Connection Solutions

Several accessories are available with 460 volt 1326 cables. This

section highlights the most common application used with each

accessory, including:

• Right-angle connection.

• CE-compliant in-line connection.

• Remote in-line connection.

• Harsh environment connection.

• Double-ended bulkhead in-line connection.

Right-Angle Connection

This solution provides a low-profile right-angle connection at the motor

Linear-flex is defined as flex in one direction. The flex-rated cable is

not rated for twist-flex, which is flex in two directions. Power track

(linear-flex) cabling must not be used in twist applications.

Standard Allen-Bradley cables—1326-CCU-xxx for commutation and

1326-CPB1-xxx or 1326-CPC1-xxx for power—are tray-rated

(stationary) and should only be used for one-time flex applications.

• Power track cabling is required for applications where dynamic

linear flexing occurs. Use the following cables for these applications:

• 1326-CCUT-xxx (commutation for all motors)

• 1326-CPB1T-xxx (power for 1326AS-B3xxx and 1326AS-B4xxx motors)

• 1326-CPC1T-xxx (power for 1326AS-B6xxx and 1326AS-B8xxx motors)