Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Emerson Smart Switch Commissioning

Smart Switch Commissioning

Commissioning is done from a DeltaV workstation after the

switch is placed in service. Commissioning the switches after

they are installed creates the interface between DeltaV and

the switch that gains the full benefit of using the Smart Switch.

Commissioning allows the advanced switch setup parameters in

the switch to be preconfigured so they only have to be entered

once for the system. These parameters only have to be changed

if the default settings need to be modified.

Once the commissioning process assigns a network address

to the switch it will automatically begin reporting PlantWeb

alerts to the workstations. It also allows the Network Device

Command Center access to network diagnostics and the one

click lockdown security application. Integration into the DeltaV

system eliminates the pre-installation configuration and gets your

system back to full strength as quickly as possible.

Emerson DeltaV Plug-and-Play Installation

DeltaV Plug-and-Play Installation

The DeltaV switches are easy to install in your DeltaV

network. Since they come preconfigured from the factory,

installation is as simple as mounting the unit, connecting the

communications cables, and powering up the unit. The switch

is configured to begin communications on power up — no

additional setup is required for the switching function to work

properly. This immediately returns the system to full redundancy

capability as quickly as possible with no time wasted configuring

the switch prior to installation.

Plug-and-play installation. Smart Switches are configured

with DeltaV-compatible settings so that they can be installed

into a compatible DeltaV network right out of the box. They

require no user configuration to fully support DeltaV network

communications. There is no user access to make changes to

this default switching configuration so you never have to worry

about a misconfigured switch impacting network performance.

Plug and play requires any existing switches or network devices

to be configured to communicate in 100/1000 full duplex or to

auto-negotiate. See the compatibility sections in this document

for details.

Emerson DeltaV Network Device Command Center

DeltaV Network Device Command Center

The DeltaV Network Device Command Center is a DeltaV

application that provides full integration of the DeltaV Smart

Switches into the DeltaV and the DeltaV 2.5 networks. The

Command Center is used to perform switch commissioning

to create the communication between the DeltaV network

and the switch management application. The Network

Device Command Center provides access to the switch and

network diagnostics, device alert details, and port lockdown

applications. The management application provides a

centralized application to commission, diagnose, troubleshoot,

and secure the DeltaV Smart Switches. The Command Center

can be viewed by any DeltaV user.

The ability to commission and lock switches is limited to

the Can Configure, Can Calibrate, and Can Download user

privileges. Starting in DeltaV v13.3 the DeltaV Smart Switch can

be installed in the DeltaV 2.5 network or other DeltaV networks

external to the DeltaV control network. For the DeltaV Smart

Switch to be installed in a network the switch must be connected

to a DeltaV workstation (for example, Professional Plus) running

control modules.

Emerson Completely Managed by DeltaV

Benefits

Completely Managed by DeltaV. Power up the switch and it is

automatically discovered by the DeltaV switch commissioning

application in the Network Device Command Center (formerly

the Smart Switch Command Center). The network address

is automatically assigned by DeltaV DCS or by the user when

installed in the DeltaV 2.5 network (new in DeltaV v13.3).

Just provide a switch name, description, and select a few setup

parameters and the switch begins reporting. No more serial

connections are required to configure switches.

Network alerts and diagnostics automatically reported

to DeltaV workstations. Operators and maintenance

stations will automatically receive device alerts indicating

network communications irregularities. The DeltaV

Network Device Command Center application provides

the interface to diagnose and troubleshoot network problems.

All built-in without the need for third party applications for

network monitoring.

Emerson Auto lockdown prevents unauthorized network connections

Auto lockdown prevents unauthorized network

connections. Disabling unused network connections is a

security “best practice” and helps you comply with plant

security policies. With the one-click lockdown capability built

into the switch, you can automatically lock all unused network

ports in the system with a single button click in the DeltaV

Network Device Command Center application. Easy to secure the

network from intrusions.

Full range of switch hardware configurations. DeltaV

network switches are available in a variety of hardware

solutions. From a 24-port rack-mounted unit to both fixed

port and modular field-mounted switches, the DeltaV network

switch will meet a wide variety of network requirements.

The broad line of DeltaV Smart Switches are all you need to

implement a complete DeltaV control network.

Fully supported by Emerson. As Emerson products, these

DeltaV Network Switches are completely supported by Emerson

when used within the DeltaV network. You receive full technical

support from our Global Service Center, warranty support,

product support, and education—all from Emerson.

