Grid Solutions Hydran M2-X Key Benefits

Key Benefits

• Small form factor, no moving parts, low maintenance, and support for APM software analytics,

enabling fleet level deployments

• Condition monitoring for a wide range of transformers with mineral insulating oils or ester based

fluids (natural and synthetic)

• Extending beyond DGA monitoring, through the connection of sensors, the Hydran M2-X can monitor

other parameters such as top oil temperature, load current and through the use of IEEE based

mathematical models, can provide further insight on changing transformer conditions

• Providing critical transformer gas behavior data for Asset Performance Management (APM)

strategies, facilitating planning of site intervention and maintenance activities

• Supports a wide range of communication methods and protocols to enable easy and secure

integration with GE’s digital platforms including Perception™ transformer fleet management

software, DS Agile substation HMI, PREDIX™, and other APM software tools, historians and SCADA

systems

Applications

Advanced, flexible and expandable DGA monitoring solution tailored for utility and industrial

transformers.

Easily integrates with Kelman multi-gas DGA devices and the Multilin 845 protection & control

relay to provide continuous synchronization of chemical and electrical measurements for enhanced

transformer monitoring

Grid Solutions Hydran M2-X Enhanced Monitoring

Enhanced Monitoring with Extended Sensor Life

When a transformer’s insulation system is overstressed, the oil and paper undergo chemical

degradation producing both hydro-carbon gases and moisture that dissolve into the insulating oil. This

increased ageing will shorten the transformer’s life, impact its reliability and in some cases can even

lead to catastrophic failures.

The Hydran M2-X is the next generation of the field-proven family of Hydran DGA monitoring solutions.

It provides continuous monitoring of gas and moisture levels to alert users of developing faults and

minimize the risk of unplanned outages. The M2-X builds on GE’s strong domain expertise to deliver an

optimized, low maintenance monitoring device with an extended sensor life.

Advanced, flexible and expandable DGA monitoring solution tailored for utility and industrial

transformers.

Easily integrates with Kelman multi-gas DGA devices and the Multilin 845 protection & control

relay to provide continuous synchronization of chemical and electrical measurements for enhanced

transformer monitoring

Digital Energy Intellix MO150

When an unexpected failure of a critical transformer occurs, the operational and economical impacts

on the utility are substantial. Today, many existing oil-insulated transformers used by electrical utilities

and other industries are approaching the end of their design life and are experiencing significantly

higher probabilities of failures.

Prognastics and Diagnostics

The prognostics and diagnostics software module on the Intellix MO150 is designed to provide

guidance whenever an alarm condition is present. It is intended to provide the first level of awareness

of what the alarm condition is all about, what the alarm condition means and what steps or actions

could be taken to improve the current situation.

The module will provide:

• Diagnostic: Identification of the alarm and/or set of alarm conditions.

• Prognostic: A set of statements that warn the operator about the  possible consequences for the

transformer if the situation is allowed to continue without any remedial action being taken.

• Recommendation: Summarizes the verifications that could be carried out, data that could be

collected to facilitate further actions and specific actions that could improve the current situation.

IBA ibaBM-ENetIP EtherNet/IP-Busmonitor Scope of delivery

Overview of the most important characteristic values:

 TAP interface for sniffer function

 Monitor interface for connecting a network analysis tool

 Data acquisition with ibaPDA

 Simple configuration and measurement via bidirectional FO connection with ibaNet

protocol 32Mbit Flex

 Flexible configuration of sampling rate and data formats with 32Mbit Flex

Scope of delivery

After having unpacked the delivery, please check if it is complete and intact.

The following components are included in delivery:

 ibaBM-ENetIP device

 ibaBM-ENetIP manual

 DVD “iba Software & Manuals”

Designated use

The device is an electrical equipment. It may only be used for the following applications:

 Measurement data acquisition and measurement data analysis

 Automation of industrial plants

 Applications of iba software products (e.g ibaPDA) and iba hardware products

The device may only be used as defined in the “Technical Data” chapter.

IBA ibaBM-ENetIP EtherNet/IP-Busmonitor

The entire communication via the TAP interface is being mirrored to a monitor port and

can be recorded using an external network analysis tool.

On the optical-fiber side, ibaBM-ENetIP works with the ibaNet protocol 32Mbit Flex. With

this protocol, measuring and configuration data are transferred via a bidirectional fiber

optic connection. The sampling rate and the data formats can be configured flexibly.

Overview of the most important characteristic values:

 TAP interface for sniffer function

 Monitor interface for connecting a network analysis tool

 Data acquisition with ibaPDA

 Simple configuration and measurement via bidirectional FO connection with ibaNet

protocol 32Mbit Flex

 Flexible configuration of sampling rate and data formats with 32Mbit Flex

The ibaBM-ENetIP bus monitor can be operated in an EtherNet/IP network without inter

ferences using the TAP interface (Ethernet). The device works as sniffer, i.e. it listens to

the cyclic data exchange of the IO data (implicit messaging) between EtherNet/IP scan

ner (master) and adapters (slaves).

IBA ibaBM-ENetIP EtherNet/IP-Busmonitor Introduction

Introduction

EtherNet/IP (EtherNet Industrial Protocol) is a real-time Ethernet which is mainly used in

automation technology.

The EtherNet/IP bus monitor ibaBM-ENetIP is a device for acquiring the cyclical data

exchange between EtherNet/IP scanner (master) and adapters (slaves). The device can

be integrated into an existing EtherNet/IP network with one or more EtherNet/IP scan

ners (master).

