Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Vibro-Meter VM600Mk2/VM600 ABE056 Slimline Racks OVERVIEW


SPECIFICATIONS

OVERVIEW

Housing: Painted galvanized steel sheet

Color: Off-white (RAL 9002)

Power supply: Integrated RPS1U power supply for VM600Mk2/VM600

The integrated RPS1U power supply provides +5 VDC and ±12 VDC for the VM600Mk2/VM600 and all installed modules (cards).

See also AC Input Power on page 3 and DC Input Power on page 3.

Power Input: The power input has an AC or DC connector (with RFI filter) and an on/off switch.

See Ordering Information on page 6 for information on the main power cord (power strip).

Backplane: Proprietary VM600Mk2/VM600 rack bus (open collector (OC) bus) for data/signal sharing between modules (cards)

Rack Slots (module (card) locations):

Front of rack:

– 1 × slot – module (card) position 01 – for handling modules (cards) such as MPC4Mk2. XMx16. MPC4. or AMC8.

Rear of rack:

– 1 × Slot – Module (Card) Position 01 – For associated input/output modules (cards) such as IOC4Mk2. XIO16T, IOC4T or IOC8T.

– 1 × slot – module (card) position 00 – for the relevant relay module (card), e.g. RLC16Mk2 or RLC16.

Vibro-Meter VM600Mk2/VM600 ABE056 Slimline Racks Applications


The rack has an integrated backplane that provides electrical interconnection between the integrated

power supply (RPS1U) and the installed VM600Mk2/VM600 modules (cards).

The rack also has a power check relay on the rear of the rack to indicate if the integrated power supply is functioning properly.

The VM600Mk2/VM600 Processing Module (Card) is mounted at the front of the rack and the

associated Input/Output Module (Card) is mounted at the rear of the rack.

The input/output modules (cards) provide connectors for connecting sensors/measurement

chains and for sharing various signals with external systems such as DCS or PLC.

In general, the VM600Mk2/VM600 ABE056 Ultra Slim Racks are factory-configured before shipment and are therefore ready for use.

Optionally, each module (card) can be reconfigured to meet the needs of a specific machinery monitoring application.

Each module (card) can be reconfigured to meet the needs of a specific machinery

monitoring application using the appropriate software package from Meggitt Vibro-Meter: VibroSight® or VM600 MPSx.

SPECIFICATIONS

OVERVIEW

Housing: Painted galvanized steel sheet

Color: Off-white (RAL 9002)

Power supply: Integrated RPS1U power supply for VM600Mk2/VM600

The integrated RPS1U power supply provides +5 VDC and ±12 VDC for the VM600Mk2/VM600 and all installed modules (cards).

See also AC Input Power on page 3 and DC Input Power on page 3.

Power Input: The power input has an AC or DC connector (with RFI filter) and an on/off switch.

See Ordering Information on page 6 for information on the main power cord (power strip).

Backplane: Proprietary VM600Mk2/VM600 rack bus (open collector (OC) bus) for data/signal sharing between modules (cards)

Vibro-Meter VM600Mk2/VM600 ABE056 Slimline Racks

VM600 ABE056 Ultra Slim Racks

(houses the MPC4 mechanical protection card)

Key Features and Benefits

– From the vibro-meter® product family

– 19-inch slim rack with 1U standard height

– Rugged metal construction

– Modular concept allows the addition of specific modules (cards) for machine protection or condition monitoring

– Rack or panel mounting

– Backplane supports open collector (OC) bus and power distribution for VM600Mk2/VM600 systems

– Integrated AC input or DC input power supply

– Power check relay

Applications

– VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

The VM600Mk2/VM600 ABE056 slimline rack is used to house the hardware for

the VM600Mk2/VM600 series of machine protection and/or condition monitoring systems in the Vibrometer® product line.

The VM600Mk2/VM600 ABE056 slimline rack has a standard height of 1U and provides mounting

space (rack slots) for a single wide VM600Mk2/VM600 processing module (card pair) and a relay module (card).

This rack is particularly suitable for industrial environments where the equipment must be permanently installed in a 19-inch cabinet or panel.

Different versions of the integrated RPS1U power supply can power the VM600Mk2/VM600

ABE056 slimline racks from an external AC or DC power supply.