Emerson DeltaV™ Network “Smart” switches

Introduction

The DeltaV™ Network “Smart” switches are the next generation

in the use of commercial off-the-shelf (COTS) components

in control systems. Called “purpose-built” commercial

components, these switches combine the lower cost of off-the

shelf components with DeltaV specific software and features

to make them more integrated and plug-and-play in the

DeltaV Area Control Network (ACN) and other DeltaV networks

external to the ACN.

DeltaV Smart Switches require no configuration to function in

the DeltaV networks. Accessing the advanced features takes

only minor configuration that is easy to perform using the

DeltaV Network Device Command Center and secured so you

can’t incorrectly configure any switching functions that impact

the performance of the DeltaV system.

Emerson DeltaV Distributed Control System

•  Completely managed by DeltaV systems

•  Network alerts and diagnostics automatically

reported to DeltaV workstations

•  Can be installed on the network between the

DeltaV workstations and the Emerson Smart

Firewall (DeltaV 2.5 network)

•  Plug-and-play installation

•  Auto security lockdown

•  A full line of Industrial Rated Fanless Switches

•  Fully supported by Emerson

DeltaV Smart Switches require no configuration to function in

the DeltaV networks. Accessing the advanced features takes

only minor configuration that is easy to perform using the

DeltaV Network Device Command Center and secured so you

can’t incorrectly configure any switching functions that impact

the performance of the DeltaV system.

This purpose-built switch allows the DeltaV system to provide

an auto port lockdown advanced security feature that is easy for

a control system user to implement: an increasingly important

product feature in today’s hostile environment.

ABB Cyberex® SuperSwitch®GT Standards conformance

Standards conformance

The SuperSwitch®GT shall operate in conformance

with the following applicable standards:

• IEEE 1547 – standard for interconnecting

distributed resources with electric power systems)

• ITIC

Order fulfillment

Prior to receipt of the confirmed order, the approval

drawings set will contain the following information

• Physical arrangement and outline dimensions of equipment and equipment base details

• Weight of each shipping section

• Location in plan and elevation of incoming and outgoing terminals

• Space available for entrance of conduits

• Location in plan and elevation of all ground terminals

• Complete list and rating of all equipment devices to be furnished

• Single line diagram

• Complete interconnection diagrams for all internal and field wiring

• Complete details showing locations of all bus with bolting details

• Complete details for enclosures showing bolting details between sections

• Grid tie switch operating system description

• List of recommended spare parts

SuperSwitch®GT can be customized to meet various

application needs. Therefore, we require the

following with a request for quote:

• Basic specifications and one line

• Application and components involved such as wind,solar, DG etc.

• Site specifics

• Any special coordination or testing needs

ABB The SuperSwitch®GT offers the following GUI controls

Analog data provided

• kW

• kVAR

• PF

• RMS phase voltages

• RMS phase currents

• Symmetrical components

Digital data provided

• Switch open

• Switch closed

• Switch bypassed

• Auto mode selected

• Manual mode selected

The SuperSwitch®GT offers the following GUI controls

• Local – will connect and reconnect when conditions are within limits.

• Off – is disconnected and semiconductors are de-energized.

• Remote – accepts “connect” and “disconnect”

commands from an external control system. If the

connect command is given it will connect and

disconnect when conditions are within limits of

the SuperSwitch®GT internal controls.

ABB Cyberex® SuperSwitch®GT Technical specifications

Technical specifications

General

• 200–1200A

• 480 VAC, 3-phase, 3 or 4-wire (neutral not switched), 60Hz

• Exceeds ITIC requirements by disconnecting

from failing utility in under 20ms

• Load protection with smooth, instantaneous

transfer between micro and utility grid

protection events, IEEE 1547 events, and power quality events.

• Automatic sensing and control automatic

separation of microgrid and utility grid during

system problem and reconnection back to the

utility grid when the utility system is normal

• Offers synchronism check

• Based on silicon controlled rectifier (SCR) technology

• Offers necessary series protection to clear any

internal faults caused by component failures

• Normal rating is 220% of the system rated

voltage per IEEE 1547 Section 4.1.8.3.

• Communications capabilities through relays and modbus RTU (RS485) or modbus TCP/IP

• Easy interface to a SCADA system via modbus RTU (RS485) or modbus TCP/IP

• Optional NEMA 3R enclosure

Search for products

Back to Top
Product has been added to your cart