Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Bently Nevada SCOUT200 series System 1 software

System 1 software,your plantwide solution

Use System 1* to prepare routes, analyze

data, detect long-term trends, set and

detect alarms. Then synchronize data

with your SCOUT handheld using WiFi, file

transfer, cellular network, or a USB cable. But

System 1 doesn’t stop there, it’s the same powerful package

that’s coupled with a broad range of Bently Nevada condition

monitoring and protection products. One source of the truth,

modern and plantwide.

Unlike most products on the market,

the intrinsically safe SCOUT devices

retain the same high performance

and long battery life as their non-rated COMMTEST brethren.

Ten hours of continuous use, while supporting up to: 80

kHz Fmax, 12,800 line spectral resolution, 6-Pack super fast

measurements, 4 channel simultaneous sampling, optional

tachometer. And the firmware updates automatically from

the handheld. Amazing!

Bently Nevada SCOUT200 series Powerful and connected

Powerful and connected

Vibration recordings are viewed and stored on the handheld

device. It runs the Android OS, so you can use it like any

smartphone or tablet to take pictures and video, send

text messages, check email, make phone calls, track your

location, create SOS alerts, and run other enterprise apps. Try

doing all that on an old school data collector!

High performance data acquisition

Unlike most products on the market,

the intrinsically safe SCOUT devices

retain the same high performance

and long battery life as their non-rated COMMTEST brethren.

Ten hours of continuous use, while supporting up to: 80

kHz Fmax, 12,800 line spectral resolution, 6-Pack super fast

measurements, 4 channel simultaneous sampling, optional

tachometer. And the firmware updates automatically from

the handheld. Amazing!

Bently Nevada SCOUT200 series Powerful and connected

Flexible handheld options

Choose from multiple handheld devices

to meet your form factor, screen size, and

hazardous rating needs. Update your

handheld at any time, load the System 1

Collector app onto the new device and get collecting.

So easy to carry

Carry the data acquisition module using a

shoulder strap or a belt clip. Sensors mount onto sensor

keepers. Hold the industrial smartphone or tablet in your

hand, on a belt clip, or on a neck strap. So you can focus on

your job and move safely between machines.

Powerful and connected

Vibration recordings are viewed and stored on the handheld

device. It runs the Android OS, so you can use it like any

smartphone or tablet to take pictures and video, send

text messages, check email, make phone calls, track your

location, create SOS alerts, and run other enterprise apps. Try

doing all that on an old school data collector!

Bently Nevada SCOUT200 series Portable vibration analyzers

Portable vibration analyzers

These portable data collector solutions record the vibration

of industrial machines, to monitor their condition and

diagnose their faults. The Series includes “SCOUT” models

for use in hazardous areas (explosive atmospheres) and

“COMMTEST” models for less stressful environments. There

are 2-channel and 4-channel versions of each, to suit your

data acquisition and analysis needs.

Designed in and for the 21st century

These two-part solutions utilize the power and

connectivity of modern industrial smartphones

and tablets, paired with a small form factor,

rugged data acquisition module. This gives the

best of both worlds, a fast handheld device full of accessories

and communication options, and a simple durable interface

to sensors on your machines.

Bently Nevada Asset Condition Monitoring 3300/03 Keyphasor® TRANSDUCERS

Keyphasor® TRANSDUCERS

The System Monitor receives input from four Keyphasor® transducers through terminals on the

PIM. Two of the Keyphasor® transducers are available to the monitors within the rack. All four of

the Keyphasor® transducers are available to the Dynamic Data Interface (DDI). Buffered

Keyphasor® signals are also available from the coaxial connectors on the front panel. The System

Monitor also provides short-circuit protected Keyphasor® transducer power.

STATIC DATA BUS BUFFER

The System Monitor multiplexes signals from either the DDM or TDM to select static data

from the monitors. The System Monitor buffers the static data signals sent from the

monitor to the DDM or TDM.

The System Monitor supports the following Bently Nevada data interfaces: Dynamic Data

Manager (DDM), Transient Data Manager® (TDM), Serial Data Interface (SDI), Dynamic Data

Interface (DDI) and Transient Data Interface (TDI). The SDI and DDI are options of the System

Monitor and reside within the System Monitor slot of the rack. DDM, TDM and TDI are external

data interfaces which gain access to the rack through the PIM. There is an external version of the

SDI and DDI which connects to the PIM. For more information about these products consult a

Bently Nevada sales representative.

Bently Nevada Asset Condition Monitoring 3300/03 DATA INTERFACE

ALARM SETPOINT ADJUST

The System Monitor has two switches on the front panel that adjust alarm setpoint levels on each

monitor. One switch is for upscale adjustments, and the other switch is for downscale

adjustments.

