Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Prosoft A-FFL/B FOUNDATION™ Fieldbus H1 Master for EtherNet/IP™ and Modbus® TCP

The FF Link module simplifies the implementation of FOUNDATION™

Fieldbus H1 by combining an EtherNet/IP™ and Modbus® TCP Linking

device with an internal isolated power conditioner and bus terminator.

The FF Link supports module redundancy when in EtherNet/IP target

mode, allowing two FF Link masters to be connected to the same H1

segment in a one-active-one-standby strategy.

Configuration is achieved using Aparian’s free-downloadable Slate

configuration environment. Slate generates H1 device specific UDTs and

mapping code which can be imported into Studio 5000. allowing even

complex systems to be configured in minutes.

Prosoft ELX3 Features

Features

• Redundant Power connections (12 ~ 24 V DC)

• Multiple Ethernet ports (4) supporting 10/100/1000 Mbit/s

• Industrial-rated hardware supporting user defined custom Docker container

applications

• ProSoft supported ELX-EIP-MBTCP protocol gateway container for EtherNet/IP

and Modbus TCP/IP protocol gateway conversion

• Class 1 Division 2 hardware with -40°C to +70 °C operating temperature range

for Edge applications

Prosoft ELX3 Industrial Edge Gateway

The ELX3 ProLinx Edge™ Gateway is designed to combine OT Protocol

Conversion with edge computing capabilities to meet your most demanding

Industrial Internet of Things (IIoT) applications.

For industrial protocol conversion, the ELX3 supports the ProSoft ELX-EIP

MBTCP protocol gateway container, giving you the ability to do protocol

gateway conversion for EtherNet/IP to Modbus TCP/IP.  Built on the field

proven ProSoft communication gateway solutions and as an EtherNet/IP

ODVA conformance tested solution, this protocol gateway container solves

many OT protocol conversion needs.

The ELX3 additionally provides the ability to run Docker containers providing

the flexibility to run custom code for advanced applications such as machine

learning, predictive maintenance, or custom protocol drivers.

With hardware supporting an extended operating temperature range of -40C

to +70C as well as Class 1 Div 2 ratings, this Edge gateway is designed to

withstand harsh industrial environments.

The new ProLinx Edge™ ELX3 module provides OT protocol conversion and

the ability to concurrently run custom Docker container applications all in a

single hardware platform designed to withstand harsh conditions.

Prosoft A-CFR ControlNet Fiber Repeater

The A-CFR ControlNet Fiber Repeater extends the length of a network for

a point-to-point topology while performing network media conversion from

copper to fiber, and from fiber to copper.

The A-CFR can be used when a medium-distance fiber link between two

ControlNet products is needed. The fiber link provides isolation between

nodes and is less susceptible to a noisy environment than copper media.

Features

• A pair of A-CFR modules can be used to physically extend a ControlNet

network by up to 3 km (1.86 miles) using

standard industrial multi-mode fiber.

• Supports Redundant ControlNet applications by duplicating the setup.

• Supports common industrial fiber cables:

• OM1 – 62.5/125 μm

• OM2 – 50/125 μm

• Wide operating voltage 10 to 32 VDC

• Small form factor – DIN rail mounted

Prosoft A-CANBR/B Features

Features

• Receive up to 100 pre-configured CAN Bus packets.

• Send up to 100 pre-configured CAN Bus packets.

• CAN Bus transmission can be scheduled (periodic), or externally triggered,

sent on Start-up, or any combination.

• Logix L5X generation – Ready for import

• Supports Passthrough Messaging from Logix

• Module has various Primary Interfaces:

o EtherNet/IP Target (Class 1 connection)

o Modbus Server (TCP, RTU232. and RTU485)

o Modbus Client (TCP, RTU232. and RTU485)

o EtherNet/IP Originator (Class 1 connection with up to 10 EtherNet/IP devices

and Explicit Messaging, including

• Direct-To-Tag Logix tag access, with up to 10 EtherNet/IP devices).

• Slate software provides a CAN Bus and Modbus packet capture utility for better

diagnosis of communication issues.

• Supports common CAN Bus Baud Rates (10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M)

• Dual Ethernet ports which support Device-Level-Ring (DLR).

• Network Time Protocol (NTP) supported for external time synchronization.

• Small form factor – DIN rail mounted

• The Slate Configuration Utility software is used for configuration and troubleshooting

of the router. The stand-alone

configuration utility allows users to define the setup and configuration of the router

and its connections with controllers and devices.

