ABB The equipment used for this analysis consists of the standard NGC8209

Equipment

The equipment used for this analysis consists of the standard

NGC8209 mounted in a black case. It is recommended that

the unit be left in an operational mode while transporting.

All the valves, gauges, inlet ports, and PCCU32 (the laptop

driven man-machine interface) connectors are bulkhead

mounted on panel to provide the technician with ready access.

Stream averages for the (default¹) 840 last hours, 35 last

days and the most recent last month analyses. Operational

Parameters for the (default¹) last 480 cycles (Diagnostics Report):

– Selected peak times

– Selected peak areas

– Ideal Btu/CV

– Carrier regulator pressure

– Oven temperature

– Ambient temperature

– Sample pressure

– Detector noise values

– Detector balance values

Audit logs (Default¹)

– Last 480 alarms

– Last 480 events

ABB NGC8209 Natural gas chromatograph Historical data

Historical data

The NGC8209 is designed to retain historical data. This data

can be used for custody transfer needs, verify transmitter

operation over time, and provide a limited data backup for

communication link reliability. In addition, various CSV file

outputs are available to download the analysis data into

spreadsheet based company specific data sheets, and

outputs to 3rd party gas accounting packages.

The default¹ memory configuration provides the most recent

480 analysis cycles containing:

– Normalized components

– Un-normalized components

– Ideal Btu/CV

– Real Btu (wet and dry) / CV (superior and inferior)

– Relative density (specific gravity)

– Density

– GPM

– Wobbe index

– Alarms

Stream averages for the (default¹) 840 last hours, 35 last

days and the most recent last month analyses. Operational

Parameters for the (default¹) last 480 cycles (Diagnostics Report):

– Selected peak times

– Selected peak areas

– Ideal Btu/CV

– Carrier regulator pressure

– Oven temperature

– Ambient temperature

– Sample pressure

– Detector noise values

– Detector balance values

Audit logs (Default¹)

– Last 480 alarms

– Last 480 events

Data retained by the NGC8209 can be collected via a remote

communication link or by the laptop PC local operator interface PCCU 32.

ABB The equipment used for this analysis consists of the standard NGC8206

Equipment

The equipment used for this analysis consists of the standard

NGC8206 mounted in a powder-coated box. The equipment

used for this analysis consists of the standard NGC8209

mounted in a black case. It is recommended that the unit be

left in an operational mode while transporting.

All the valves, gauges, inlet ports, and PCCU32 (the laptop

driven man-machine interface) connectors are bulkhead

mounted on panel to provide the technician with ready access.

Available options

• Sample and GC Rotometers

• 120/240 V AC / 24 V DC to 12 V DC power supply

• Modular Sample System for Non-pipeline quality natural gas

and Sample transport lag-time needs: Type 4 w/ liquid shut off

• Temperature Compensation Probes:

• Fixed

• Retractable

• Regulators, carrier and calibration blend

• Start up/calibration/validation gas sample (+2% Cal Blend)

• Export crating

• Tool kit

• Various maintenance kits

• On board digital ¼ VGA display with multiple screen access

• USB (Host and Client) and Ethernet ports

• SD memory cards

• Feed-Through heater

• Heat trace internal and external tubing

ABB Portable NGC Natural gas chromatograph Standard features

Standard features

Modular design includes

• Portable GC interface allows user analysis customization

• Modular software – application based plug in software

modules

• Manifold module (internal tubing now replaced by manifold)

• Analysis sections contain stream selection solenoids,

temperature and pressure regulation, 32 bit digital detector

electronics, replaceable column / valve modules and a low

power 32 bit digital controller, using Windows CE® (internal

to GC unit)

• Microsoft® Windows® based man-machine interface

software (PCCU)

• USB MMI port connectivity

• Ethernet connectivity

• Lithium battery-backed RAM

• Two remote serial digital communications ports; one local port

• Comprehensive diagnostics and wizards available to users

• Audit-quality historical data; date and time stamped

• Operational fault/warn alarms available

• Detectors – constant temperature, glass encapsulated

thermister beads for rugged service and long life; will not

burn out on loss of carrier

• 10 port valves have no moving metal parts in each analysis unit

• Low utility usage – low-power, low-carrier, no instrument air required

• On demand or scheduled automatic calibration and diagnostics

ABB The NGC8206 measures a C6+ (back flushed) peak

Description

The Portable NGC analyzes each sample utilizing established

chromatographic techniques. The resulting information

consists of mole percent values for the following:

• Air (N2 thru CO)

• C1

• CO2

• C2

• C3

• IC4

• NC4

• NeoC5

• IC5

• NC5

• C6+

• H₂S optional

The NGC8206 measures a C6+ (back flushed) peak. Users may

input the results of a comprehensive lab analysis that reflects

the split or ratio of C6 through C10 components. This ratio

can be used in subsequent analyses and energy calculations.

The NGC8209 measures a C9+ (back flushed) peak. Users may

input the results of a comprehensive lab analysis that reflects

the split or ratio of C9 through C12 components. This ratio

can be used in subsequent analyses and energy calculations.

