Woodward EGCP-3 Generator Protective Features

Generator Protective Features

• Over/Under Voltage (27.59)

• Over/Under Frequency (81O,81U)

• Directional (Forward/Reverse) Power (32)*

• Negative Phase Sequence Overcurrent (46)

• Negative Phase Sequence Overvoltage (47)

• Phase Overcurrent (51)*

• Directional VAR

• Phase Current Differential Imbalance (87)*

• Speed/Frequency Mismatch

• Load Surge

Utility Protective Features

• Over/Under Voltage (27.59)

• Over/Under Frequency (81O,81U)

• Directional (Forward/Reverse) Power (32)*

• Negative Phase Sequence Overcurrent (46)

• Negative Phase Sequence Overvoltage (47)

• Phase Overcurrent (51)*

• Voltage Restrained Phase Overcurrent (51V)*

• Directional VAR

• Phase Current Differential Imbalance (87)*

• Loss of Mains/Loss of Mains with Alarm

*—Inverse Time Protections implemented are according to IEEE C37.112 “Very Inverse” curves

Woodward EGCP-3 Generator System Control Package Functions

Reactive kVAR Control

• VAR (PF) sharing on isolated busses using percentage based reactive load sharing

• Voltage bias signal to AVR configurable for discrete raise/lower,4–20 mA, ±1. ±3. or ±9 Vdc

• Power factor or VAR control when base loaded

• Externally adjustable VAR or PF setpoint levels

• Manual voltage control capability

• Configurable load/unload ramp rates

Synchronizing

• Phase match or slip frequency synchronization with voltage matching

• Full three-phase sensing on both busses

• Manual synchronization capability

• Adjustable phase window, voltage window, reclose attempts, reclose timing

• Safe dead bus closing logic internal to the control

• Synch check (25)

• Breakers or contactors

Automatic Unit Sequencing

• Automatically starts and stops gen-sets based on plant bus demand

• Automatic generator set loading and unloading for bumpless transfer

• Configurable plant bus demand startstop levels and timers

• Configurable generator priority sequencing

Communications

• Modbus® RTU or DDE communications via RS232 (1 each) and RS-232/422/485 (2 each) serial ports

• Echelon® TP/XF-1250 network

• CAN 2.0b Network (OEM option only)

Woodward Custom OEM Configurations

Custom OEM Configurations

Among the many EGCP-3 control functions are:

Engine Control/Protection

• Configurable start sequencing

• kVA-controlled cool-down timer

• Oil pressure monitoring (idle/rated)

• Coolant temperature monitoring

• Battery voltage monitoring

• Speed monitoring with overspeed protection

Real kW Load Control

• True RMS power calculations

• Load bias signal to engine speed control, configurable for ±3 Vdc, 0–5

Vdc, 500 Hz PWM, 4–20 mA, discrete raise/lower

• Configurable loadunload ramp rates

• Isochronous load-sharing of up to 16 EGCP-3 units using percentage based load sharing

• Built-in import/export control

• Soft utility transfer function

• Externally adjustable load or process references

Woodward EGCP-3 is available in standard configurations

DESCRIPTION

EGCP-3 is available in standard configurations including:

DR—Distributed Resource:

• Single unit isolated

• Single unit parallel to mains

• Single unit ATS

LS—Load Share:

• Multiple unit isolated

• Multiple unit parallel to mains

MC—Master Controller:

• Mains tie breaker control

• Inter-bus tie breaker control

Features

• Complete generator system control package

• Automatic load demand sequencing of multiple units

• Three-phase synchronization

• Comprehensive system protection –engine, utility, and generator

• Revenue-grade power and energy metering

• Digital display of engine, generator, and system data

• Real kW and reactive kVAR load sharing and control

• Additional on board and distributed I/O available

• Easily adapts to exact application needs with GAP™ programming tools

• Advanced network communications

• DSLC™ compatible

• Built-in diagnostics

Woodward EGCP-3 is a powerful microprocessor based generator system control

APPLICATIONS

EGCP-3 is a powerful microprocessor based generator system control and

management package designed for the most demanding power generation applications.

EGCP-3 combines engine, generator, power system, switchgear, and utility monitoring,

protection, and control functions in a single, compact, and cost-effective package.

Perfect for medium- and large-sized generation systems, the EGCP-3 is designed 

for use in stand-alone, peaking, or utility paralleled systems.

Up to 16 EGCP-3 controls can be networked together to provide total system

control, including multiple utility and  inter-bus tie breakers.

DESCRIPTION

EGCP-3 is available in standard configurations including:

DR—Distributed Resource:

• Single unit isolated

• Single unit parallel to mains

• Single unit ATS

LS—Load Share:

• Multiple unit isolated

• Multiple unit parallel to mains

MC—Master Controller:

• Mains tie breaker control

• Inter-bus tie breaker control

Woodward EGCP‐3 LS and SPM‐D on the Yacht Sea Jewel Application

Application

The ship’s chief engineer required several modes of operation in order to

optimize the performance of the yacht’s electrical system.

During normal operation, the load on the ship can be supplied by one genset, but when seas are

rough and the ship’s stabilizers are running, there is a need for additional generation.

