Fanuc Field Control Environmental Specifications

Field Control Environmental Specifications

Vibration

Noise

Temperature

Humidity

Modules perform well where vibration is a factor. Modules are installed

on a panel-mounted DIN rail using the clamp supplied, and with the

panel-mounting feet secured. For information about vibration

standards, please see the Conformance to Standards document (GFK-1179).

Modules are resistant to noise levels found in most industrial applications

when installed according to accepted practices, including proper separation

of wiring by voltage and power level. Modules must be installed on a

conductive (unpainted) DIN rail. The DIN rail is an integral part of the

grounding system.

Modules are tested to the specifications listed in the Conformance to

Standards document (GFK-1179).

Modules operate reliably in ambient air temperatures from 0C (32F)

up to 55C (131F).

Storage temperatures are ±40C (±40F) to +85C (185F).

5% to 95%, non-condensing.

For detailed installation information, please see:

Chapter 2 of this manual. It describes installation and wiring for the Bus Interface

Unit module and terminal block.

Chapter 2 of the Field Control I/O Modules User’s Manual. It summarizes installation

instructions for modules and terminal blocks.  Detailed installation instructions are

also packed with individual Field Control modules.

The individual module datasheets included in the Field Control I/O Modules User’s

Manual, which provide specific module wiring information.

GE Fanuc Profibus Bus Interface Unit

Locations for Field Control

The Profibus Bus Interface Unit and Field Control I/O modules can be located on

equipment, in junction boxes, inside panels, behind operator stations, and in other

locations where space is limited. The area should be clean, free of airborne contaminants,

and provide adequate cooling. Field Control modules can be installed in NEMA

enclosures. The enclosure can be as little as 4 inches (10.16 cm) deep. A 35mm x 7.5mm

DIN rail is required.

The Bus Interface Unit Terminal Block and up to four I/O Terminal Blocks are grouped

together  using the connection cables provided. All of the I/O Terminal Blocks in a group

must be connected either before or after the Bus Interface Unit. A Bus Interface Unit

may not be connected between I/O Terminal Blocks.This manual describes the installation

requirements for programmable control products used in industrial environments,

specifically, in situations where compliance to standards or directives from the

Federal Communications Commission, the Canadian Department of

Communications, or the European Union is necessary. The information in this

manual is applicable for GE Fanuc Series 90-70 and Series 90-30 programmable

controller products, Genius I/O products,  and Field Control Distributed I/O and Control products.

Fanuc Profibus Bus Interface Unit

Profibus Bus Interface Unit

The Profibus Bus Interface Unit interfaces Field Control I/O modules to a Profibus I/O bus.

The intelligent processing capabilities of the Profibus Bus Interface Unit allow the

configuration of features such as fault reporting, selectable input and output defaults, analog

scaling and analog range selection for the modules in the station. In addition, the Profibus

Bus Interface Unit performs diagnostic checks on itself and its I/O modules, and relays

diagnostic information to the host (if configured for fault reporting) and to a Hand-held

Programmer.

The Bus Interface Unit mounts on a Bus Interface Unit Terminal Block. The Bus Interface

Unit can be removed and replaced if necessary without removing the wiring or

reconfiguring the I/O station.

Bus Interface Unit Terminal Block

The Bus Interface Unit Terminal Block provides connections for power wiring and single

or dual communications cables. The Bus Interface Unit Terminal Block stores the

configuration parameters selected for the station.

Fanuc I/O Terminal Blocks and Auxiliary I/O Terminal Blocks

I/O Terminal Blocks and Auxiliary I/O Terminal Blocks

An I/O Terminal Block provides mounting, electrical, and field wiring connections.  Each half

of the I/O Terminal Block can be mechanically keyed to accept only an I/O module of a

specific type. Auxiliary I/O Terminal Blocks can be easily attached to an I/O Terminal Block.

They provide the extra connections needed for analog and high-density discrete modules.

For more information, please refer to:

Chapter 2: Installation, which explains wiring to the Bus Interface Unit, and explains

how to install the Bus Interface Unit module on the Field Terminal Block.

Chapter 5: Operation, which explains how the Profibus Bus Interface Unit services I/O.

The Field Control I/O Modules User’s Manual, which describes I/O modules and I/O

Terminal Blocks. This manual also explains module installation and field wiring.

Bus Interface Unit Terminal Block

The Bus Interface Unit Terminal Block provides connections for power wiring and single

or dual communications cables. The Bus Interface Unit Terminal Block stores the

configuration parameters selected for the station.

I/O Modules

Field Control I/O Modules are available in many types to suit a wide range of application

needs. Modules can be installed and removed without disturbing field wiring. One or

two I/O modules may be mounted on an I/O Terminal Block.

