Welcome to the official website of CNIACS Automation Technology Co., Ltd!

ABB SPAJ 140 C Series Technology summary Integrated solution

The legendary SP ACOM family: More than 300,000 relays in use world-wide

The SPAJ 140 Series relays belong to the SPACOM product family –

already a legend in its field. These products were the first in the worldin intro ducing a substation

automation concept based on a genuine communicating microprocessorcontrolled relay solution.

Today, these products still keep pace with the same enduring protection power.

SPAJ 140 C Series Technology summary Integrated solution

Three-phase overcurrent unit and sensitive non-directional earth-fault unit with flexible

tripping and signalling facilities and an integrated circuit-breaker failure protection.

Standard or specific

Four standard inverse definite minimum time (IDMT) time-current curves as per

IEC and BS. Two specific inverse-time characteristics called RI and RXIDG.

Recorded memory for measured fault parameters.

Local and/or remote access to parameters, fault register, events and diagnostic data through local

man-machine interface or remote serial port.

Two or three operation stages in each protection relay module.

Freely configurable output relays for tripping and signalling.

Direct numerical readout display for a full set of measured and recorded values,

indications and status information.

ABB A world-class relay collection for optimised protection functions

A world-class relay collection for optimised protection functions

The SPAJ 140 C Series relays serve your network with reliable and versatile technical features:

– The SPAJ 140 C relay comprises a reliable basic relay solution for non-directional overcurrent and

earth-fault protection.

– The SPAJ 141 C relay includes a very sensitive earth-fault input circuit.

– The SPAJ 142 C is a version of SPAJ 140 C with more sensitive earth-fault protection.

– The SPAJ 144 C is the newest member of SPAJ 140 C Series with enhanced protection functionality

and even more protective stages.

The external control input in SPAJ 140 C Series relays enables you to build busbar protection and other

special applications based on blocked overcurrent relays.

Also for off-shore applications IP54 class water- and dustproof aluminium

case endures mechanical stress.

All in one No external auxiliary relays for tripping are needed.

Wide auxiliary voltage ranges 18-80 V DC and 80-265 V AC/DC

Improved reliability and availability supported by built-in self-supervision

system with auto-diagnosis.

Long life-time MTBF higher than 200 years based on delivery and fault statistics.

CE marking according to the EC directive for EMC.

ABB SPAJ 140 C Series Combined Overcurrent and Earth-fault Relays

Enduring protection

…technology…

The SPAJ 140 Series of Combined Overcurrent and Earth-fault Relays provides your mediumvoltage

network with an optimised composition of protection functions within one relay.

This compact package facilitates combined phase and neutral current relay functions for use

with selective short-circuit and time-overcurrent protection of distribution feeders.

It can also be applied to feeder earth-fault protection in solidly earthed,

resistance earthed and isolated neutral networks.

Completely

…field-proven…

As multi-function solutions, these relays can be flexibly adapted to different kinds of

incoming and outgoing feeders in varying substation environments.You can also use

the SPAJ 140 Series relays for protection of transformers, motors and generators, and as

back-up protection.

Reliable

…through the years…

With numerous years of service in different applications world-wide, the SPAJ 140 Series

Relays serve you with a proven track record of reliability.

ABB PANEL 800 VERSION 6.2

The Panel 800 family comprises of user-friendly,

intuitive and ergonomic operator panels that combine slim,

space-saving dimensions with a comprehensive range of advanced functions.

Designed to make process automation easy,

all panels are equipped with advanced functionality for

process and equipment control, maneuvered by just touching the LCD display.

ABB Compact Product Suite Panel 800 Version 6

Panel 800 Version 6 is a user-friendly, intuitive and ergonomic

operator panel that combines slim, space saving dimensions

with a comprehensive range of advanced functions.

It is equipped with advanced functionalities for

process and equipment control accessible via touch-screen symbols.

DEIF AGC-4 Patent-pending Emulation

Patent-pending Emulation

A standard in the Automatic Genset Controller, AGC

4. using DEIF’s Emulation Solution, all you need to do

to perform a complete test of your Power Management

Systems is turn on your controller and connect communications.

