Honeywell FC-SAI-1620M Benefits Built on QMR technology

Built on QMR technology:

Safety Manager™ is based on reliable Quadruple Modular Redundancy (QMR™) diagnostic technology and 2oo4D architecture.

QMR increases system flexibility, enhances diagnostic messaging, and increases system fault tolerance for critical applications.

This technology enables Safety Manager to handle multiple system failures to meet the needs of critical control applications.

In addition, Safety Manager is the cornerstone for integrating SIL (Safety Integrity Level) rated sensors and valve actuators in the field.

This ensures effective deployment of safety instrumented functionality for complex and hazardous processes.

Whether it’s integrating SIL1-2 safety transmitters (ST3000 and STT250) or safety valve positioners

to enhance safety and field asset management, Safety Manager is the perfect enabler for Safety Instrumented Systems (SIS).

Benefits:

Simplified engineering and design efficiencies – Simplified safety network design

Enhanced system reliability and robustness – utilizes Design for Six Sigma (DFSS) and IEC 61508 standards

Improved process availability – uninterrupted operation during system degradation with QMR technology

Improve O&M performance – unify critical process data and control information for seamless access

Protect investment – facilitate migration from FSC to QMR safety technology

Comply with safety standards – equip industries with SIL3 safety-compliant tools, hardware and software throughout the life cycle of the installation

The IO modules utilize European standard sized instrumentation cards.

The module front panels are 3 HE (3U) high and 4 TE (4 HP) wide. Each IO chassis holds 18 IO modules.

All IO modules have standard 32-pin DIN 41612F connectors.

All IO chassis are equipped with an IO backplane with mating 32-pin connectors and key coding to prevent incorrect insertion of IO modules.

Safety Manager offers a wide range of digital and analog inputs and outputs with different characteristics to meet the needs of a variety of field devices.

Table 12 on the next page lists the available inputs and outputs for the Safety Manager.

Honeywell FC-SAI-1620M Safety Manager

Enhanced business results:

Safety Manager™ is an evolution of the proven Fail Safe Controller (FSC®) safety system

platform that has been globally recognized for more than 15 years.

It embodies proven technology backed by Honeywell’s two decades of 

expertise in process safety management. This includes the integration

of process safety data, applications, system diagnostics and critical control strategies.

Safety Manager is designed to enhance business performance, improve process safety and protect plant

assets and people.

The safety system is seamlessly integrated with the Experion™ Process Knowledge System

(PKS) into a single architecture, providing an excellent opportunity to improve safety and process

availability.

Experion PKS ensures unparalleled connectivity between processes and business operations,

optimizes workflows, simplifies maintenance tasks, enhances safety management, and frees personnel

from manual tasks.

Honeywell FC-SAI-1620M Safety High Density Analog Input Module

Introducing:

Honeywell Safety Manager™ is a reliable and highly complete safety system tailored for critical control

applications.

It is an integral part of Honeywell Experion™ PKS and integrates seamlessly

into PlantScape and can also operate autonomously.

Safety Manager is the foundation of functional safety, ensuring the well-being of individuals,

plant assets and the environment while optimizing plant continuity.

Safety Manager is a user-programmable, modular, microprocessor-based safety system

capable of performing a wide range of high integrity process control and safety instrumentation functions, including:

High integrity process control

Burner/boiler management systems

Process protection and emergency shutdown

Turbine and compressor safety protection

Fire and gas detection systems

Pipeline monitoring

VMIVME-2510B 64-bit TTL Digital Input/Output

Features:

. Direction of each 8-bit port is individually programmable

.64 mA sink current capability (15 mA source) .

. Separate board address decoding for control and data registers .

. Built-in test logic for fault detection and isolation .

. Highly reliable DIN-type I/O connectors .

. 8-bit, 16-bit, 32-bit transfers

The VMIVME-2510B is a member of the VMIC Megamodule family, which is designed for universal

programming.

The subsystem can be configured with consecutive I/O addresses to conserve memory.

These products (VMIVME-1110. VMIVME-2120. VMIVME-2130. and VMIVME-2510B) are designed with

two sets of board address switches to provide efficient memory address mapping for CSR and I/O addresses.

The CSR address switches can be configured so that all CSRs on the various boards in the system can be mapped to contiguous memory locations.

Megamodule products are also designed to support 8-bit, 16-bit and 32-bit data transfers.

Specific hardware has been designed into the VMIVME-2510B to support the built-in test functions.

The VMIVME-2510B supports off-line and on-line fault detection and isolation. The front panel Fail LED is used to indicate when a fault exists on this board.

The LED is illuminated at power-up or reset. The LED can be turned off after successfully completing board level diagnostics.

Honeywell 05701-A-0511 5701 Series Control System Architecture

Architecture

The system consists of a single 1” (2.54 cm) wide board mounted in a ruggedized rack designed for European style cabinets.

Two rack widths are available:

a. 19-inch with 17 card slots for up to 16 channel control cards and one engineering card.

b. Half 19 inches with 9 card slots for up to 8 channel control cards and 1 engineering card.

Each subrack contains one engineering card and one DC input card to form the rack system.

The system is designed to accommodate different customer wiring configurations, and for this reason,

the control functions are separated from the relays and field wiring connections.

