CTI 2590-A 16-Point Isolated Discrete Output Module

Description

The 2590-A 16-point Isolated Discrete Output Module

provides sixteen discrete isolated outputs from the CTI

2500 Series®or Simatic® 505 I/O base. The module

uses solid- state output circuits to switch on or off ex

ternal devices such as pilot lamps, motor starters, or

solenoids. The 2590-A is designed to switch externally

supplied 20 to 132 VAC. The internal logic signals are

isolated from the external outputs to 1500 VDC.

Features

• CTI 2500 Series®  base format

• 2.0 Amps per output (no derating)

• Isolated 1500 VDC channel-to-channel

• Blown fuse reporting (per channel) to the PLC

• Blown fuse indicator

• Logs in as a 16Y or 16X/16Y (jumper selectable)

• Individual fuse for each output channel

• Single-wide module

CTI 2589-B Specifications

Specifications

Inputs per Module: 8. 16 or 32

Classic

Isolation: 1500 VDC channel-to-backplane

1500 VDC group-to-group

Input Voltage:

Range Setting

12/24V range

48V range

110V range

220VAC range

Operating Range

11 – 30 volts

40 – 56 volts

79 – 132 volts

164 – 240 volts

*NOTE: 220V range is AC only

Input Current: AC: 2.1—3.6 mA

DC: 2.5—4.3 mA

Operating Characteristics for Typical Input:

AC Voltage Input:

Turn ON Time:    4.0mS

Turn OFF Time:    15.0mS

DC Voltage Input:

Turn ON Time:    1.0mS

Turn OFF Time:    15.0mS

Connector: 2500-40F Removable Connector (sold

separately)

Wire Gauge: 14-22 AWG

Backplane Power: 3.6 Watts max.

Module Size:  Single-wide

Operating Temperature: 0° to 60°C

(32° to 140°F)

Storage Temperature:  -40° to 85°C

(-40° to 185°F)

Relative Humidity:  5% to 95%

(non-condensing)

Shipping Weight:  1.5lb (0.68 Kg)

Voltage Range Selection Jumpers

The 2589-B will handle a wide range of AC and DC signals,

and has incorporated the ability to select either 12V/24V, 48V,

110V, or 220V on a per channel basis using jumper selection.

The selections are made individually for each of the 32

channels using jumpers. However, the same voltage range

must be selected for all channels in the same group. The

operating ranges are as follows:

Range Setting

12/24V range

48V range

110V range

220VAC range

Operating Range

11 – 30 volts

40 – 56 volts

79 – 132 volts

164 – 240 volts

* NOTE: 220V range is AC only

CTI 2589-B 8/16/32-Point Universal Discrete Input Module

Description

The 2589-B 8/16/32-Point Universal Discrete Input

Module accepts a wide range of voltage signals. It is

designed to accept both AC and DC voltage allowing

the user to pick and choose ranges on a single

module. The 2589-B can be configured as an 8-point,

16-point, or 32-point module and can replace many

Siemens® input products with no rewiring. Motor

centers, optical sensors, limit switches and utility

control are excellent examples of applications for this

product.

Features

• CTI 2500 Series® or Simatic® 505 base format

• 8. 16. or 32 universal input points

• Replaces Siemens® 505-4008-A, 4016-A, 4032-A,

4208-A, 4216-A, 4232-A, 4308. 4316. 4316-A, 4332.

4408-A, 4416-A, 4432-A with no rewiring

• 1500V channel-to-PLC backplane and group-to

group isolation

• Wide 11V to 220V AC/DC range (selectable by

group)

• Isolation in groups of 4 or 8 (selectable on 2589-B)

• Sourcing or sinking inputs

• Single-wide module

CTI 2588-8 8-Point Universal Input Module

Description

The 2588-8 8-Point Universal Discrete Input Module

accepts a wide range of voltage signals. It is de-

signed to accept both AC and DC voltage allowing

the user to pick and choose ranges on a single

module. The 2588-8 can replace Siemens® 8 point

input products with no rewiring. Motor centers,

optical sensors, limit switches and utility control are

excellent examples of applications for this product.

