GE 151X1235DB15SA03 Control Hardware

Control Hardware

The 151X1235DB15SA03 EX2100e regulator system is available in multiple configurations to

provide control flexibility for thyristor and regulator systems.

For small regulator systems, two pulse width modulation (PWM) power converter modules

use insulated gate bipolar transistors (IGBTs) to provide up to 35 A or 120 A nominal output.

These systems can support the following applications:

• Saturated current transformer/power voltage transformer (SCT/PPT) regulators

• Brushless exciter regulators

• Direct current (dc) rotary exciter regulators

In SCT/PPT regulator and dc rotary exciter regulator applications,

the EX2100e regulator system can reduce the effects of exciter time constants.

It combines direct measurement of the generator excitation voltage and excitation current to improve

response to system transients.

The architecture is a single control with a single power control module (PCM) or dual control with dual

PCMs,and includes a customer interface subsystem, optional diagnostic local operator interface (touch

screen),optional control operator interface (COI) remote touch screen interface, control power input

module, and PCM.

The PCM consists of a bridge interface subsystem, power bridge, optional AC and DC filtering networks,

and AC (ac) and/or DC isolation devices. To expand input and output (I/O) capabilities, VersaMax® or

Mark* VIe Control IONet I/O modules can be added.

GE Excitation control unit system 151X1235DB15SA03

Excitation control unit system 151X1235DB15SA03

151X1235DB15SA03 EX2100e excitation control regulator system is GE’s latest advanced control system

for steam, gas or hydroelectric generators, suitable for new units and modified units.

Control hardware and software design are closely coordinated with

GE’s system and control engineering to ensure a true system solution.

Integration between the excitation control system, turbine control system,

static start control system, integrated control system (ICS) and human machine interface (HMI) is

seamless.

For stand-alone retrofit applications, integration with the customer’s distributed control system (DCS) is

supported via serial or Modbus® Ethernet.

This document is specifically for the application of the 35 A and 120 A (nominal) series EX2100e control

regulator systems.

Control Hardware

The 151X1235DB15SA03 EX2100e regulator system is available in multiple configurations to

provide control flexibility for thyristor and regulator systems.

For small regulator systems, two pulse width modulation (PWM) power converter modules

use insulated gate bipolar transistors (IGBTs) to provide up to 35 A or 120 A nominal output.

These systems can support the following applications:

• Saturated current transformer/power voltage transformer (SCT/PPT) regulators

• Brushless exciter regulators

• Direct current (dc) rotary exciter regulators

ABB M3V4-1/0-0 64122088 Input and output module

Product Features

Advanced control algorithm: The M3V4-1/0-0 64122088 main control interface board adopts

advanced control algorithm,which can realize precise excitation control and regulation to ensure the

stable operation of the motor.

This precise control capability helps to reduce energy consumption and improve energy efficiency.

High reliability and durability: The interface board is manufactured with high-quality materials and strict

production processes,and has extremely high reliability and durability.

It can operate stably in various harsh environments and withstand challenges in fields such as industrial

automation.

PCB module M3V4-1/0-0 64122088

M3V4-1/0-0 64122088 Input and output module

Analog module M3V4-1/0-0 64122088

M3V4-1/0-0 64122088 main control interface board is an important product in the ABB series.

It is used in a wide range of applications such as industrial automation, process control,

power generation, robotics and manufacturing.

This interface board is known for its high performance, high reliability and flexibility,

and can meet the needs of various complex industrial environments.

Emerson IC694BEM320 I/O Link Interface Module

PACSystems controllers and Series 90 PLCs equipped with an I/O Link Master Module.

An I/O Link Interface Module occupies one module slot in an

RX3i backplane.  It can be installed in any available backplane slot.

The maximum number of I/O Link Interface Modules that can be

installed in the backplane depends on the power that is available

from the power supply.  To determine the exact number of

modules allowed in your system, see the information on power

supplies in chapter 3.

Usually, when there are multiple I/O Link Interface Modules in the

same RX3i system, they are on separate I/O Links.  However, it

is possible to have more than one I/O Link Interface Module in

the system connected to the same link, if that suits the needs of the application.

Module Description

The module’s front cover is removable. A jumper plug inside the front cover is used to set up the

module as a 32–point or 64–point I/O module.

Serial Ports

The front of the module has two 20–pin connectors that are used to attach the I/O Link cable.

One connector is for the cable to the previous device on the link––either the master or another

slave. The other connector is for the cable to the next slave on the link, if there is one.  See the

RX3i I/O Link Modules User’s Manual, GFK-2358 for more information. Signal levels are

RS422/485 compatible.

Emerson I/O Link Interface Module IC694BEM320

The RX3i I/O Link Interface Module operates as a slave on a

Fanuc I/O Link network.  It can exchange either 32 or 64 inputs

and outputs with the master.  Typical masters on the I/O Link

include all modern FANUC CNCs and Power Mates,

PACSystems controllers and Series 90 PLCs equipped with an

I/O Link Master Module.

An I/O Link Interface Module occupies one module slot in an

RX3i backplane.  It can be installed in any available backplane slot.

The maximum number of I/O Link Interface Modules that can be

installed in the backplane depends on the power that is available

from the power supply.  To determine the exact number of

modules allowed in your system, see the information on power

supplies in chapter 3.

Usually, when there are multiple I/O Link Interface Modules in the

same RX3i system, they are on separate I/O Links.  However, it

is possible to have more than one I/O Link Interface Module in

the system connected to the same link, if that suits the needs of

the application.

