Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Watlow The EZ-ZONE RM controller simplifies thermal system management

The EZ-ZONE RM controller simplifies thermal system

management. The EZ-ZONE RM controller family is

comprised of six module types: An integrated on-off or

PID control, monitoring and over/under temperature limit

module, a high-density on-off or PID control module,

a high-density limit only module, an input/output (I/O)

expansion module, a high-density monitor/scanner

module and a data logging and field communications

access module. A system is configured by connecting

any combination of module types to address specific

application needs. The EZ-ZONE RM is extremely flexible

and scalable allowing mixing and matching of I/O to

configure one to 152 control loops and up to 256

monitor points.

Now Watlow’s EZ-ZONE RM is available through

Watlow SELECT®, a program that enables you to quickly

identify, configure and receive your thermal products

faster and easier than ever before. 

Optional integrated controller functions can be

combined or ordered in different quantities:

• PID control loops

• Over/under temperature limit control loops

• 10 and 15 ampere power output/heater driver options

• On-board data logging

• Current measurement input

• Sequencer start up and control function

• Programmable timer and counter functions

• Programmable math and logic options

• Multiple communication protocol options

• Mobile configuration with removable secure digital (SD)

flash card

Watlow PM LEGACY™ series Serial Communications

Controller

• User selectable heat/cool, on-off, P, PI, PD, PID or

alarm action, not valid for limit controllers

• Auto-tune with control algorithm

• Control sampling rates: Input = 10Hz, outputs = 10Hz

• Input and output capacity per controller type ordering

information

Serial Communications

• Isolated communications

• Standard bus configuration protocol

Wiring Termination—Touch-Safe Terminals

• Input, power and controller output terminals are touch

safe removable 12 to 22 AWG

Universal Input

• Thermocouple, grounded or ungrounded sensors,

greater than 20MΩ input impedance, 2kΩ source

resistance max.

• Non-isolated to switched dc and process output

• RTD 2- or 3-wire, platinum, 100Ω @ 0°C calibration to

DIN curve (0.00385 Ω/Ω/°C)

• Process, 4-20mA @ 100Ω, or 0-10VDC @ 20kΩ input

impedance; scalable

Watlow High-amperage power control output (1/16 DIN only)

High-amperage power control output (1/16 DIN only)

• Drives 15 ampere resistive loads direct

• Reduces component count

• Saves panel space and simplifies wiring

• Reduces cost of ownership

PM LEGACY™

Specifications

Line Voltage/Power

• 85 to 264VAC, 47 to 63Hz

• 20 to 28VAC, +10/-15%; 50/60Hz, ±5%

• 12 to 40VDC

• 10VA (1/32 and 1/16 DIN)

• Data retention upon power failure via non-volatile

memory

• Compliant SEMI F47-0200, Figure R1-1 voltage sag

requirements @ 24VAC or higher

Environment

• 0 to 149°F (-18 to 65°C) operating temperature

• -40 to 185°F (-40 to 85°C) storage temperature

• 0 to 90% RH, non-condensing

Accuracy

• Calibration accuracy and sensor conformity: ±0.1%

of span, ±1°C @ the calibrated ambient temperature

and rated line voltage

• Type S: 0.2%

• Type T below -50°C: 0.2%

• Calibration ambient temperature @ 77°F ±5°F

(25°C ±3°C)

• Accuracy span: 1000°F (540°C) min.

• Temperature stability: ±0.1°F/°F (±0.1°C/°C) rise in

ambient max.

Agency Approvals

• cULus® UL®/EN/CSA C22.2 No 61010-1 Listed,

File E185611

• CSA C22.2 No. 24, File 158031

• UL® 50 4X indoor locations, NEMA 4X, IP66,

IP67 front seal

• cULus® ANSI/ISA 12.12.01-2007, CSA-C22.2 No.

213-1987, Class 1, Div. 2, Groups A, B, C and D,

temperature code T4A, File E184390 (optional)

• CE, RoHS by design, W.E.E.E.

• FM Class 3545 (limit controls)

Watlow The PM LEGACY™ series panel mount controller

The PM LEGACY™ series panel mount controller is an

industry leading PID controller that allows optimal performance

utilizing simple control and menu functionality

without complex features. It is ideally suited for basic

applications and usage levels.

The LEGACY includes one universal input and an option

for up to two outputs and is available in 1/32. and 1/16

DIN panel mount packages. It can be ordered as a PID

process controller or as a dedicated over and under-temperature

limit controller.

Agency approvals: UL® listed, CSA, CE, RoHS,

W.E.E.E., FM, SEMI F47-0200. Class 1. Div. 2 rating

on selected models

• Assures prompt product acceptance

• Reduces end product documentation costs

P3T armor sealing system

• Complies to NEMA 4X, IP66 and IP67 specifications

• Allows controller to be cleaned and washed

• Certified UL® 50 independent to NEMA 4X

specification

Consistent Termination Labeling (CTL) connection

system

• Simplifies switching between products

• Speeds up user’s system documentation

Three-year warranty

• Demonstrates Watlow’s reliability and product support

Watlow The PM LEGACY™ series Features and Benefits

Features and Benefits

Simplified menu

• Fits basic applications with a user-friendly interface

supported by two menus and a streamlined list of

parameters

• Eliminates user complexity often experienced with

more advanced controllers and unnecessary features

• Reduces user training costs and user programming

errors

PID auto-tune

• Provides auto-tune for fast, efficient start-up

Standard bus communications

• Allows easy product configuration via PC

communications protocol and free software

• Saves time, simplifies programming process and

improves reliability of controller setup

Factory Mutual (FM) approved over and under limit

with auxiliary outputs

• Increases user and equipment safety for over and

under-temperature conditions

Touch-safe package

• Increases installer and operator safety

• Complies with IP2X requirements

EZ-LINK™ mobile application for iPhone® and

Android™

• Expedites controller setup with intuitive navigation

• Simplifies setting parameters with plain text names and

descriptions

• Connects quickly and easily via Bluetooth® wireless

communications

SMOOTH TOUCH™ keypad

• Eliminates contamination points on the front of the

controller

• Prevents premature failure of mechanical components

• Creates a better seal on front panel

• Ensures an easy to clean surface

Watlow EZ-ZONE® Specifications for Basic Remote User Interface (RUI)