DATA INTERFACE

The System Monitor supports the following Bently Nevada data interfaces: Dynamic Data

Manager (DDM), Transient Data Manager® (TDM), Serial Data Interface (SDI), Dynamic Data

Interface (DDI) and Transient Data Interface (TDI). The SDI and DDI are options of the System

Monitor and reside within the System Monitor slot of the rack. DDM, TDM and TDI are external

data interfaces which gain access to the rack through the PIM. There is an external version of the

SDI and DDI which connects to the PIM. For more information about these products consult a

Bently Nevada sales representative.

Bently Nevada Asset Condition Monitoring 3300/03 OK RELAY

OK RELAY

The purpose of this relay is to provide a means to annunciate a problem that is detected with any

transducer system connected to the rack. The OK Relay is connected to the OK Circuit of every 

monitor in the rack. The OK Circuit continuously checks the condition of the transducer(s)

associated with that monitor. If the circuit detects a transducer problem, the OK LED on the front

of the affected monitor goes off and a relay drive signal is sent to the OK Relay in the System Monitor.

The OK Relay is located on the System Monitor PIM, is normally energized, and is a single-pole,

double-throw (SPDT) relay. Since it is normally energized, the relay also can be used to

annunciate when mains power to the rack is lost or interrupted. Either a system power-up inhibit

signal from the System Monitor or a not OK signal from any monitor in the rack will cause the OK

Relay to change state.

Bently Nevada Asset Condition Monitoring 3300/03 TRIP MULTIPLY

TRIP MULTIPLY

The most common use of this function is to prevent unwanted monitor alarms during certain

conditions of machine operation. In the operation of some machinery, it is impossible to avoid

some periods of “higher than normal” vibration. Examples include startup and coastdown,

especially if the operating speed is above rotor system balance resonances (“critical speeds”),

structural and other resonances, and changes in machine load or other operating conditions.

The Trip Multiply function causes the monitor alarm setpoints (both Alert and Danger) to increase

by a fixed amount, either two times (2X) or three times (3X), according to the ordering option. Only

those monitors ordered with this option will be affected. The Trip Multiply function is performed in

the System Monitor, but is an ordering option for each monitor. It must be specified at the time of

order placement and be installed at the factory.

Trip Multiply is activated by contact closure on the PIM. A red LED on the System Monitor front

panel indicates that the Trip Multiply function is active.

Bently Nevada Asset Condition Monitoring 3300/03 System Monitor

MONITOR FUNCTIONS

SYSTEM POWER-UP INHIBIT

The System Monitor provides a Power-up Inhibit function. This function allows each monitor to

inhibit its alarms during power-up or whenever a system supply voltage falls below its operating

level. After power-up, the inhibit function remains active for approximately 2 seconds.

RACK INHIBIT

When activated by a external contact closure this function places all monitors in bypass, disables

all alarms, zero scales all outputs, and de-energizes the system OK relay. The connections for this

function are located on the power input module (PIM) at the rear of the rack.

SUPPLY VOLTAGES OK

Seven LEDs located behind the front panel of the System Monitor are ON to indicate the voltage

supplies are functioning. The voltage supplies are +VRH, +VRL, +7.5V, +5V, REF, -7.5V, and -VT.

There is a green LED (SUPPLIES OK) on the front panel of the System Monitor. When this LED is on

all of the voltage supplies are functional.

SYSTEM RESET

The System Monitor provides the ability to cause a System Reset. Closing external contacts

through terminals on the PIM or pressing the RESET switch on the front panel will cause a System

Reset.

Bently Nevada Asset Condition Monitoring 3300 Relay Modules

Description

Relays are important to the integrity of monitoring systems. They provide

external alarm annunciation or input to an automatic shutdown device. You can

order 3300 monitors with quality, built-in relays. Installation requires no external

wiring between relays and rack, and no extra housing to mount the relays. This

facilitates installation and minimizes the chance of errors associated with field wiring.

The 3300 system offers 2 relay module types:

• Dual, with 2 relays per module

• Quad, with 4 relays per module.

For system installations on the machine deck, in hazardous areas, or in areas

with harsh environments, the dual relay module is available with hermeticallysealed relays.

For non-hazardous areas and clean environments such as control

rooms or instrument panels, modules with epoxy-sealed relays are available.

All relay modules include arc suppressors as a standard feature to increase the

life of the contacts by reducing arcing at the switching point.

Search for products

Back to Top
Product has been added to your cart