Features

• CTI 2500 Series® or Simatic® 505 base format

• 8 universal input points

• Replaces Siemens® 505-4008-A, 4208-A, 4308.

and 4408-A with no rewiring

Product Bulletin

• 1500V channel-to-PLC backplane and group-to

group isolation

• Wide 11V to 220V AC/DC range (selectable by

group)

• Isolation in groups of 2

• Sourcing or sinking inputs

• Single-wide module

Specifications

Inputs per Module: 8

Isolation:

1500 VDC channel-to-backplane

1500 VDC group-to-group

Input Voltage:

Range Setting

Classic

Operating Range

12/24V range 11 – 30 volts

48V range

110V range

220V range

164 – 240 volts

Input Current:

AC: 2.1 – 3.6 mA

DC: 2.5 – 4.3 mA

Operating Characteristics for Typical Input:

AC Voltage Input:

Turn ON Time: 4.0mS

Turn OFF Time: 15.0mS

DC Voltage Input:

Turn ON Time: 1.0mS

Turn OFF Time: 15.0mS

Connector: Removable

Wire Gauge: 14 – 22 AWG

Backplane Power: 1.8 Watts max.

Module Size: Single-wide

Shipping Weight: 1.5 lb. (0.68 Kg)

Additional Product Information:

On CTI’s Website you will find links to the 2500 Series

Standard Environmental Specifications and the UL

Agency Certificates of Compliance .

CTI 2585 Word and Discrete Mode

Word and Discrete Mode

The 2585 may operate as a 16 Bit Word Input Module or as a 16 Dis

crete Input Module. By setting JP1 in Word Mode and using Workshop

to configure I/O the 2585 will look like a standard WX input module; for

example WX1-WX8.

NOTE: The 2585 will be mapped as the first WX address (i.e. WX1). In

Word Mode Channel 1 corresponds to bit 16 or LSB and Channel 16

corresponds to Bit 1 or MSB.

Note:

If the address line is blank or erroneous, re

check the module to ensure that it is firmly

seated in the slots. Generate the PLC I/O

configuration chart again. If the address

line is still incorrect, contact your local dis

tributor or CTI at 1-800-537-8398 for fur

ther assistance.

Changing Operating Modes

Any time the operating mode of the 2585 is

changed with JP1. the module must be con

figured in the PLC. Failure to do so may

cause unpredictable operation due to the

fact that the PLC uses different methods of

addressing discrete modules from word

modules.

CTI 2585 16-point TTL Input Module

Description

The 2585 16-Point TTL Input Module accepts sixteen

TTL driven inputs to the CTI 2500 SeriesTM or

Simatic® 505 Series I/O base. The inputs are

isolated channel-to-channel.

The 2585 has an input voltage range from 2.6 to 28

VDC; therefore, the inputs may be driven by CMOS

and open collector transistor devices.

Features

• CTI 2500 Series and Simatic 505 base format

• 500 V channel-to-channel isolation

• 1500 V channel-to-PLC backplane isolation

Specifications

Inputs per module: 16

Isolation:

500 VDC channel-to-channel

1500 VDC channel-to-backplane

Input Voltage:

2.6 to 28 VDC

TTL OFF <0.8 VDC TTL ON > 2.6 VDC

1500 VDC channel-to-backplane

Input Current:

20 mA max. per circuit (0.5 mA @ 2.6 VDC)

Isolation:1500 VDC channel-to-backplane

Turn ON Time: Approx. 1 mSec nominal

Turn OFF Time: Approx. 2 mSec nominal PLC

Reporting:  X or WX (jumper selectable)

Wire gauge: 14-22 AWG removable connectors

Backplane power: 1.4 Watts (all outputs active)

Module size: Single-wide

Blown fuse indication: Front panel LED

Shipping Weight: 1.5 lb. (0.68 Kg)

Additional Product Information:

On CTI’s Website you find will links to the 2500

Series  Std Environmental Specifications and the UL

Agency Certificates of Compliance .

