Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Prosoft PLX32-MBTCP-SIE Modbus® TCP/IP to Siemens® Industrial Ethernet Communication Gateway

ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet

gateway allows high speed bi-directional data transfers between

Schneider Electric® PACs and Siemens S7 and S5 PACs.

Two ports allow each protocol to reside on separate subnets, allowing

you to pass data between the two subnets without changing each

device’s IP address.

Features

 Two separate Ethernet ports allow each protocol to reside on separate

subnets. This allows you to pass data between the two

subnets without changing each device’s IP address to be on the same subnet.

 In addition to S7 controllers, the gateway can also be used with Siemens

S5 controllers with an appropriate interface.

 Gateway includes a SD card slot (SD card optional) for storing configuration

files. This can be used for disaster recovery.

 Secure module configuration via module switch (v1.04 and greater).

 Up to 10.000 16-bit registers can be used to exchange large amounts of data.

Prosoft PLX31-EIP-PND EtherNet/IP™ to PROFINET® IO Device Gateway

The EtherNet/IP™ to PROFINET® IO Device (slave) gateway offers bi-directional 

data transfers between EtherNet/IP™ controllers and a PROFINET® IO controller.

The EtherNet/IP™ Driver supports I/O connections for guaranteed data delivery or

Message instructions to send data to/from the PACs. The gateway supports 1440

bytes of input data and 1440 bytes of output data for larger applications.

In addition, the gateway’s multiple I/O connections, allow you to set different RPIs

for control data and module diagnostics, enabling you to optimize your Ethernet

bandwidth.

Features

 Embedded EDS Add-On Profile allows for simplified integration and reduced

configuration time for Rockwell Automation PACs.

 No ladder programming is required when using I/O connections.

 Multiple I/O connections allow you to set different RPIs for status and control

data, enabling Ethernet bandwidth optimization.

 Communication via an I/O connection provides guaranteed data delivery and

enables a PAC to monitor for communication faults.

 SD card slot (SD card optional) is used for storing configuration files in the

event of a disaster.

 ProSoft Discovery Service allows your PC to find the gateway and edit its default

IP address without being on the same subnet.

 Video setup tutorial provided at psft.com/Ap5

 Secure module configuration via module switch (v1.04 and greater).

Prosoft MVI56-104S IEC 60870-5-104 Ethernet Server Communication Module

The IEC 60870-5-104 Server functionality supported by the module includes: 

 The IEC 60870-5-104 communication driver is built in accordance to the approved 

IEC specification 

 The module functions as a Server on the network supporting data read/write 

commands from an IEC 60870-5-104 client on the network 

 One TCP server socket 

 Supports unsolicited messages, either cyclic or spontaneous (cyclic rate is 

configurable) 

 Supports clock synchronization commands from client or from the ControlLogix 

processor 

 Supports Group interrogation (Global, General 1 to 16, Global Counters, Counters 

1 to 4) 

 Event timestamping configurable by type (None, 24 bit, 56 bit) 

 Event queue supports 99 points for each data type 

 Optional user defined list of acceptable client host IP addresses 

 Configurable Common ASDU address (sector) and Information Object Address 

 An IEC Interoperability Document for the MVI56 is available which fully documents 

data types supported by the module

Prosoft MVI56-104S General specifications

General specifications include:

 User-definable database memory usage, based on data types and point counts

 Protocol implementation conforms to the IEC 60870-5-104 specification with fully-configurable

parameters

 SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions (events)

IEC 60870-5-104 Server Specifications 

Operating in the Server mode, the module accepts commands from a Client(s) to 

read/write data stored in the module’s internal registers. This data is easily and 

continuously transferred between the MVI56-104S, Edition 2 module and the 

ControlLogix processor’s data registers. 

Prosoft MVI56-104S General Specifications – 104S

General Specifications – 104S

Operating in server mode (only), the 104S protocol implementation accepts commands

from an IEC-60870-5-104 Client to read data stored in or write data into the gateway’s

internal database memory registers. The 104S implementation is also capable of generating

unsolicited messages. Unsolicited messages can be either spontaneous (event-driven) or

cyclic (timing-driven) communication.

The remote Client device uses the fully-configurable gateway memory database to control

outputs and monitor inputs to devices on the

IEC 104 network.  Changes to the gateway database can also be used to transfer monitoring

and control data to devices connected to

the gateway using another installed network protocol. The 104S gateway thus provides a data

transfer solution between an IEC 60870

5-104 Ethernet network and other serial and Ethernet network protocols, as well as proprietary interfaces.

