Woodward QuickTrip Electro-Hydraulic Trip Block Assembly Input Power

Input Power

The QuickTrip requires a power source capable of supplying the necessary output voltage and current

at full transient conditions. The maximum power in watts (W) of a DC source can be calculated by

multiplying the rated output voltage by the maximum output current capability. The calculated power

rating of the supply should be greater than or equal to QuickTrip requirements. The electrical power

supply should be able to provide 8 A (or 2.6 A per channel) at 24 VDC continuously.

Cable selection and sizing is critical to avoid power loss during operation. The power supply

input at the electronic module input terminal must always provide the required nominal voltage to operate

the valve.

The input power wires must comply with local code requirements and be of sufficient size such that the

power supply voltage minus the IR loss in the two lead wires to the QuickTrip valve electronics module

does not drop below the input minimum voltage requirement.

The QuickTrip is not equipped with an input power disconnect. A means of disconnecting input power to

the QuickTrip must be provided for safe installation and servicing.

The QuickTrip is not equipped with input power protection. A means of protecting input power to the

QuickTrip must be provided. Breakers or fuses are intended to protect installation wiring and power

sources from faults in the QuickTrip or wiring. A circuit breaker meeting the requirements listed in the

table below, or a separate protection with the appropriate ratings, may be used for this purpose.

Circuit protection, which isolates both positive and negative leads, is recommended.

Refer to the table below for recommended fuse ratings or circuit breakers.

ABB AX411/511010 Conductivity Transmitter

• Cost effective

– select one or two conductivity inputs or

combine conductivity and pH/Redox (ORP) in

one analyzer

– integral PID controller (AX410)

• Reduced installation cost

– easy access terminations; reduced panel space

• High functionality at minimum cost

– conductivity, resistivity, difference, ratio,

%passage, % rejection and inferred pH calculations

• Expanded monitoring and control

– add-on option board provides a total of five

alarm relays and four current outputs

– service logbook providing historical data

• Energy saving

– high visibility, backlit display with auto switch-off function

• Reduced yearly maintenance costs

– 30V DC option negates the need for costly safety tests

• Wide range of applicability

– water and waste water treatment

– power, pure water

– semiconductors

– chemicals

– pharmaceuticals

– pulp & pape

The AX400 Series

The AX400 analyzers incorporate the latest technology to

provide highly reliable, flexible, feature-packed devices that

satisfy a diverse range of process monitoring and control

applications. The complete range encompasses solutions for

pH/Redox (ORP), conductivity and dissolved oxygen.

Models AX41x and AX45x enable continuous measurements of

one or two low-level conductivity points with simultaneous local

display and retransmission. The analyzers are used with ABB

2-electrode conductivity cells providing measurements with

exceptional accuracy and performance.

Model AX45x analyzers are dedicated to United States

Pharmacopoeia <645>.

AX400 Series analyzers are available for either wall-/pipe- or

panel-mounting and are rated to IP66 (NEMA4X).

Model Numbers about ABB AX410. AX411. AX416. AX450 and AX455 series:

AX410/10001;AX410/50001;AX410/100010/STD;AX411/10001;AX411/500010/STD;

AX416/10001;AX416/50001;AX430/10001;AX460/10001;AX411/10001;

AX431/10001;AX461/10001;AX413/10001;AX433/10001;AX463/10001;

AX436/10001;AX466/10001;AX410/20001;AX430/20001;AX460/20001;AX410/15001;

AX430/15001;AX460/15001;AX410/16001;AX430/16001;AX460/16001;

AX416/50001;AX410.2.0.0.0.1;AX400-0295;AX400-0365;AX410/1000C;AX410/10101;

AX410/50001;AX410/5000C;AX410/5200C;AX410/500010/STD;AX416/50001;

AX430/1000C;AX430/5000C;AX430/20001/STD;AX433/11001;AX460/10001;

AX460/1000C;AX460/10101;AX460/2000C;AX460/5000C;AX460/5200C;AX466/1000C;

AX466/5000C;