoring and protection in a variety of industrial applications.

For more information on using the MPC4/IOC4T card pair, see

VM600 Machinery Protection System (MPS) Hardware Manual and the VM600 MPSx Software Manual.

For information on using the MPC4/IOC4T card pair in a functional safety environment, refer to the VM600 Functional Safety manual.

Parameters

Dynamic Signal Input

Filtering: Filtering to prevent electromagnetic interference (EC compliant).

Refer to the VM600 MPC4 Mechanical Protection Card datasheet for more information.

Buffered dynamic signal output

Filter: Filtered to prevent electromagnetic interference (EC compliant).

Refer to the VM600 MPC4 Machine Protection Card datasheet for more information.

Speed/phase reference input

Filter: Filtered to prevent electromagnetic interference (EC compliant).

Refer to the VM600 MPC4 Machine Protection Card datasheet for more information.

Discrete Signal Interface (DSI) inputs

Search for products

Back to Top
Product has been added to your cart