Typical Applications
• Foodservice equipment
• Industrial machinery
• Medical equipment
• Packaging equipment
• Plastics processing equipment
Specifications
Controller
• Microprocessor based, limit controller
• Customer defined hysteresis, model number
dependent
• High limit, factory selectable
• Automatic reset on power loss
• Input filter time: 1 second
Thermocouple Sensor Input
• Ungrounded
• Type J and K thermocouple types
• >10 MΩ input impedance
Input Accuracy Span Range
• Type J: 0 to 764°F (-18 to 406°C)
• Type K: 0 to 999°F (-18 to 537°C)
• Calibration accuracy: ±6°C, ±1° at standard conditions
and actual calibration ambient
• Temperature stability: ±0.3 degree per degree change
in ambient
Allowable Operating Ranges
• Type J: 32 to 626°F (0 to 330°C)
• Type K: 32 to 820°F (0 to 438°C)
Output Types
• Electromechanical relay, Form A, minimum load
current: 100mA, 8A resistive load, 120VA pilot duty,
120/240VAC maximum, inductive, electrical life 6,000
cycles at rated current
Terminals
• 0.25 in. (6.4 mm) quick connect, push-on terminals
Agency Approvals
• UL® / EN 60730-1, 2, 9 automatic electronic controls
for household and similar use. File #E43684
• UL® 1998 software review class B
• W.E.E.E.; CE – see Declaration of Conformity
• RoHS directive (2011-65-EU)
Leave a comment
Your email address will not be published. Required fields are marked *