The Emulations Solution’s focus on exact reproduction

of behaviour improves your planning, commissioning

and training. It is all done in a safe environment without

the costly and excessive need of gensets and switchgear

and without the risk of equipment damage and human

injury. The innovative solution gives you a critical market

advantage and guarantees your customers a cutting

edge, finished result.

Remote communication and control

The AGC-4 supports serial communication protocols

including Modbus (RS-485. USB, and TCP/IP) and

Profibus. This feature allows you to supervise and control

your genset/plant from a remote location and minimise

downtime or take immediate action on genset alarms or warnings.

DEIF Automatic Genset Controller AGC-4 features

AGC-4 features

► Multiple operating modes in one software

► Synchronisation of up to 56 breakers in one plant

► Multi-master power management

► Load-dependent start and stop

► Load management

► Emulation for fast training and I/O test

► Hot Standby – change to backup genset controller on the fly

► Close Before Excitation – synchronisation in less than 10 seconds

Remote communication and control

The AGC-4 supports serial communication protocols

including Modbus (RS-485. USB, and TCP/IP) and

Profibus. This feature allows you to supervise and control

your genset/plant from a remote location and minimise

downtime or take immediate action on genset alarms or warnings.

DEIF Automatic Genset Controller AGC-4

DEIF’s Automatic Genset Controller (AGC-4) is the

most comprehensive and flexible power management

and protection unit on the market today. A further

development of DEIF’s AGC-3. the new generation

controller is fully compatible with its predecessor and has

been designed to allow for easy, intuitive, and smooth

switch-overs for those looking to upgrade.

Suitable for a wide range of applications, the AGC-4’s

standard sequences include back-up power, start/stop,

synchronisation, and load sharing.

The AGC-4 is simple to incorporate into both new and

existing designs, customising the application to fit your

needs, for instance dedicating specific functions or logic

conditions to different inputs and outputs.

Technologically sophisticated, the AGC-4 is also the

world’s most robust power management controller,

successfully tested to maintain reliability and durability

in extreme weather and hazardous conditions. Approvals

include TÜV and UL.

Emerson KJ4002X1-BE1 Top Extender Cable Assembly

Removal and Insertion

This unit cannot be removed or inserted with system

power energized.

Power must be de-energized before disconnecting

any carriers or LocalBus Extender cables.

This product must not be unplugged unless either

the system has been de-energized or the area is

known to be safe. No combination of I/O carriers and

LocalBus Extenders must exceed a length of 6.5

meters. Interconnecting cable between enclosures

must be in conduit.

Maintenance and Adjustment

This unit contains no user serviceable parts and

should not be disassembled for any reason.

Calibration is not required.

Emerson PMCspan PMC Expansion Mezzanine Specifications

Specifications

ForM FaCTor

Single-slot 6U VMEbus format

PCI-To-PCI InTErFaCE

Controller:  PLX6150 PCI-to-PCI interface bridge

Address/Data:  A32/D32

PCI Bus Clock:  33 MHz

Signaling:  5V

Mating Connector on Host Board:  114-pin PCI

Expansion Connector; still allows use of host CPU’s

original PMCs

Compliance:  PCI Local Bus Specification, Revision 2.1

IEEE P1386.1 PCI MEzzanInE CarD SloTS

Address/Data:  A32/D32. PMC PN1. PN2. PN4

connectors

PCI Bus Clock:  33 MHz

Signaling:  5V

Power:  +3.3V, +5V, ±12V, 7.5 watts max. per PMC

Module Types:  Two single-wide or one double-

wide, front- panel or P2 I/O

P2 PMC I/O:  64 I/O signals from first PMC routed

to VMEbus P2 connector

PowEr rEquIrEMEnTS (no PMCS InSTallED)

Power:    +5V @ 0.44 ampere (max.)

+12V @ 0 ampere (max.)

–12V @ 0 ampere (max.)