Calculated values include

• Relative density (specific gravity)

• Btu/CV (heating) value

• GPM (gallons of liquid

ABB The truck is moved as close to the sample point as is practical

The truck is moved as close to the sample point as is

practical. A flexible sample line is then uncoiled and attached

to the probe in the flowing natural gas pipeline. If the dew

point of the gas or the weather demands it, this flexible

tubing must be heated. A sample of the gas is extracted from

the probe in the line, purged through the flexible line and then

transported to the analyzer. There it is processed for particle

removal and phase integrity, injected onto the

chromatographic columns where component separation

occurs. These components are then quantified by peak

integration and concentration is calculated. The other data of

interest is then calculated from these concentrations.

The averaged output can be formatted to be accepted by a

3rd party gas accounting software system, allowing

automatic downloads of the analysis data. Analysis done on

site is valuable because:

• Transportation of DOT regulated gas cylinders is avoided

• Time and cost of subsequent laboratory analysis

• Problems with sample handling

• Economic solution for gas quality measurement when the

gas volumes are too low to justify on-line chromatography

ABB Portable NGC Natural gas chromatograph

Introduction

This data can be used for flow computers, RTU’s, gas

accounting systems, and SCADA systems for the energy,

AGA3. 7. 8. and 10 calculations at the meter site. This data

output can be a CSV file format so that analysis data systems

can easily incorporate the information. The number of runs

and the number of averages can be selected.

The averaged output can be formatted to be accepted by a

3rd party gas accounting software system, allowing

automatic downloads of the analysis data. Analysis done on

site is valuable because:

• Transportation of DOT regulated gas cylinders is avoided

• Time and cost of subsequent laboratory analysis

• Problems with sample handling

• Economic solution for gas quality measurement when the

gas volumes are too low to justify on-line chromatography

ABB The RET670 can be used with the IEC 61850-9-2LE

The RET670 also features pole slip protection, which detects and evaluates pole slips occurring in the

power system and takes the necessary action.

Sections of the power system that are swinging away from each other can be separated by

the line closest to the center of the power swing, allowing the two systems to remain stable when

separated.

The RET670 can be used with the IEC 61850-9-2LE process bus with up to six Merge Units (MUs).

Advanced logic functions allow user logic to be programmed with graphical tools to enable special

applications such as automatic opening of disconnect switches in multi-breaker arrangements, closing of

breaker loops and load transfer logic.

Logic can be monitored and debugged online in real time for testing and commissioning.

Communication via fiber optic connections ensures immunity to interference.

Six software packages are defined for the following applications:

– Transformer backup protection (A10)

– Voltage control (A25)

– Single-breaker, two-winding transformers (A30)

– Double-winding transformers with multiple circuit-breaker arrangement (B30)

– Three-winding transformers in single-breaker arrangement (A40)

– Triple-winding transformer in multi-breaker arrangement (B40)

The optional functions are not configured, but a maximum configuration with all optional

functions is available as a template in the graphical configuration tool.

Templates for alternative configurations for auto-transformers are also available.

The analog and trip I/O are pre-defined for basic use and come standard with one binary input module

and one binary output module.

The binary I/O can be added at the time of ordering, depending on the needs of the application.

the other signals need to be set up according to the needs of the different applications.

ABB The RET670 via the binary input channels

Trip and alarm signals from the pressure relief, Buchholz and temperature devices can be

sent directly to the RET670 via the binary input channels for alarm and standby.

The binary inputs are highly stable against interference and prevent incorrect operation due to,

for example, capacitive discharges in the DC system or DC ground faults.

The distance protection function serves as backup protection against faults within the transformer and in

the connected power system.

Positive-, negative- and zero-sequence overcurrent functions (selectable direction and/or voltage control)

provide further back-up protection.

Thermal overload, overexcitation, overvoltage/undervoltage and overfrequency/underfrequency

protection functions are also provided.

A circuit breaker fault protection function for each transformer circuit breaker allows high-speed backup

tripping of surrounding circuit breakers.

A built-in disturbance and event recorder provides the user with valuable data on status and operation

for post-fault disturbance analysis.

The RET670 can also be optionally equipped with a full range of control and interlocking features,

including a synchronization check function for integration of primary or local standby control functions.

ABB Transformer protection RET670

The wide application flexibility makes this product

an excellent choice for both new installations and

the refurbishment of existing installations.

Six packages have been defined for the following

applications:

• Transformer back-up protection (A10)

• Voltage control (A25)

• Two-winding transformer in single breaker

arrangements (A30)

•Two-winding transformer in multi breaker

arrangements (B30)

•Three-winding transformer in single breaker

arrangements (A40)

•Three-winding transformer in multi breaker

arrangements (B40)

Optional functions are not configured but a

maximum configuration with all optional functions

are available as template in the graphical

configuration tool. An alternative for

Autotransformers is also available as a

configuration template. Analog and tripping IO

has been pre-defined for basic use on the, as

standard supplied one binary input module and

one binary output module. Add binary I/O as

required for your application at ordering. Other

signals need to be applied as required for each application.

Search for products

Back to Top
Product has been added to your cart