Emerson IC695EIS001-DD Ethernet IEC 104 Server Module

The PACSystems* RX3i Ethernet IEC 104 Server Module, catalog number

IC695EIS001. implements the IEC 60870-5-104 communications protocol. It

permits a PACSystems RX3i controller to be connected to an Ethernet

network using a standard TCP/IP connection scheme, allowing an IEC 104

Client to poll data from the Server, as well generate unsolicited

communications from the Server back to the Client.

Two auto-sensing 10BaseT/100BaseTX RJ-45 shielded twisted-pair Ethernet

ports permit direct connection to either a 10BaseT or 100BaseTX IEEE 802.3

network without an external transceiver. Line, Star and Daisy Chain topologies are supported.

The RX3i Ethernet IEC 104 Server Module hosts the IEC104 Server side

protocol on a common RX3i ETM001 module hardware platform. Thus, many

of the specifications and behaviors are shared with the ETM001 module

including protocol support. IC695EIS001 is an Ethernet-connected module

that fits in the RX3i backplane and permits the RX3i to behave as a Server on

the IEC104 network. The data exchanges between the EIS001 module and

IEC104 Client(s) are configurable, using a single COMMREQ instruction in the

ladder logic or Structured Text program.

Emerson IC695EIS001-DD Ethernet IEC 104 Module Features

Module Features

• Supports eight client connection to the RX3i Controller data set specified

in the configuration. [RBE supported only on one Client connection

associated with a specified port -Refer to GFK-2949B for details]

• Supports Interrogation and RBE for Single Point and Double Point data.

• Supports Interrogation and RBE for Regulated Step.

• Supports Interrogation and Measured data sets for Scaled, normalized,

and single precision Float.

• Supports 56-bit IEC 60870-5-104 time format, with the default being

56-bit time format.

• Supports Time Set, and query of the RX3i Controller CPU Clock in UTC time.

• Cause of Transmission size is two octets.

RX3i Interface specifications:

• Up to four EIS001 per RX3i, as allowed by available power and slots.

• Module can be installed in any available RX3i main rack I/O slot.

• Module supports insertion into and removal from an RX3i backplane

which is under power.

• Firmware upgrade through RX3i CPU using WinLoader software utility.

Emerson IC694DNM200 DeviceNet Cable

DeviceNet Cable

Either DeviceNet thick cable or thin cable can be used.  Thick cable permits greater cable

lengths and higher current levels. Generally, thick cable is used for the trunk cable.  Thin cable

is normally used for shorter distances and is suitable for drop cables and for installations where

more cable flexibility is needed. Both thick cable and thin cable are 5-wire, multi-conductor

copper cable.  Two wires form a transmission line for network communications. A second pair

transmits network power.  The fifth conductor forms an electromagnetic shield. Most cables

have color coded leads which correspond to the color coding on the terminals on the DeviceNet

Master Module.

Power Requirements

The DeviceNet Master module consumes 450mA at 5VDC (typical) from the PLC backplane.

This power is used for module operation, The DeviceNet Master powers its network transceiver

from the 24VDC DeviceNet network power source. Linear power supplies are recommended for

the DeviceNet power source. The DeviceNet power source should not also be used for device

power. Transients caused by  I/O devices can cause communications errors and even create

bus-off conditions.

The DeviceNet specification recommends using a power tap to connect a power supply to the

network. The power tap should be appropriately fused for the current capacity of the bus cables.

The maximum current on the network depends on the cable type.

The DeviceNet network power supply must be grounded, but only at one point.  The V- signal

must be connected to protective earth ground at the power supply only.  If multiple power

supplies are used, only one power supply must have V- connected to earth ground.

Emerson IC694DNM200 Power Requirements

Power Requirements

The DeviceNet Master module consumes 450mA at 5VDC (typical) from the PLC backplane.

This power is used for module operation, The DeviceNet Master powers its network transceiver

from the 24VDC DeviceNet network power source. Linear power supplies are recommended for

the DeviceNet power source. The DeviceNet power source should not also be used for device

power. Transients caused by  I/O devices can cause communications errors and even create

bus-off conditions.

The DeviceNet specification recommends using a power tap to connect a power supply to the

network. The power tap should be appropriately fused for the current capacity of the bus cables.

The maximum current on the network depends on the cable type.

The DeviceNet network power supply must be grounded, but only at one point.  The V- signal

must be connected to protective earth ground at the power supply only.  If multiple power

supplies are used, only one power supply must have V- connected to earth ground.

Current Limit for Thick Cable

For thick cable, the maximum current on the network is 16 Amps.  However, only 8 Amps is

permitted on a single network segment. 16 Amps can be drawn from a single power supply by

locating the power supply at the center point of two network segments, supplying 8 Amps to

each segment.

Current Limit for Thin Cable

For thin cable, the maximum current permitted is 3 Amps.

Emerson IC694DNM200 Bus Length

Bus Length

The maximum length of the trunk cable and drops both depend on the cable type and data rate.

Individual drops may not exceed 6 meters and are limited to one network node per drop.

However, the node may have multiple ports.

For each baud rate, the total drop length is the sum of all the drop lines of both cable types in

the network.

In addition, if the distance from a tap to the most distant device on its drop is longer than the

distance from the tap to the nearest terminating resistor, the drop line length also counts as part

of the trunk cable length (as well as the overall drop length).

DeviceNet Cable

Either DeviceNet thick cable or thin cable can be used.  Thick cable permits greater cable

lengths and higher current levels. Generally, thick cable is used for the trunk cable.  Thin cable

is normally used for shorter distances and is suitable for drop cables and for installations where

more cable flexibility is needed. Both thick cable and thin cable are 5-wire, multi-conductor

copper cable.  Two wires form a transmission line for network communications. A second pair

transmits network power.  The fifth conductor forms an electromagnetic shield. Most cables

have color coded leads which correspond to the color coding on the terminals on the DeviceNet

Master Module.