Woodward Special Ambient Temperature Considerations
Special Ambient Temperature Considerations
Cold Start Procedure:
If performing a cold-start of QuickTrip in very cold ambient environment conditions
(temperatures between -40 °C to +15 °C), both the hydraulic oil within the QuickTrip manifold and the QuickTrip manifold itself
must undergo a warmup procedure prior to starting the turbine to ensure the QuickTrip will operate within
specified performance limits. In particular, slew open times increase at lower hydraulic fluid temperatures
due to the higher viscosity (lower fluidity) of the hydraulic oil.
General
Woodward products covered under Woodward Product and Service Warranty (5-09-0690) are warranted
to be free from defects in materials and workmanship, when installed and used in the manner for which
they are intended, for a period of 18 months from the date of shipment from Woodward, defined in
Woodward’s Terms and Conditions.
Repairs and servicing of the QuickTrip must be performed by Woodward or its authorized service facilities
Use of a cable gland or stopping plug that does not meet the hazardous area certification requirements or
thread form or thread size will invalidate the suitability for hazardous locations.
Never remove or alter the nameplate as it bears important information which may be necessary to service
or repair the unit.
QuickTrip Cover Replacement Kit
Servo cover replacement kit may be ordered from Woodward.
Refer to Figure 5-1a which displays the part number. The location and assembly orientation of each kit
component must be installed as depicted in Figure 5-1b using a spanner wrench or Woodward tool
#1013-6603. For additional information see QuickTrip Field Repair Procedure Manual 26842.