The ibaBM-ENetIP bus monitor can be operated in an EtherNet/IP network without inter

ferences using the TAP interface (Ethernet). The device works as sniffer, i.e. it listens to

the cyclic data exchange of the IO data (implicit messaging) between EtherNet/IP scan

ner (master) and adapters (slaves).

The entire communication via the TAP interface is being mirrored to a monitor port and

can be recorded using an external network analysis tool.

IBA ibaLink-SM-128V-i-2o VMEbus Interface Card Application interface

The following devices are compatible with fiber-optic channel 2 of the SM128V:

 ibaPADU-8-O,

 ibaLink-SM-64-SD16.

 ibaBM-DPM-S-64.

 ibaFOB-4i-S and ibaFOB-io-S (Input),

 ibaFOB-4i-D, ibaFOB-2i-D and ibaFOB-io-D (Input),

 ibaBM-FOX-i-3o and ibaBM-FOX-i-3o-D,

 ibaBM-COL-8i-o

Both fiber-optic output channels (Channel 1 and Channel 2) can be interfaced to indi

vidual ibaCom-PCMCIA-F cards via the X4 and X5 RJ11 sockets. Note that only one

ibaCom-PCMCIA-F card may be used at a time in a Notebook measurement PC.

The VMEbus interface

The SM128V supports a maximum of 64 input channels (a + d) and 128 output chan

nels. The card occupies 256 kByte memory space on the VMEbus. The base VME ad

dress is adjustable using the DIP switch settings as described above.

From the VMEbus viewpoint, WORDs and DWORDs can be read and written in BIG

ENDIAN or LITTLE ENDIAN format. The SM128V-card can accept both formats. The

used format has to be configured with a DIP switch.

Whether the link sends in integer or float format must be defined prior to installing the

SM128V. Use the DIP switch to change this setting for each fiber optic link. Each fiber

optic link must be set independently. Data must then be written to the appropriate regis

ters.

The digital channel values may be written in channel-wise in either a DWORD for each

digital channel (bit 0 of each DWORD) or an 8 byte bit mask. Prior to sending the tele

gram the respective registers are OR’d to determine whether a 0 or 1 is sent in the tel

egram. For this reason, it is important to reset the registers of the unused method.

It’s an asynchronous take-over of data from the VME range into the buffer of the FOB

transmitter. Data coming out of the VME range will be synchronized with the 1 ms clock

of the FOB interface. Thus the take-over time for the data varies between 0 and 1 ms.

IBA ibaLink-SM-128V-i-2o VMEbus Interface Card Application

Application Notes

The optical fiber input/output links operate at 3.3 Mbps.

The following components are compatible with fiber-optic channel 1 of the SM128V:

 ibaLink-SM-64-io (but mixed cascade of ibaLink-SM-64-io and SM128V is not supported),

 ibaLink-SM-64-SD16.

 ibaBM-DPM-S-64.

 ibaPADU-8. ibaPADU-8-I, ibaPADU-8-O,

 ibaFOB-4io-S and ibaFOB-io-S,

 ibaFOB-4io-D, ibaFOB-2io-D and ibaFOB-io-D,

 ibaBM-FOX-i-3o and ibaBM-FOX-i-3o-D,

 ibaBM-COL-8i-o, ibaBM-DIS-i-8o

The following operation modes are supported on channel 1:

 I/O operation; up to eight devices connected to the fiber-optic input (Rx) and up to

eight devices connected to the fiber-optic output (Tx)

 Cascade operation with daisy-chain of up to eight SM128V cards

 Addressing of input and output data in steps of eight signals.

Channel 2 provides 64 channels for transmission only.

IC693CMM321 Ethernet Interface Module

The Ethernet Interface module (IC693CMM321) provides an interface that allows you to attach the

Series 90-30 PLC to an Ethernet LAN via an external transceiver and AAUI cable, and to

communicate with hosts and other control devices on the network.

The Ethernet Interface for the Series 90-30 PLC has client/server capability.  As a client it can

initiate communications with other PLCs containing Ethernet Interfaces.  This is done from the

ladder program using the COMMREQ Function Block.  As a server it responds only to requests

from other devices such as a Host computer running a Host Communications Toolkit application or

another Series 90-30 PLC acting as a client.

The Ethernet Interface allows you to:

Directly attach your PLC to an Ethernet network

Initiate transfer of data to the PLC from another device

Communicate simultaneously to multiple devices with up to 16 server connections

Interface with other GE Fanuc devices, as well as with devices from other vendors

Communicate from a Host computer (or other control device)

Diagnose and maintain your system using diagnostic and station management tools

The Ethernet Interface does not support the Series 90-30/20/Micro Hand-Held Programmer. 

Either one or two Ethernet Interface modules can be installed in any Series 90-30 baseplate.

The Ethernet Interface connects to an Ethernet network through an external SQE enabled

transceiver (GE Fanuc catalog no. IC649AEA102 or IC649AEA103 or equivalent.

See AppendixJ).  The following figure shows the layout of the Ethernet Interface.

8751-CA-NS ELFD Controller Carrier

The ELFD Controller Carrier provides a mounting platform for up to two SafetyNet Controllers (8851-LC-MT) .

It can also accommodate a Power Supply Monitor module (8410-NS-PS)

which can monitor the health of up to two 8913-PS-AC,

four 8914-PS-AC power supplies and the 12V supply to Intrinsically Safe Modules (when these are used) .

For each Controller there is a serial port connector and a manually operated ““Change State” button .

The Carrier also provides terminals that are used when earth leakage fault detection is required.

Search for products

Back to Top
Product has been added to your cart