Prosoft A-CANBR/B CAN Bus Router/B

The A-CANBR/B CAN Bus Router provides intelligent data routing between

either EtherNet/IP™ or Modbus® TCP/RTU and a CAN Bus network. This

allows the user to integrate CAN Bus devices into a Rockwell Automation

Logix platform (e.g., ControlLogix® or CompactLogix™) or any Modbus

Client or Server device with minimal effort.

The A-CANBR/B also provides a range of statistics, CAN Bus and Modbus

packet capture functions, and internal Modbus and Data table reads to

simplify remote diagnosis. A built-in webserver provides detailed

diagnostics of system configuration and operation, including the display of

CAN Bus operation and communication statistics, without the need for any

additional software.

Prosoft EtherNet/IP™ Filtering Features

Filtering Features

The filtering is extremely flexible. For example, you can select frames:

 To and from a single drop

 With errors

 By type (I/O updates, directed messages, etc.)

 With specific data values

You create an equation that defines the criteria used to select frames of interest.

The equation consists of data values and operators.

Capture Features

The AN-X-AMX gateway can control how captured network frames appear, including:

 Format of timestamps

 Format of data – hexadecimal, unsigned or signed integer, binary

 Timing information – values and text graphs of time between frames and time

 From the start of one selected frame and the start of the next

 Display of frame CRCs

 Detailed status information for frames

Web Access

AN-X acts as a web server. Any web browser can connect to the AN-X to view diagnostics and current I/O data.

A web browser can be used to configure the drop number and drop depth, and to configure scheduled an

AN-X to AN-X data exchange.

Prosoft EtherNet/IP™ to Reliance AutoMax DCS

The AN-X-AMX Gateway lets you capture, store and analyze network data

on a Reliance AutoMax DCS or remote I/O network. The AN-X-AMX

gateway can be used to examine the behavior of all drops, verify network

data and timing, locate network errors and troubleshoot problems with the

network and with the process.

The AN-X-AMX gateway does not occupy a drop on the network or affect

existing network traffic in any way. The AN-X-AMX gateway captures and

stores ALL network frames, with timestamps to microsecond precision and

uses post-capture filtering to select frames of interest for further analysis.

This approach ensures that everything leading up to an event of interest is

preserved.

The alternative approach, pre-filtering and saving only certain messages,

might cause you to lose key information. At the end of each minute, a new

file is created and the file older than the keep time is deleted.

Typical capture file size is 2.5 megabytes/minute, 150 megabytes/hour,

3.6 gigabytes/day. The AN-X-AMX gateway is field upgradeable.

The operating system and firmware can be upgraded over Ethernet.

Prosoft PLX31-EIP-MBS EtherNet/IP™ to Modbus® Serial Communication Gateway

ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication gateway

allows high-speed bi-directional data transfers between EtherNet/IP™ PACs or

devices and Modbus®-enabled PACs or devices.

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and

CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial

devices are widely used in nearly every industry and include SCADA systems and

Power Monitors.

The gateway includes several features that allow for simplified integration, reduced

commissioning time and optimized performance.

Features

 Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or

control data, optimizing Ethernet bandwidth.

 Includes an embedded EDS Add-On Profile, allowing for simplified integration and

reduced commissioning time.

 Includes a SD card slot (SD card optional) for storing configuration files.

This can be used for disaster recovery.

 ProSoft Discovery Service: This utility allows your PC to see the gateway and change

its default IP address without being on the same subnet.

 Secure module configuration via module switch (v1.04 and greater).

 Up to 10.000 16-bit registers can be used to exchange large amounts of data.

Prosoft PLX31-EIP-MBS4 Features

ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication

gateway allows high-speed bi-directional data transfers between EtherNet/IP™

PACs or devices and Modbus®-enabled PACs or devices.

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and

CompactLogix™, as well as several Schneider Electric® controllers.

Modbus® Serial devices are widely used in nearly every industry and include

SCADA systems and Power Monitors. Four ports allow for connectivity of up

to 400 Modbus® Serial devices, reducing the amount of gateways required

for your application.

In addition, the gateway includes several features that allow for simplified

integration, reduced commissioning time and optimized performance.

Features

 Data prioritization: Multiple I/O connections allow you to set RPIs for status

and/or control data, optimizing Ethernet bandwidth.

 Includes an embedded EDS Add-On Profile, allowing for simplified integration

and reduced commissioning time.

 Includes a SD card slot (SD card optional) for storing configuration files.

This can be used for disaster recovery.

 Four serial ports allow for connectivity of up to 400 Modbus® devices, reducing

the amount of gateways required for your application.

 ProSoft Discovery Service: This utility allows your PC to see the gateway and

change its default IP address without being on the

same subnet.

 Secure module configuration via module switch (v1.04 and greater).

 Up to 10.000 16-bit registers can be used to exchange large amounts of data.