Vibro-Meter VM600 AMC8 and IOC8T Analog Monitor Card Pairs Description

Description

AMC8 Card

The AMC8 is an analog monitoring card designed for use in the VM600 rack-mounted system

in the Meggitt Vibrometer® product family for machinery monitoring and protection applications.

This versatile card is capable of measuring and monitoring up to eight analog signal inputs simultaneously.

The AMC8 card is available in two versions: a “standard” version and a “circuit independent” version,

both of which are available as card pairs using the corresponding IOC8T input/output card.

The AMC8 card is mounted on the front of the VM600 rack (ABE04x or ABE056) and the IOC8T I/O card is mounted on the rear.

Both cards connect directly to the rack backplane via two connectors.

A pair of AMC8/IOC8T cards provides eight channels of temperature monitoring that accept resistance

temperature detector (RTD) and thermocouple (TC) temperature inputs as well as process inputs.

The source and type of each channel is selectable during card configuration.

Cold Junction Compensation (CJC) sensor processing is used for the thermocouple temperature

channel and can be used for two of the eight channels, also selectable during card configuration.

All inputs are conditioned and compared to user-configurable alarms that are defined through Meggitt’s VM600 MPSx software.

A pair of AMC8/IOC8T cards is configured (i.e. operated independently) via the RS-232 port on the front panel of the relevant AMC8 card.

The AMC8 card also provides access to the CPUx card (ABE04x only) in slot 0 of the VM600 rack via the VME bus.

These interfaces allow the operator to configure the VM600 card, access measurements,

view detailed board status, upload firmware updates, and more.

The AMC8 card can drive the four local relays on the IOC8T card, as well as any of the 16 relays

on the RLC16 card using the VM600 rack’s raw bus and/or open collector (OC) bus.

These cards also provide analog signal outputs based on current (0 to 25 mA). Voltage outputs are also supported.

Application Information

The AMC8/IOC8T card pair is ideally suited for machinery monitoring and protection in a variety of industrial applications.

Vibro-Meter VM600 AMC8 and IOC8T Analog Monitor Card Pairs

Key Features and Benefits

– From the Vibro-Meter® product family

– Card Pair Provides 8 Channels of Temperature and Process Monitoring for VM600 Systems 

Provides 8 Channels of Temperature and Process Monitoring for VM600 Systems

– 8-channel software configuration capability:

Thermocouple (TC), Resistance Temperature Detector (RTD), Current and Voltage Inputs

– Analog signal inputs from 0 to 25 mA and 0 to 10 V Range of analog signal inputs

– Cold Junction Compensation (CJC) sensor processing on two optional channels

– Current output (optional voltage output)

– Programmable alarm, hazard, and OK setpoints

– Includes 4 relays that can be used for alarm signaling under software control

– Control outputs to RLC16 relay card on VM600 frame

– Front panel LEDs indicate status and alarms

– Real-time plug-in card (hot-swappable)

– Available in ‘standard’ and ‘circuit independent’ versions

Applications

– Mechanical protection and/or condition monitoring

Vibro-Meter VM600 IOC4T Input/Output Card Application

Application Information

The IOC4T, when paired with the MPC4 Machinery Protection Card, is ideally suited for

machinery monitoring and protection in a variety of industrial applications.

For more information on using the MPC4/IOC4T card pair, see

VM600 Machinery Protection System (MPS) Hardware Manual and the VM600 MPSx Software Manual.

For information on using the MPC4/IOC4T card pair in a functional safety environment, refer to the VM600 Functional Safety manual.

Parameters

Dynamic Signal Input

Filtering: Filtering to prevent electromagnetic interference (EC compliant).

Refer to the VM600 MPC4 Mechanical Protection Card datasheet for more information.

Buffered dynamic signal output

Filter: Filtered to prevent electromagnetic interference (EC compliant).

Refer to the VM600 MPC4 Machine Protection Card datasheet for more information.

Speed/phase reference input

Filter: Filtered to prevent electromagnetic interference (EC compliant).

Refer to the VM600 MPC4 Machine Protection Card datasheet for more information.