Fanuc Field Control modules Features

Field Control Features

Features and benefits of Field Control include:

wiring savings

more up time

easy installation and maintenance

spare parts savings

low cost

feature flexibility

open architecture / adaptable to a variety of networks

distributed I/O

small, compact I/O modules with generic terminal wiring bases

DIN rail mounted

Field Control Modules

There are three basic types of Field Control modules:

Bus Interface Unit. The illustration below shows a Profibus Bus Interface Unit.

I/O modules

Terminal Blocks:

Bus Interface Unit Terminal Block.

I/O Terminal Blocks, each of which accommodates two I/O modules.

Auxiliary Terminal Blocks. These optional terminal strips can be connected to the

side of an I/O Terminal Block if extra common terminals are needed.

Fanuc Field Control is a family of highly-modular distributed I/O

Overview

Field Control is a family of highly-modular distributed I/O and control products. They

are suitable for use in a wide range of host architectures.

The heart of the Field Control system is the Bus Interface Unit. The Bus Interface Unit

provides intelligent processing, I/O scanning, and feature configuration for a group of up to

eight I/O modules. Together, the Bus Interface Unit and its modules make up a Field Control

station.

The Bus Interface Unit and I/O modules are enclosed in sturdy, compact aluminum

housings. Bus Interface Unit and I/O modules bolt securely to separate Terminal Blocks,

which provide all field wiring terminals. The I/O Terminal blocks are generic and allow

different I/O module types to be mounted on the same base.  I/O Terminal Blocks are

available with box-type terminals, barrier-type terminals, or wire-to-board connectors.

All Terminal Blocks must be mounted on a DIN rail. The DIN rail, which serves as an

integral part of the grounding system, can also be mounted on a panel.

ABB RVT Programmable protection thresholds

Programmable protection thresholds

Programmable thresholds allow you to protect the

capacitor bank against over- and under-voltage, over

temperature and excessive harmonic distortions.

Network information and capacitor bank monitoring

The RVT computes and displays network and capacitor

bank information such as voltage, current, harmonics

spectra and much more.

Multi-language support

The RVT allows you to choose its working language

between English, French, German, Spanish and Chinese.

Digital inputs

Two digital inputs can be used for day/night power factor and

external alarm respectively.

Two alarm relay outputs and fan / warning output

RVT has two alarm relay outputs (NO and NC) and a FAN/

Warning relay output.

ABB RVT High ambient temperature rating

High ambient temperature rating

The RVT is suitable for harsh ambient environments thanks to

its maximum ambient temperature rating of 70°C.

Multi-voltage and multi-frequency

The RVT may be connected to network voltages in the range

100-460Vac, 50/60Hz. RVT’s measurement voltage is up to

690Vac without connecting any additional PT.

Works with 5A and 1A CT’s

Both 5A and 1A CT’s may be connected to the RVT.

Digital inputs

Two digital inputs can be used for day/night power factor and

external alarm respectively.

Two alarm relay outputs and fan / warning output

RVT has two alarm relay outputs (NO and NC) and a FAN/

Warning relay output.

ABB RVT is also a MV and HV bank controller

Other powerful features

RVT is also a MV and HV bank controller

By connecting a PT to the RVT voltage measurements inputs,

and setting the proper [V scaling] according to the PT ratio,

the RVT is able to control a MV or HV capacitor bank just like

a LV capacitor bank.

Easy commissioning

The fully automatic set-up of the RVT parameters totally eases

the bank commissioning process.

Menu navigation

The clever organization of menus and sub-menus ensures

menu navigation easy and intuitive.

Guided navigation and programming

Online help information guides you step by step in the menu

navigation and RVT programming.

Communication

RVT has versatile communication interfaces: in addition to

Ethernet 10/100BASE-T and USB2.0. the RVT supports

RS485 connection as well. All parameters settings and

measurements are accessible remotely.

Fully automatic set-up

C/k (sensitivity), active outputs, switching sequence and

phase shift can be automatically set-up.

ABB Power Factor Controller RVT

Touch Screen

3.5 inch colorful QVGA touch screen eases your parameter

settings.

Ethernet connection

With ABB PQ Link software, you may easily plug an RJ

45 to RVT and communicate with the controller through a

10/100BASE-T interface anywhere in the world.

USB connection

RVT supports USB2.0 connection; which makes it possible to

connect to a computer via a widely used USB cable to access

all RVT parameters.

Up to 8 Temperature alarm outputs

RVT can monitor 8 hot spots in your bank through eight

daisy-chain connected temperature probes.

Real time clock

RVT real time clock tracks and logs date and moment of each

alarm and event.

Hardware and software lock

Both hardware and software locks are equipped in the RVT

for bank setting protections from any unauthorized access.