The SLC Servo Module operates in two modes:

• Configuration 

• Command 

When operating in the configuration or the command mode, the status 

of the module is reported to the SLC processor.

Configuration Mode Operation

You can enter configuration mode only if the system is in Estop. In the 

SLC Servo Module, you configure the SLC Servo Module by using M 

files containing data provided by the SLC 5/03 (or versions listed 

above) processors. All configuration parameters are internal to the SLC 

Servo Module and stored in non-battery backed RAM.

In configuration mode, you select the proper setup configuration to 

match the servo drive and motor without setting switches and without 

special software. If you do not set up your own configuration, the 

configuration is set to the default setting.