Honeywell Touchpoint Plus Flexible Capabilities

Flexible Capabilities

 • Compatible with the full range  of Honeywell gas detectors

 • Powered audiovisual alarms  simplify field installation

 • Configuration includes easy  grouping and voting alarm logic without specialist knowledge

 • Next-generation compatibility 

• Optional Modbus output for integration with a higher level system

The full-color stoplight-style status indication provides clarity from a distance too.

Touchpoint Plus features a comprehensive set of outputs as standard,

including common alarms and dedicated drives for remote audiovisual indicators.

Its modularity enables you to customize your system to meet your specific application requirements.

Selecting the right detector for use with your controller can deliver significant

savings in startup costs and ongoing operations. 

Our global partner network and dedicated application specialists are

able to help you make the right choices for your industry.

With everything at your fingertips, you can take ownership of your system

and operate it with confidence, helping to ensure the safety of your people and the productivity of your

site.

ABB PGC5000 Safety area classification

Safety area classification

Class I, Division 1. Group B, C, D with Type X-Purge

Temperature Code T2 or T3

Ex Zone 1

CE 0344; II 2G; Ex db eb ib pxb IIB+H2 T2 or T3  Gb;

Conforms to EU Directives 2014/34/EU (ATEX), 2014/30/

EU (EMC) and 2014/35/EU (LVD)

EU Type Certificate LCIE 09ATEX 3006X

IECEx Certificate LCI09.0010X

Enclosure purge wait time

18.2 minutes

Power (hot, neutral, ground)

Voltage

100 VAC ± 10%

120 VAC ± 10%

230 VAC ± 10%

Frequency

50/60 Hz ± 10%

Power Consumption

1900 VA (maximum start-up)

1000 VA (steady-state)

Instrument air

Supply connection

3/8 inch tube, minimum

Supply pressure

552 to 690 kPa (80-100 psig)

Quality

Instrument grade

Clean, oil free and -34 °C, (-30 °F) dewpoint

An optional air clean up unit is available for FID burner air.

Flow rates

Startup

378 l / min (13.4 ft3/min)

Steady state

310 l / min (11 ft3 / min)

Oven Cool-down

628 l / min (22.25 ft3 / min) During vortex cool-down

ABB PGC5000 TP Gas Chromatograph

Description

An isothermal oven contains the temperature programmed

oven assembly with a detector, either a Flame Ionization

Detector (FID) or Thermal Conductivity Detector (TCD). The

detector is mounted on top of the temperature programmed

oven, and it is integrated with the TP oven in order to provide

an optimal analytical flow path and eliminate potential cold

spots. The sample valves, either a Liquid Sample Valve (LSV)

or a Continuous Performance (CP) valve, can also be installed

in the isothermal oven compartment. An optional air

cleanup / methanizer unit may be used. Special columns

(capillary or packed type) are installed inside the temperature

programmed oven. The columns contain special packing

material which separates the compounds to be analyzed so

that they enter the detector in a predictable sequence.

Specialty analysis for separation of wide boiling range

compounds. The PGC5000 Temperature Programmed (TP)

Gas Chromatograph uses component separation to analyze

gas or liquid samples. The analyzer operates unattended,

automatically sampling and analyzing process streams.

ABB PGC5000 Temperature Programmed (TP) Gas Chromatograph

Introduction

Specialty analysis for separation of wide boiling range

compounds. The PGC5000 Temperature Programmed (TP)

Gas Chromatograph uses component separation to analyze

gas or liquid samples. The analyzer operates unattended,

automatically sampling and analyzing process streams.

Physical

Environmental (enclosure)

Protected from weather:  IP 54. (NEMA Type 13) equivalent

Ambient temperature range

0 to +50 °C (32 to 122 °F)

Humidity

95% relative humidity, non-condensing

Dimensions (W x D x H)

496 x 340 x 1175 mm

(19.5 x 13.4 x 46.3 in.)

Weight

73 kg (160 lb) (minimum)

Mounting

Wall: 32 mm (1.3 in.) from wall with brackets

Floor: Optional wheeled dolly

EMI/RFI considerations

Conforms to Class A industrial environment

Electrical entries

Left side

Pneumatic entries

Right side

Sample entries

Liquid

Right side, 1 each model 791 LSV

Gas

Bottom and/or right side

Vents

Bottom and/or right side

ABB PGC5000A gas chromatographs Safety area classification

Safety area classification

CSA / NRTL

Class I, Division 1; gas groups B, C, D with type Y-purge

Class I, Division 2; gas groups B, C, D Temperature Code T4

ATEX / IECEx/ CN / KO

Zone 1: CE; II2G, Ex ib py IIB+H2 T4 Gb

Zone 2: CE; II3G Ex nA IIB+H2 T4 Gb

CU TR: INMETRO

Optional X-purge power interlock Ex d ib px IIB+H2 T4

Purge wait time

18.2 minutes (Class I, Division 1 / Zone 1 area)

(hot, neutral, ground)

Power (hot, neutral, ground)

Voltage: 100 to 240 VAC

Frequency: 50 to 60 Hz

Power consumption: 120 VA startup and steady-state

operation (variable with installed options)

