Meggitt The VMS 830-2 vibration monitor

DESCRIPTION

The VMS 830-2 vibration monitor from Meggitt’s

vibro-meter® product line is a dedicated vibration

monitor for use in vibration measurement chains.

The VMS 830-2 is a two-channel vibration monitor

that measures vibration displacement (PEAK)

and/or vibration velocity (RMS), using industrystandard velocity sensors.

Each VMS 830-2 measurement channel is

independently configurable to measure

displacement or velocity. Each channel provides

one 0 or 4 to 20 mA current loop output and a

buffered “Raw” voltage output signal. Further, for

each measurement, two alarms (Alert andDanger) and three relays (OK, Alert and Danger)

are supported. The alarms/relays are easily userconfigurable using potentiometers and DIP

switches. The VMS 830-2 also features LCD displays

to show measurement values.

Meggitt VibroSmart® VSB300 monitoring module

VSV301 monitoring module

The VSV301 monitoring module performs the data

acquisition and all of the signal processing

(filtering, analog-to-digital conversion, time and

frequency domain processing, and resampling)

required to produce processed outputs and

extracted data for physical output and data

presentation in VibroSight and VibroSight Scope.

This includes spectral band extractions,

advanced FFT analysis, trending and limit checks

(alarm and sensor OK), and run-up / run-down acquisition.

In addition, the VSV301 module has four basic

and two advanced logic functions that can be

used to combine local alarm and status

information in order to drive the module’s relays.

This local information and the logic function

outputs can also be used as inputs to the basic

logic functions of a VSI010 communications

interface module in the same measurement block.

Like all VibroSmart modules, the VSV301 module is

fully software configurable using the VibroSight

software. Using VibroSight Configurator, a module

can be configured to capture data continuously

at scheduled intervals or on the detection of an

alarm condition. In addition, spectral resolution,

frequency bandwidth, windowing function and

averaging are all fully configurable.

Using VibroSight Vision, an extensive catalogue of

plots is available for the visualisation and analysis

of measurement data.

Meggitt VibroSmart® VSV301 + VSB300 monitoring module

SPECIFICATIONS

Supported sensors

Currently available :Compatible with a range of sensors and signal conditioners using

2-wire current transmission and 3-wire voltage transmission

Dynamic input channels

Number of independent channels : 2

Measurement range

•Voltage (AC+DC) : ± 3 or ± 30 VPEAK

•Current : 15 or 150 mA

Frequency bandwidth (−0.1 dB) : 0.1 Hz to 19 kHz

•Analog high-pass filter :An optional (software configurable) analog high-pass filter can be

added to the AC path to configure the high-pass cutoff frequency

(−3 dB) as 0.1. 1.0 or 3.0 Hz.

This filter can also be disabled to allow DC-coupling of the input.

Input impedance

•Voltage : ≥ 100 kΩ, between the differential (high and low) inputs

•Current : 202 Ω ± 3 Ω, between the differential (high and low) inputs

Accuracy

•Amplitude : ≤ 1% of input FSD (measurement bandwidth from 10 Hz to 1 kHz)

•Phase : ≤ 1.5 ° (measurement bandwidth from 10 Hz to 1 kHz)

Signal to noise ration (SNR) : ≥ 80 dB (measurement bandwidth from 10 Hz to 2 kHz)

Common-mode voltage (CMV) range : ± 5 V

Common-mode rejection ratio (CMRR) :> 60 dB (at 50 / 60 Hz)

Crosstalk attenuation : Typically 60 dB

Auxiliary input channel – used as a tachometer input

Triggering method :Crossing of threshold on rising edge of signal

Triggering threshold (rising edge) : 2/3 of peak-peak value

Voltage range : ± 30 VRMS / ± 42.4 VAC ( PEAK )  or  60 VDC

Meggitt VSV301 monitoring module Applications information

Applications information

The VSV301 monitoring module is ideal for

monitoring, protecting, analysing and diagnosing

critical assets such as gas turbines, steam turbines,

hydro turbines and other rotating machines. A

VSV301 can be used as a stand-alone module or

as part of a more comprehensive monitoring

system operating with a VibroSight Server (and

data repository).

VibroSmart® systems (VSV30x + VSB300,

VSI010 + VSB010 and VSN010) conform to the

IEC 61850-3 requirements for power plant and

utility applications – when installed in specific

configurations. Contact Meggitt SA and/or refer

to the VibroSmart® distributed monitoring system

(DMS) hardware manual for further information.

For specific applications and other information,

contact your local Meggitt representative.

Meggitt The VibroSight software supports the configuration

Software

The VibroSight software supports the

configuration and operation of VibroSmart

modules, including the storage, display and/or

further processing of VSV30x data for analysis. For

example, measurements (dynamic or static) can

be logged to a VibroSight Server data repository

and/or displayed in the VibroSight Vision software.

The VibroSight Vision plot catalogue includes

static plots such as Bar chart, Spider, Table, Trend,

Bode, Polar, Correlation and Shaft Centerline,

and dynamic plots such as Waveform, Long

Waveform, Polar Waveform, Orbit, Corbit,

Spectrum and Full Spectrum, Waterfall/Cascade,

and Full Waterfall/Cascade.