Therefore, single channel gas detection consists of :

a. Sensor Driver Module

For compatibility with a wide range of input and sensor types, the circuitry required to control the sensors is mounted on separate plug-in sensor driver modules.

These modules plug directly into the channel control card and are factory installed. Two different modules are available, one for catalytic inputs and the other for 4 – 20mA inputs.

b. Single Channel Control Cards

Each single-channel control card is self-contained and contains all the necessary electronic circuitry to provide sensor actuation, 

alarm detection, and gas level indication for that gas detection channel.

c. Field Interface or Relay Card

Field interface/relay cards provide interface connections between the control card and the respective field-connected gas sensors.

In addition, relay cards provide alarm outputs for field connections.

IBA ibaLink-SM-128V-i-2o Relevant specifications (VITA standards)

Relevant specifications (VITA standards):

 VMEbus

 IEEE 1014-1987

 VME64

 ANSI VITA 1-1994 VME64X; VITA 1.1-19

Remarks Since an analog channel always corresponds to a digital channel in the iba bus concept, 

an analog value and a digital value are referred to as a channel or a signal for simplicity of description.

Scope of delivery

The goods are checked for completeness and integrity after unpacking.

The scope of delivery includes

 Device ibaLink-SM-128V-i-2o

 Manual

Safety instructions

Specified use

The device is an electrical device. It can only be used for the following applications:

 Automation of industrial systems

 Measurement data logging and analysis

 Application of ibaSoftware products (ibaPDA, ibaLogic, etc.)

The device may only be used for the applications shown in chapter 11. Technical data.

IBA ibaLink-SM-128V-i-2o Device description

Device description

The following non-privileged modes of VME access are possible:

 A24 and A32 in the following VMEbus data formats

 D08 (E0)

 D16

 D32

 A40 MD32 (on special request)

The BLT and MBLT modes as well as the auto-configuration and geo-addressing functions are being

prepared, but are not available at this time.

The 2eVME mode has not yet been implemented. Access is only allowed in unprivileged data access

mode.

The SM128V is a passive board on the VMEbus, i.e., it will not be actively accessed or interacted with on

the VMEbus.

The board uses 256 kbytes of address space on the VMEbus.

Euresys Compliant with Genicam CXP-12 3D-LLE Coaxlink Quad

The Coaxlink driver includes the following tools:

Genicam Browser: An application giving access to the GenICam features exposed by the GenTL

Producer(s) in the system.

GenTL Console: A command-line tool giving access to the functions and commands exposed by the

Euresys GenTL Producer.

Compliant with Genicam

Including support for

GenApi

The Standard Feature Naming Convention (SFNC)

GenTL

Windows and Linux drivers available

Including support for the AArch64 64-bit ARM architecture for Linux

Developed with the support of the DG06 Technology Development Department


Area-scan triggering capabilities

A trigger is used to start the acquisition when the part is in position. Hardware triggers come from the

Coaxlink’s I/O lines.

Software triggers come from the application.

An optional trigger delay is available to postpone the acquisition for a programmable time.

A trigger decimation function allows to skip some of the triggers.

Camera exposure control allows the application to control the exposure time of the camera.

When the acquisition starts, at the appropriate timing, the Coaxlink board generates a signal to control an

illumination device

connected to one of its output lines.

Euresys General purpose I/O lines CXP-12 3D-LLE

General purpose I/O lines

Compatible with a wide range of sensors and motion encoders.

High-speed differential inputs: Quadrature motion encoder support up to 5 MHz.

Isolated current-sense inputs: 5V, 12V, 24V signaling voltages accepted, up to 50 kHz, individual galvanic

isolation up to 500VAC RMS.

Isolated contact outputs.

High-speed 5V-compliant TTL inputs/ LVTTL outputs.

High-performance DMA (Direct Memory Access)

Direct transfer into user-allocated memory

Hardware scatter-gather support

64-bit addressing capability

Area-scan triggering capabilities

A trigger is used to start the acquisition when the part is in position. Hardware triggers come from the

Coaxlink’s I/O lines.

Software triggers come from the application.

An optional trigger delay is available to postpone the acquisition for a programmable time.

A trigger decimation function allows to skip some of the triggers.

Camera exposure control allows the application to control the exposure time of the camera.

When the acquisition starts, at the appropriate timing, the Coaxlink board generates a signal to control an

illumination device connected to one of its output lines.

Euresys Coaxlink Quad CXP-12 3D-LLE Long cable support

Long cable support

40 meters at CXP-6 speed (6.25 Gbps)

100 meters at CXP-3 speed (3 Gbps)

Use standard coaxial cables

A single inexpensive cable for data transfer, camera control, trigger and power supply

Top reliability and flexibility, performs in the harshest environments

Robust connectors

Coaxlink uses DIN 1.0/2.3 connectors with push/pull latching system for reliable connections

Memento Event Logging Tool

Memento is an advanced development and debugging tool available for Coaxlink cards.

Memento records an accurate log of all the events related to the camera, the frame grabber and its driver

as well as the application.

It provides the developer with a precise timeline of time-stamped events, along with context information.

It provides valuable assistance during application development and debugging, as well as during machine

operation.

Search for products

Back to Top
Product has been added to your cart