Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Hitachi Energy 520PSD01 Power Supply Unit

Features

The Power Supply Unit 520PSD01 has the following features and functions:

– Natural convection cooling

– Electronic power limiting at the outputs

– Short-circuit protection at the output

– Input overvoltage protection

– Reverse voltage protection on inputs

– Potential-free isolation between inputs and outputs

– LEDs to monitor output voltage

When interacting with the 520CMD01. the input voltage (24 VDC) passes through the I/O module.

During power-up, the 520CMD01 switches the 24 V output voltage to the active voltage of the I/O module.

Applications

The Power Supply Unit 520PSD01 generates or switches 24 VDC, ±15 VDC, and 5 VDC for RTU520 systems.

The output power is sufficient to power an RTU520 with up to 16 I/O modules. The input voltage to the power supply unit is 24 VDC.

Hitachi Energy 520BID01 Binary Input Module

Applications

The module 520BID01 provides 16 galvanically isolated inputs for up to 16 binary process signals.

The input signals are scanned and processed with a time resolution of up to 1 ms. The input signals can be assigned to processing functions according to configuration rules.

The input signals can be assigned to processing functions according to configuration rules.

The module 520BID01 can process the following types of signals or combinations of signals:

– 16 time-stamped single-point messages (SPI)

– 8 time-stamped double-point messages (DPI)

– 2 8-bit digital measured values (DMI8)

– 1 16-bit digital measurement (DMI16)

– 16 integrated totals (max. 25 Hz) (ITI)

– 2 step position information, 8 bits each (STI)

– 2 bit string inputs, 8 bits each (BSI8)

– 1 16-bit bit string input (BSI16)

– or a combination of these signal types

The module is available in two versions (rubrics):

– 520BID01 R0001: Process voltage 24 to 60 VDC.

There are LEDs for each input and a common loop for each of the 8 inputs.

– 520BID01 R0002: Process voltage 110 to 125 V DC.

Each input is signalled by an LED and each of the 8 inputs has a common loop.

Hitachi Energy 520BOD01 Binary Output Module

Applications

The binary output module 520BOD01 controls 8 binary process signals via relay contacts.

The output signals can be assigned to process functions according to configuration rules.

The module 520BOD01 can process the following types of signals:

– Single or dual command (SCO or DCO), 1-pole or 2-pole outputs, no checksum (n select 1).

– Single or dual commands (SCO or DCO) with 1.5- or 2-pole output, no checksum (1 of n) Single or dual commands (SCO or DCO) with 1.5- or 2-pole output, no checksum (1 of n)

– Adjustment Step Command (RCO), 1 or 2 poles

– Digital Setpoint Command, 8-bit, No Strobe (DSO8)

– Digital setpoint command, 8-bit, no strobe (DSO8) Bit-string output, 1 or 8-bit (BSO1 or BSO8)

Modules allow switching voltages up to 150 V DC or up to 8 A continuous current. 8 A continuous current.

Characteristics

Binary Outputs

The binary outputs are relay contacts.

The 8 outputs are isolated from each other. In addition, they are isolated from the internal electronics by means of an optocoupler.

All 8 relay contacts have independent outputs and there are no common circuits.

The command outputs to the process equipment can be executed either directly or in conjunction with the command output monitoring module.

The Command Output Monitoring Module checks the output circuits (1 out of n times). For more details, refer to the Command Output Monitor data sheet.

The following modules with command output monitoring functions are supported:

– 560CIG10

– 560CID11

– 520CSD01

Hitachi Energy 520AID01 Analogue Input Module

Applications

The 520AID01 module records up to 6 analogue measured values.

The module 520AID01 can process the following types of signals

Signals:

– Analogue measured values (AMI)

– Floating-point measurement information (MFI)

The following measurement ranges can be configured

520AID01 R0001:

– ± 2.5 mA

– ± 5 mA

– ± 10 mA

– ± 20 mA

The following measurement ranges can be configured as

520aid01 r0002:

– ± 1 V DC

– ± 10 V DC voltage

Additional valid ranges and real-time zero signals can be generated beyond these ranges by means of conversions in the communication unit (CMU).

The module is available in two versions (rubrics):

– R0001: Current measurement version

– R0002: Voltage measurement version

Hitachi Energy Analogue Output Module 520AOD01

Applications

Analogue control outputs for sequential or closed-loop control, display instruments, measurement recorders, etc,

The analogue output board 520AOD01 can be connected to measuring and recording instruments, etc.

The board 520AOD01 has 2 output channels which can be configured for different voltage or current output ranges.

The module 520AOD01 can process the following types of signals:

– Analogue setpoint commands

– Floating-point setpoint commands

The following output ranges can be configured independently for each channel via on-board switches:

– ± 2.5 mA

– ± 2.5 mA ± 5 mA

– ± 10 mA

– ± 20 mA (4…20 mA) .20 mA)

– ± 1.25 VDC

– ± 2.5 VDC

– ± 5 V DC

– ± 10 V DC

Output formats unipolar, bipolar or real-time zero (4 … 20 mA) are configurable via software parameters. 20 mA) can be configured via software parameters.

Hitachi Energy 520PTD01 Temperature Measurement Module (PT100)

Applications

The 520PTD01 circuit board is used for direct connection of PT100 temperature transmitters.

Up to six transmitters can be connected to the board. The measuring range is ± 200 °C.

Special features

Basic checks and calculation-intensive cyclic processing functions are already performed on the module, thus reducing the burden on the communication unit.