Discrete Signal Interface (DSI) inputs

Vibro-Meter VM600 IOC4T Input/Output Card Description

Description

IOC4T Card

The IOC4T Input/Output card is the signal interface for Meggitt’s VM600 series MPC4 machine protection card.

It is mounted on the rear of the VM600 rack and connects directly to the rack backplane via two connectors.

Each IOC4T card is associated with the corresponding MPC4 card and is mounted directly to the rear of the VM600 rack (ABE04x or ABE056).

The IOC4T operates in slave mode and communicates with the MPC4 through connector P2 using the Industrial Packet (IP) interface.

The front panel of the IOC4T (rear of the VM600 frame) contains terminal strip connectors

for connecting the transmission cables from the measurement chain (sensors and/or signal conditioners).

The threaded terminal connectors are also used to input all signals from any

external control system and output all signals to any external control system.

The IOC4T card protects all inputs and outputs from electromagnetic interference (EMI)

and signal surges and complies with electromagnetic compatibility (EMC) standards.

The IOC4T connects raw dynamic (vibration) and velocity signals from sensors to the MPC4.

These signals are processed and passed back to the IOC4T and made available on its front panel (rear of the VM600) terminal strip.

For dynamic signals, four on-board digital-to-analog converters (DACs) provide calibrated signal outputs in the 0 to 10 V range.

In addition, four on-board voltage-to-current converters provide current output signals in the 4 to 20 mA range (jumper optional).

The IOC4T contains four local relays that can be used for any specific alarm signal under software control.

Vibro-Meter VM600 IOC4T Input/Output Card

Key Features and Benefits

– From the Vibro-Meter® product family

– Signal interface card with 4 dynamic signal inputs and 2 tachometer (speed) inputs for MPC4 mechanical protection cards

– Screw terminal connectors for all input/output connections (48 terminals)

– Includes 4 relays that can be used for alarm signaling under software control

– 32 fully programmable open collector outputs (jumpers optional) for connection to IRC4 and RLC16 relay cards

– Buffered “raw” sensor signals and analog output signals (voltage or current) for vibration channels

– EMI protection for all inputs and outputs

– Real-time plug-in cards (hot-swappable)

– Available in “standard” and “circuit independent” versions

Applications

– Mechanical protection and/or basic condition monitoring​

Vibro-Meter VM600 Mk2 Vibration Meter Features

Features

System isolation

The VM600Mk2 uses a single type of card (MPC4Mk2) for monitoring and condition monitoring.

However, these functions are tightly segregated to ensure API 670 compliance and reduce costs.

A separate (optional) XMV16 condition monitoring card is available for applications with a large number of channels.

High channel density

The standalone VM600Mk2 protection card has 4 input channels, but each VM600 can be expanded

to a maximum of 48 input channels Mk2 racks, allowing vibration protection to be extended to the most demanding rotating machinery.

Advanced Monitoring

The stand-alone VM600Mk2 condition monitoring card offers 16 dynamic channels and 4 tachometer channels,

which can all be independently configured to provide unrivaled accuracy and reliability.

Systems

System Features

SIL 2 certified (TÜV Nord)

Hot-swappable monitor card

Suitable for accelerometers, proximity probes, speed, dynamic pressure and icing detection sensors

Suitable for integration with VibroSight analysis and data processing software

Protection card (MPC4Mk2): 4 dynamic channels and 2 auxiliary channels

Monitoring card (XMV16): 16 dynamic channels and 4 tachometer channels

Standard 19-inch 6U machine

Vibro-Meter VM600 Mk2 Vibration Meter Applications

Design

The Vibrometer VM600Mk2 is designed to provide state-of-the-art vibration monitoring and protection (SIL 2),

especially for large critical rotating machinery with high channel counts.

Its modular 19-inch card allows the user to build a system to suit specific application requirements.

In addition, the system can be integrated with VibroSight software, which provides detailed insight into the

condition of rotating machinery and a wide range of analysis options.

Applications

The VM600Mk2 is suitable for plants where rotating machinery is concentrated in one area,

requiring centralized monitoring and a high channel count.

Typical applications include:

■ Gas turbines

■ Steam turbines

■ Water turbines

Other critical rotating machinery

Search for products

Back to Top
Product has been added to your cart