Prosoft MVI56-104S IEC 60870-5-104 Ethernet Server Communication Module with Edition 2 Support

The MVI56 IEC 60870-5-104 Server Communication Module allows

ControlLogix compatible processors to interface easily with IEC 60870-5

104 protocol-compatible hosts.

The MVI56-104S module acts as an input/output module between the IEC

60870-5-104 Ethernet network and the ControlLogix processor. Data

transfer between the module and the processor is asynchronous from the

actions on the network. Databases are defined by the user for the module to

hold data as required by the protocol.

General Specifications

 Single Slot – 1756 backplane-compatible

 The module is recognized as an Input/Output module and has access to

processor memory for data transfer between processor and module.

 Ladder Logic is used for data transfer between module and processor.

Sample ladder file included.

 Configuration data obtained from configuration text file downloaded to module. 

Sample configuration file included

 Local or remote rack

Prosoft MVI56-EGD Features and Benefits

Features and Benefits

GE Fanuc Automation and GE Drive Systems developed an Ethernet

Global Data, or EGD, exchange for PLC and computer data in 1998.

Ethernet Global Data (EGD) offers versatility where a mix of control

devices requires cooperation with each other. This involves sharing

of information across the applications regardless of device or network

type, often at high speed, and with high reliability. High reliability

means fewer communication failures and having the ability to detect

failures upon occurrence. Particular emphasis is delivered for

applications requiring periodic or frequent updates and time

synchronization of devices. The protocol supports Unicast, Broadcast

and Multicast group messaging. Efficiency is based on the fact each

device on the network can produce these types of messages and

each device determines which of these messages to consume.

Prosoft MVI56-EGD GE Ethernet Global Data Communication Module

MVI56-EGD

The Ethernet Global Data (EGD) module can be used to interface

many different protocols with EGD devices. The EGD driver supports

both the producer/consumer service port (18246) and the command

service port (7937) using the UDP protocol over an IP network. The

user defines the data to be produced and consumed in a

configuration file downloaded to the module.

General Specifications

• Single Slot – 1756 backplane compatible

• The module is recognized as an Input/Output module and has

access to processor memory for data transfer between

processor and module

• Ladder Logic is used for data transfer between module and

processor. Sample ladder file included.

• Configuration data obtained from configuration text file

downloaded to module. Sample configuration file included

• Local or remote rack

Prosoft MVI56-LTQ Functional Specifications

Functional Specifications

 Support for the storage and transfer of up to 150 valves to the ControlLogix

processor’s controller tags

 Emulates Limitorque’s Port A/B polling scheme using both ports on the module

 Supports the following valves

o MX/DDC Modbus

o UEC-3-DDC Modbus

o DDC-100M I/O module

o DDC-100M field unit

o Valvcon IVO (unit in multi-drop mode only)

 Software configuration

o Baud rate: 1200 to 115200

o Message response timeout

o Number of active slaves

o Last state on communication failure for valve data

o Network polling scheme

o Active slave table (bit mapped)

o Use of CTS module line option

 Support command

o Continuously polled

o Read registers 40008 to 40013. optional 40055 or 40006/40007

o Commands: open, stop, close, initiate network ESD, terminate network ESD,

engage contactors 1 to 6. disengage contactors 1 to 6. position valve (0 to 100%)

 Data returned to the processor for each valve

o Valve position

o Status register

o Fault register

o Digital outputs

o Digital inputs registers 1 and 2

o Communication error code

o Communication poll counter

o Special polled registers

Prosoft MVI56-LTQ Limitorque Valve Actuator Master Communication Module

The MVI56 Limitorque Valve Actuator Master Communication Module allows

ControlLogix compatible processors to interface easily with Limitorque Valve

Actuators and other Limitorque protocol compatible devices.

The MVI56-LTQ module acts as an input/output module between the Limitorque

valve network and the ControlLogix processor. The data transfer from the

ControlLogix processor is asynchronous from the actions on the network. The

1500-word register space in the module transfers the valve information from the

module to the processor. Ladder logic is responsible for control of the valves.

Data transferred from the processor to the module instructs the module to

execute commands to valves on the Limitorque network.

Search for products

Back to Top
Product has been added to your cart