Relevant changes are transmitted as events via the WRB I/O bus.

The 6 differential inputs are not isolated from the RTU500 series power supply.

The 520PTD01 converts the analogue signal to 4096 steps (12 bits) and measures 100%.

The differential inputs are protected against static and dynamic overvoltage by protection circuitry. A low-pass filter suppresses non-line frequency AC interference.

Two additional channels are used for automatic zero calibration.

The line frequency is configurable in the configuration tool.

The microcontroller uses these configuration parameters to set up the A/D converter.

Hitachi Energy 520ADD01 Input/Output Adapter

520ADD01 Input/Output Adapter

DIN rail mounting base module RTU540

Expansion of wired or bus (WRB) with additional RTU520 I/O modules

Number of modules selectable via front jumper (4 or 8)

Inputs: WRB, ribbon cable

Outputs: WRB, ribbon cable

Applications

I/O adapter 520ADD01 for connecting RTU520 I/O modules to RTU520 or RTU540 communication modules

Features

The I/O adapter connects to the WRB I/O bus (wired OR bus) and automatically generates the address of the connected I/O module within the I/O assembly.

Two green LEDs on the module indicate activity on the I/O bus.

Hitachi Energy 520ADD02 Input/Output Adapter

Applications

I/O adapter 520ADD02 for connecting more than 16 RTU520 I/O modules to the

RTU520 or RTU540 to an I/O bus with RS485 or fibre optic connection.

The adapter can also be used to extend the WRB I/O bus in decentralised I/O applications.

The maximum distance is up to 2 kilometres and the distance between the I/O adapters needs to be more than 30 cm.

In addition, I/O adapter 520ADD02 can be used as a stand-alone module to extend the RTU560 I/O modules (e.g. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40).

(e.g. 23BE40. 23BE50. 23BA40) to the RTU540.

The module is available in two versions (standard)

– R0001: RS485

– R0002: RS485 and glass fibre optics, 840 nm

Features

The I/O adapter connects to the WRB I/O bus (wired OR bus)

The I/O adapter connects to the WRB I/O bus (wired OR bus) and automatically generates the address of the connected I/O module within the I/O assembly.

The I/O adapter is always the last adapter unit in Virtual I/O Chassis 1.

The adapter converts the WRB I/O bus to the SPB I/O bus (Serial Peripheral Bus) via RS485 or fibre optic connection.

The glass fibre optic module is compatible with the 23OK24 and 560FOC40 modules.

There are two green LEDs on the module to indicate activity on the I/O bus.

Hitachi Energy Input/Output Adapter 520ADD03

520ADD03 Input/Output Adapter

Converts RS485 or fiber optic connections to WRB in decentralized locations

Requires 520PSD01

Supports up to 16 I/O modules

Applications

I/O adapter 520ADD03 for connecting more than 16 RTU520 I/O modules to RTU520 or RTU540 with RS485 or fiber optic connection

or RTU540 with RS485 or fiber optic connections.

The adapter can also be used to extend the WRB I/O bus in decentralized I/O applications over distances of up to 2 km.

The distance between the I/O adapters needs to be more than 30 centimeters.

In addition, I/O adapter 520ADD03 is used to connect the RTU520 I/O module to the RTU560.

The I/O adapter is always used with the power supply unit 520PSD01.

The module is available in two versions (standard)

– R0001: RS485

– R0002: Glass fiber, 840 nm

Features

The I/O adapter is the first adapter in the DIN rail mounted I/O assembly and it starts with a new virtual rack number.

The adapter converts the SPB I/O bus (Serial Peripheral Bus) with RS485 or fiber optic connection to a WRB I/O bus.

The glass fiber optic module is compatible with the 23OK24 and 560FOC40 modules.

There are two green LEDs on the module to indicate activity on the I/O bus.

The virtual rack address is selectable via DIP switches. In addition, the adapter automatically generates I/O module addresses within the I/O assembly.

Hitachi Energy 540CID01 DIN Rail Mount Base Module

Applications

The 540CID01 is a module in the RTU540 product family consisting of a communication unit (CMU), a multiple input/output module (IOM) and a galvanically isolated wide-range power supply (IOM).

The 540CID01 is a module in the RTU540 product family consisting of a communication unit (CMU), a multi-input/output module (IOM), and a galvanically isolated wide-range power supply (PSM) in a DIN rail metal housing.

Key tasks include

– Managing and controlling the RTU520 I/O module via the serial I/O bus

– Reading process events from the input modules

– Sending commands to the output modules.

– Communication with the control system and the local HMI system via serial and Ethernet interfaces.

– Communicates with sub-RTUs, IEDs, or multimeter devices via serial and Ethernet interfaces.

– Manages the time base of the RTU540 product line station and synchronizes the I/O modules.

– Handles the dialog between the RTU540 product line and a web browser via LAN and USB interfaces.

– Acquisition of 8 analog input signals (mA or V signals) with a fast scan cycle of 100 ms for 2 inputs – Acquisition of 16 digital input signals with a fast scan cycle of 100 ms for 2 inputs

Acquisition of 16 digital input signals, 1 high-speed counter input (max. 16 kHz)

– 8 output contacts (normally open), 1-pole or 2-pole outputs

The device is equipped with a battery-buffered real-time clock (RTC).

The device is available in two versions:

– R0001: Process voltage 24 … 60 V DC

– R0002: Process voltage 110 … 125 V DC 125 V DC

Search for products

Back to Top
Product has been added to your cart