Chemically Resistant Versions

For steam turbine applications where lube oil contains harsh chemical contaminants (ammonia, hydrogen

sulfide, etc.), a chemically resistant version of the QuickTrip has been developed. Chemically resistant

versions feature best-in-class seals in all wetted locations within the trip block assembly. Chemically

resistant versions provide an optimal solution for extreme chemical resistance while still maintaining

QuickTrip operating pressure and temperature ranges. Please contact Woodward for available models

and information regarding chemical resistance for specific applications.

Rotary Trip Valves

All three of the QuickTrip’s trip valves are spring return, two position rotary valves. When any of the

hydraulic valves is in its closed position, the ports in the valve are blocked preventing hydraulic flow

through the valve. As a valve rotates to the tripped position, the ports open and the trip header pressure

is connected to either the drain, or the inlet ports of another one of the valves. The combined action of the

three valves results in trip header pressure being connected to drain only when 2 or 3 valves are tripped.

If the unit detects any shutdown condition or loss of power occurs, the trip valve return springs will force

the valves to the fail-safe / tripped position.