CTI 2576 DeviceNet™ Scanner Module

Product Summary

The 2576 DeviceNet Scanner is a SIMATIC® 505

module that enables the PLC to access devices on a

DeviceNet network. The 2576 module writes data

supplied by the PLC to DeviceNet devices and obtains

data from these devices and presents it to the PLC as

standard I/O.

Since DeviceNet data appears to the PLC as standard

data types, no special PLC programming techniques are

required to access the DeviceNet devices. Using a CTI

supplied configuration program, the user can specify

how device data will appear to the PLC. Inputs from

the device may be mapped to X, WX, or V memory

locations. Outputs to the device may be mapped to Y,

WY, or V memory locations.

To maximize performance and provide maximum

flexibility, the 2576 logs into the PLC as two I/O slots –

a high-density I/O slot and a special function slot. The

high-density I/O interface provides 32 discrete-in (X),

32 discrete-out (Y), 32 word-in (WX) and 32 word-out

(WY) data points.  The Special Function interface can

transfer up to 480 words per PLC scan. It can also be

used by the PLC to send special commands to the module.

The module DeviceNet port can operate at baud rates

up to 500Kb.  A serial port provides a means to

download configuration record and software updates.

The front panel includes a complete set of LEDs that

display module and DeviceNet status.  The module also

includes a DeviceNet power tap, which allows the user

to connect a power supply to the network.

CTI 2576 allows a 2500 Series® PLC to read I/O devices on a DeviceNet™ network

The 2576 allows a 2500 Series® PLC to read I/O devices on a DeviceNet™ network.

The module provides one DeviceNet™ channel which can attach up to 63 network

devices. Multiple modules can coexist in the same I/O chassis.

Features

• DeviceNet™ points appear as a standard PLC I/O

• RS-232 serial port enables configuration of module and network devices

• Front panel LEDs allow monitoring of module and network devices

• Built-in power tap can be used to power DeviceNet™ network

Files & Documents

• Product Maturity Announcement

• Product Bulletin

Manuals

• User Manual V1.2

Application Notes

• Getting Started with the 2576 DeviceNet Scanner and Cutler-Hammer Motor Starters

Alfa Laval PureBallast 3 Ultra Minimized power consumption

Superior Performance in any waters and challenging

conditions

PureBallast 3 Ultra offers unmatched biological disinfection

performance in any type of water: fresh, brackish or marine.

This includes liquid water at sub-zero temperatures. When

operating in IMO-regulated areas with brackish or marine

water, it maintains full flow where the UV transmittance is as

low as 42%.

In addition, PureBallast 3 Ultra is prepared for challenging

water with high sediment levels. An upgraded filter design with

a faster gear motor improves the backflushing efficiency,

which significantly reduces the risk of filter clogging.

Minimized power consumption

An expanded range of UV reactor sizes ensures a close

match between PureBallast 3 Ultra and the ballast pump

capacity. For certain flows, this reduces power needs by up to

19% over previous systems.

In all configurations, automatic power management minimizes

the energy consumption. With this feature, PureBallast 3 Ultra

runs at just 50% of its potential operating power in many

situations. Yet it can ramp up to full power to maintain flow in

challenging waters. By supporting higher flow rates,

PureBallast 3 Ultra uses less energy than competing systems

in relation to the ballast water volume.

Alfa Laval PureBallast 3 Ultra can be used in all water types – fresh,brackish or marine

Application

PureBallast 3 Ultra is a modular, inline system for the

biological disinfection of ballast water. Using PureBallast 3

technology that has been type approved by IMO and the U.S.

Coast Guard (USCG), it removes organisms in accordance

with set limits.

PureBallast 3 Ultra can be used in all water types – fresh,

brackish or marine. With its enhanced UV treatment, it also

provides unmatched disinfection performance in low-clarity

water. Moreover, its upgraded filter design provides greater

protection against clogging.

PureBallast 3 Ultra uses the same treatment technology as

type-approved PureBallast 3 systems. Updated type

approvals are in progress due to the new configurations.

Benefits

• Superior Performance in any waters and challenging

conditions

• Minimized power consumption

• Easy installation with minimized footprint

• Delivered Connectivity-ready

• Designed and supported for the whole vessel lifetime

Search for products

Back to Top
Product has been added to your cart