In this mode of operation, both gensets must run continuously.

Also, the ship needs to be connected to shore power when in port.

In order to eliminate a blackout on the ship during the power transfer,

and to reduce the amount of load generated to the shore power,

a scheme was developed to provide an automatic closed transition using a Woodward SPM‐D.

Using the sequencing functionality of the EGCP‐3. the control is configured to

start an additional unit two seconds after the load on the master unit exceeds 75%.

When the load reduces to below 30%, the slave unit is removed from the system after 60 seconds.

The controls needs to be able to trade master/slave relationships,

so a switch is used to place one control in Auto and Run w/ Load (Master)

and the second unit in Auto (Slave). Both controls have the option to operate in either

mode—so if sequencing needs to be avoided, the operator can place both

controls in Auto and Run w/ Load, and both units will share the entire electrical load.

Woodward EGCP‐3 LS and SPM‐D on the Yacht Sea Jewel

Sea Jewel is a 160 ft (49 m) yacht that uses two Caterpillar 3304 gensets for electric

power. The ship’s original control system needed repair but had been discontinued;

additionally Lloyd’s registration was required to comply with new insurance

guidelines. So Sea Jewel Ltd contacted Governor Control Systems Inc. (GCS) to

purchase, install, and commission two Woodward EGCP‐3 LS units to control these

two Cat gensets. The EGCP‐3 LS combines engine, generator, power system,

switchgear, bus and generator monitoring, protection, and control functions in a

single, compact, and cost‐effective package. Woodward representatives were

present to help in the commissioning.

Electrical System

The Sea Jewel’s two Cat 3304 gensets are rated for 80 kW each. Each genset is

controlled by a Woodward EGCP‐3 LS and can connect to the ship electrical load via

its generator breaker. The load can also be supplied by shore power when in port.

To synchronize the boat to shore power, a Woodward SPM‐D delivers

synchronization signals to the two EGCP‐3 LS units and closes the breaker when

phase and frequency are matched.

Conclusions

The commissioning of the Sea Jewel was a success, and operation of an EGCP‐3 and SPM‐D illustrated the

adaptability of Woodward controls to any application. By applying the EGCP‐3 LS units to the control of

the Cat gensets and the SPM‐D for synchronizing the shore power, the Sea Jewel now has a reliable

system to begin their chartering business this summer. Woodward would like to thank Sea Jewel Ltd and

Governor Control Systems for their time and energy on this project and congratulates them on a great

control system.

ABB REC 670 Current protection

Current protection

Instantaneous phase overcurrent protection (PIOC, 50)

The instantaneous three phase overcurrent function has a low transient overreach and short tripping

time to allow use as a high set short-circuit protection function, with the reach limited to less than

typical eighty percent of the power line at minimum source impedance.

Four step phase overcurrent protection (POCM, 51_67)

The four step phase overcurrent function has an inverse or definite time delay independent for each

step separately.

All IEC and ANSI time delayed characteristics are available together with an optional user defined

time characteristic.

The function can be set to be directional or non-directional independently for each of the steps.

Instantaneous residual overcurrent protection (PIOC, 50N)

The single input overcurrent function has a low transient overreach and short tripping times to

allow use as a high set short circuit protection function, with the reach limited to less than typical

eighty percent of the power line at minimum source impedance. The function can be configured

to measure the residual current from the three phase current inputs or the current from a separate

current input.

ABB REC 670 Bay control IED Differential protection

Functionality

Differential protection

High impedance differential protection(PDIF, 87)

The high impedance differential protection can be used when the involved CT cores have same turn

ratio and similar magnetizing characteristic. It utilizes an external summation of the phases and neu

tral current and a series resistor and a voltage dependent resistor externally to the relay.

The single input overcurrent function has a low transient overreach and short tripping times to

allow use as a high set short circuit protection function, with the reach limited to less than typical

eighty percent of the power line at minimum source impedance. The function can be configured

to measure the residual current from the three phase current inputs or the current from a separate

current input.

Four step residual overcurrent protection (PEFM, 51N/67N)

The four step single input overcurrent function has an inverse or definite time delay independent for

each step separately.

All IEC and ANSI time delayed characteristics are available together with an optional user

defined characteristic.

ABB REC 670 A number of protection functions are available for flexibility

High set instantaneous phase and earth overcur rent, 4 step directional or un-directional delayed

phase and earth overcurrent, thermal overload and two step under and overvoltage functions are

examples of the available functions allowing user to fulfill any application requirement.

Disturbance recording and fault locator are avail able to allow independent post-fault analysis after

primary disturbances with a single failure in the protection system.

6 x 32 dual directional channels for intertrip and binary signals transfer is available in the commu

nication between selected IEDs inside the station or in a near-by station.

The advanced logic capability, where the user logic is prepared with a graphical tool, allows spe

cial applications such as automatic opening of disconnectors in multi-breaker arrangements, closing

of breaker rings, load transfer logics etc. The graphical configuration tool ensures simple and

fast testing and commissioning.

Serial data communication is via optical connections to ensure immunity against disturbances.

The wide application flexibility makes this product an excellent choice for both new installations and

the refurbishment of existing installations.