Instrument air

Supply connection: ¼ inch tube, minimum

Supply pressure: 414 kPa (60 psig) minimum

Quality: Clean, oil free and –34° C, ( –30° F) dew point

Instrument grade:

Flow rates – steady state purge

2 to 25 l / min (0.75 to 0.78 ft3 / min) at 20° C,

Y-purge types

ABB PGC5000 Series gas chromatographs PGC5000A

Application flexibility

• PGC5000B Smart Ovens target basic applications

with a fixed set of features

• PGC5000C Smart Ovens target complex

applications requiring multiple detectors for high

application density

• PGC5007 oven targets flare gas monitoring and

total sulfur process applications

• PGC5009 oven designed for fast temperature

programmed simulated distillation analysis

Specification

Master controller

Environmental (enclosure)

Protected from weather

IP 54. (NEMA 3 equivalent)

Ambient temperature range

0 to 50° C (32 to 122° F)

Humidity

95% relative humidity, non-condensing

Dimensions (W x D x H)

596.9 mm x 419.1 mm x 256.5 mm

(23.5 in. x 16.5 in. x 10.1 in.)

Weight

20 kg (44 lbs) (minimum, configuration dependent)

Mounting

Wall: 33 mm (1.3 in.) from wall with brackets

Floor

Optional dolly with casters

EMI / RFI considerations

Conform to class A industrial environment

Electrical entries

Top

ABB PGC5000 Series Multiple configurations

Features

Ease of use

• Graphics based touch screen HMI

Multiple configurations

• Supports multiple Smart OvenTM configurations,

•  Up to 4 PGC5000B ovens

• Up to 2 PGC5000C ovens

• One PGC5000C with up to 2 PGC5000B ovens

Communication interfaces

• Listing_01: Nempello qui tem dolestiuria

– Listing_02:, qui ipsa volupta

• Ethernet, OPC, MODBUS, 4 to 20mA analog

outputs, VistaNET 2.0 compatible

– Nempello qui tem dolestiuria dolenimus

– Meniasperrum quuntem

Enhanced Data Storage

– Cia iumendaest, qui ipsa volupta

• Nempello qui tem dolestiuria dolenimus

• Up to 7 days of chromatograms and reports via

removable SSD card

• Meniasperrum quuntem

Standard inputs / outputs

• Eight isolated 4 to 20mA outputs – Four digital outputs

– Dedicated purge alarm

Dolupta arum velia volenimus disci temqui offic

tentiorrum quis atquiberis doluptatem non pore,

Sendus dolut que illorio quod quundem

quunduciatia pre modis quam quunduciatia premodis

– Dedicated common malfunction alarm

• Two additional configurable outputs

ABB PGC5000 Series gas chromatographs PGC5000A

The new standard in industrial gas chromatographs

Measurement made easy

Overview

The PGC5000A Generation 2 master controller

provides all analyzer system control functions and

coordinates internal and external data activities for

all of the PGC5000 Series ovens. The new controller

also supports multiple smart oven configurations to

maximize application flexibility while minimizing

space and utility requirements. The Generation 2

controller is designed with a Real Time (embedded)

Operating System (RTOS) to guarantee critical

system uptime, security and deterministic transfer

of data. The Human Machine Interface (HMI)

includes a 10.4 inch true color touchscreen SVGA

display, universal keypad and touch-pad mouse.

ABB PGC5000 Backwards compatibility and legacy interfacing

Backwards compatibility and legacy interfacing

This interface is supported on the PGC5000 Direct Modbus

TCP from the VistaGateway Modbus Client application, and

OPC server application. If you use a VistaGateway, you only

have to write to one set of registers or OPC tag. If you are

writing direct to the PGC5000 then you must write to each

PGC5000’s Modbus interface because each PGC5000 acts

as a Modbus slave.

If you have legacy instruments (such as the model 3100 or

PGC2000 Series) then you must use a VistaGateway or a

Modbus enabled router. However, the Modbus enabled router

does not support the PGC5000 but you can write through the

Modbus enabled router to the PGC5000 using the Ethernet

switch with the PGC5000 being the actual Modbus slave.

Honeywell BW™ ICON Multi-Gas Detector

FEATURES AND BENEFITS

RELIABLE

Two months of battery runtime on a 4.5-hour charge

— and up to four months if you turn off the detector at the end of each shift.

No daily charging, no unexpected downtime.

EASY TO MANAGE

The IntelliFlash™ green light indicates when the detector is in compliance

and the amber light indicates the need for maintenance.

COMPATIBLE

The Honeywell BW™ Icon is compatible with the IntelliDoX instrument management

system and Honeywell Safety Suite and also with TouchConnect™ using Bluetooth® for 

wireless configuration.

RESPONSIVE

1series sensors respond to dangerous gas levels in seconds, even in harsh temperatures.

ACCURATE

Low-power infrared LEL sensor is immune to silicone poisoning,

which means accurate monitoring of combustibles.

EASY TO USE

Small, lightweight and wearable.  One-button operation.

Honeywell BW™ Icon Technical Specifications

Search for products

Back to Top
Product has been added to your cart