Specifications for Basic Remote User Interface (RUI)

Operator Interface

• Dual 4 digit, 7 segment LED displays

• Forward, backward, up and down keys plus a customer

programmable function key – EZ key

• Typical display update rate: 1Hz

• Agency approved to IP65/NEMA 4X

• Standard bus (ships with all units). Options:

EIA 232/485 Modbus® RTU, EtherNet/IP™/TCP Modbus®

or DeviceNet™, PROFIBUS DP

Line Voltage/Power

• 100 to 240VAC, +10/-15%; (85-264VAC) 50/60Hz, ±5%

• 24VAC/VDC, +10/-15%; 50/60Hz, ±5%

Agency Approvals

• UL®, CSA, CE, RoHS, W.E.E.E.

Watlow EZ-ZONE® Features and Benefits

EZ-ZONE® Remote User Interface (RUI) Provides Keypad and Display

Access to Parameters in EZ-ZONE RMs and EZ-ZONE STs and Features

Communication Gateway Options

Features and Benefits

Ability to communicate with programmable logic controller

(PLC), personal computer (PC) or operator interface (OIT)

• Optional EIA 485 Modbus® RTU

• RUI/communications gateway with optional EIA 232/485

Modbus® RTU, EtherNet IP™/TCP Modbus®, DeviceNet™ or

PROFIBUS DP

Provides user interface for EZ-ZONE products

• Supports menu navigation and access to parameter settings

in EZ-ZONE RM modules and EZ-ZONE ST controllers

User-customizable EZ key

• Executes the user-selected EZ key option in the selected

device

Supports EZ-ZONE password protection

• Presents menus from connected EZ-ZONE products

according to the customizable read and write lock settings

and requires password if that feature is enabled in the

product

YOKOGAWA EJA110E Self Diagnostics

Self Diagnostics

CPU failure, hardware failure, configuration error,

and over-range error for differential pressure, static

pressure and capsule temperature.

User-configurable process high/low alarm for

differential pressure and static pressure is also

available.

Signal Characterizer (Output signal code D, J and Q)

User-configurable 10-segment signal characterizer

for 4 to 20 mA output.

SIL Certification

EJA-E series transmitters except Fieldbus,

PROFIBUS PA and 1-5V DC with HART (Low Power)

communication types are certified in compliance with

the following standards;

IEC 61508: 2010;

Functional Safety of Electrical/electronic/

programmable electronic related systems; SIL 2

capability for single transmitter use, SIL 3 capability

for dual transmitter use.

Reliability Data different depending on hardware and

software revision.

For details, refer to Functional Safety Data Sheet.

(Document number: TI 01C25A05-01EN or TI

01C25A05-21EN for option code SLT )

The document can be downloaded from the website

of Yokogawa.

YOKOGAWA EJA110E Diff erential Pressure Transmitter

The high performance diff erential pressure transmitter

EJA110E features single crystal silicon resonant

sensor and is suitable to measure liquid, gas, or

steam fl ow as well as liquid level, density and

pressure. EJA110E outputs a 4 to 20 mA DC signal

corresponding to the measured diff erential pressure.

Its accurate and stable sensor can also measure the

static pressure which can be shown on the integral

indicator or remotely monitored via BRAIN or HART

communications. Other key features include quick

response, remote set-up using communications and

self-diagnostics. FOUNDATION Fieldbus, PROFIBUS

PA and 1 to 5 V DC with HART (Low Power) protocol

types are also available. EJA-E series models in

their standard confi guration, with the exception of

the Fieldbus, PROFIBUS and Low Power types,

are certifi ed as complying with SIL 2 for safety

requirement.

 STANDARD SPECIFICATIONS

Refer to GS 01C31T02-01EN for Fieldbus

communication type and GS 01C31T04-01EN for

PROFIBUS PA communication type for the items

marked with “◊.”

□ PERFORMANCE SPECIFICATIONS

Zero-based calibrated span, linear output, wetted

parts material code S and silicone oil, unless

otherwise mentioned.

For Fieldbus and PROFIBUS PA communication

types, use calibrated range instead of span in the

following specifi cations.

Specifi cation Conformance

EJA-E series ensures specifi cation conformance to at

least ±3σ.

Reference Accuracy of Calibrated Span

(includes terminal-based linearity, hysteresis, and

repeatability)

YOKOGAWA AXF Flexible Electrical Connection Direction

■FEATURES

• User-oriented Functionality Fluid Adhesion Level Diagnosis

By constantly monitoring the level of insulating

substance on the electrodes, it is possible to determine

when maintenance is required.

With the utilization of an optional replaceable electrode,

the electrodes can be easily removed from the flowmeter

and cleaned.

• Flexible Electrical Connection Direction

The converter or the terminal box can be rotated

arbitrarily to change the directions of electrical

connection on the site.

• Clear and Versatile Indications

The LCD indicator employs a large, backlit full dot

matrix, that can facilitate various displays.

One to three lines are available. When there is an alarm

condition, a full description of the countermeasure is

indicated.

“Easy Setup” Parameters “ ”

The most frequently used parameters are arranged in a

group at the top.

The infra-red switches enable the users to set

parameters without opening the cover.

● Expansion of Product Lineup

Search for products

Back to Top
Product has been added to your cart