In addition, the VibroSmart Tools edition of

VibroSight is a special reduced functionality

(lower cost) version of the software with a

simplified user interface that is intended for use

with VibroSmart systems only. This edition is

capable of handling live data for static

measurements directly from VibroSmart system

(that is, it is not possible to connect to a VibroSight

Server).

Refer to the VibroSight® machinery monitoring

system software data sheet for further information.

Meggitt VibroSmart® VSV301 + VSB300 monitoring module

Security

The VSV301 + VSB300 support a module lock

feature that can be used to limit the functionality

of a VibroSmart® distributed monitoring system

(DMS), as required. Enabling module lock, for a

module, measurement block or system, helps to

reduce the possibility of interference in the

operation of the monitoring system itself and in

the machinery being monitored.

Accordingly, VibroSmart® security (module lock)

makes it easier for operators to comply with

international security / critical infrastructure

regulations. Refer to the VibroSmart® distributed

monitoring system (DMS) hardware manual for

further information.

Meggitt VibroSmart® VSV301 + VSB300 monitoring module Communications

Communications

All VibroSmart modules and devices

communicate using a system bus (SBUS), based

on Ethernet technology, that supports data

transfer rates of 100 Mbps at distances up to

100 m. The SBUS ensures the transfer of both nonreal-

time (standard) and real-time (time critical)

information between VibroSmart modules, and

supports communication with the host computer

running the VibroSight software.

VibroSmart modules can either be located sideby-

side (adjacent to each other) or separate

from one another. This flexibility allows the

functionality of the monitoring system to be

distributed depending on the size of and access

to the machinery being monitored. It also helps

reduce the expensive sensor cabling typically

required between sensors and monitoring

modules, by effectively replacing it with lower

cost Ethernet and power supply cabling.

VibroSmart modules that are located side-by-side

can communicate directly (no Ethernet cabling

required) using the sidebus connectors on the

terminal base that support both SBUS and

redundant power supply distribution. VibroSmart

modules that are mounted separate from one

another can communicate over standard and

redundant Ethernet networks of shielded twistedpair

Ethernet cable using the Ethernet connectors

on the terminal base. However, using these

Ethernet connectors does require that the power

supply is distributed separately.

Discrete signal interface (DSI) inputs, including the

module lock signal, and tachometer signals can

be connected directly to individual modules

(locally). Alternatively, to reduce external wiring,

these signals can be connected to a single

VibroSmart module and shared among modules

in the same measurement block using the SBUS.

Meggitt VibroSmart® distributed monitoring system

DESCRIPTION

Introduction

The VibroSmart® distributed monitoring system

(DMS) is a system of modular and scalable

products designed for condition monitoring and

machinery protection applications for power

generation turbines, oil and gas applications and

auxiliary balance-of-plant equipment.

VibroSmart® modules can be mounted directly

on machinery, reducing the need for expensive

cabling, because they are designed and certified

to work in extremes, such as harsh industrial

environments characterized by potentially

explosive atmospheres (Ex Zone 2), high

temperatures (70°C, 158°F) and high mechanical

stress. VibroSmart® complements the VM600 series

of rack-based solutions from Meggitt’s

vibro-meter® product line and is compatible with

the same VibroSight® machinery monitoring

system software.

The VibroSmart® VSV301 monitoring module has

two independent dynamic vibration channels

and one auxiliary channel, that can be

configured as either a tachometer or a DC input

channel. The VSV301 module is capable of standalone

vibration monitoring or can be integrated

with other VibroSmart modules to create a larger

system with more measurement channels and features.

GE Bus Interface Unit Power Supply


Bus Interface Unit Power Supply

The 24 VDC power supply in the Bus Interface Unit provides power for the Bus

Interface Unit itself and logic power for all I/O modules that may potentially be installed

at that station. External power must be supplied for field wiring of input and output

devices. Specifications for the BIU power supply are listed on page 1-11.

The BIU power supply is not damaged by either of the following:

Reversing input voltage on terminals 1 and 2.

Temporary overcurrent conditions on the 6.5 VDC output.

Timing

The Bus Interface Unit provides power to all I/O modules that are installed at the station.

I/O module operation is governed by a System Reset signal to ensure controlled

operation during the power up and shut down processes. As shown in the timing

diagram below, momentary power losses of less than 10 milliseconds do not affect I/O

module operation; however, longer power losses generate a Reset for all system I/O

modules.

GE Profibus Bus Interface Unit

Profibus Bus Interface Unit

The Profibus Bus Interface Unit is a small, rugged, intelligent module with a sturdy

aluminum housing. The module has three status LEDs and a connector for a Hand-held

Programmer.

The Bus Interface Unit requires an external source of 24 VDC power.

The BIU’s internal power supply provides power for the operation of the BIU itself, and

logic power for the I/O modules connected to it.

It mounts on a separate terminal block, to which it and all field wiring are attached. The

configuration is stored in non-volatile memory located in the terminal block.

The Bus Interface Unit has a replaceable 1A, 5x20mm 250VAC slow-blow fuse on the

input power lines. The fuse can be changed without disturbing the wiring of any other

modules.