Welcome to the official website of CNIACS Automation Technology Co., Ltd!

ABB AMVAC Indoor Vacuum Circuit Breaker

The next generation in ANSI medium voltage vacuum circuit breaker technology.

The AMVAC is the next generation of ANSI medium voltage vacuum circuit breaker, 

utilizing magnetic actuation technology to provide a more reliable and longer lasting solution to the industry. 

This is made possible by the simplicity of the magnetic actuator design features such as one moving part and built-in safety features.

Benefits

•Simple open and close coils, an electronic controller and capacitors for energy storage

•Requires the least maintenance of all medium voltage vacuum circuit breaker designs on the market today

•High number of operations between breaker servicing

•Increases safety by reducing personnel time in front of switchgear lineups

Features

•Rated at up to 15 kV, 3000 A, 50 kA and 27 kV, 2000 A, 25 kA

•Low-maintenance magnetic actuator mechanism and electronic controller

•Standard five-year warranty

•Fixed and withdrawable versions with front operating mechanism

•Stored energy operating mechanism with mechanical anti-pumping device supplied as standard

•Remote motorized racking options are available

Although many refinements have been made throughout the 80-90

year history of the medium voltage circuit breaker, there have

been only four generations of circuit breaker design. Early circuit

breakers were spring charged units with separate close and trip

springs. These units were used for older air-magnetic breakers.

The second generation used the same mechanism modified for

use with a vacuum bottle. 

ABB ADVAC® G Vacuum generator circuit breaker Key features

Key features

•Ratings up to …15 kV, 4.000 A, …63 kA

•Fully compatible to power distribution switchgear dimensions/interfaces

•Completely type tested in accordance to the latest IEEE/IEC 62271-37-013 standard

•Remote motorized racking options are available

Protect assets

•Compliant with the latest global standard – IEEE as well as IEC

•Generator circuit breaker suitable for demanding conditions, including out-of-phase condition and

island mode

•Safety enhanced due to completely tested solution

for DC-component up to 130%; no need to add any

time delay

Optimize investment

•Choose ratings from 40/25 kA @ 15 kV to

63/50 kA @ 15 kV

•Take advantage of the same compact switchgear

setup used in power distribution systems

ABB ADVAC® G Vacuum generator circuit breaker

Small footprint, full protection for Generator Applications

The ADVAC® G is tested to meet the most stringent IEEE and IEC requirements

for generator applications as per IEEE C37.013 and the new revision IEC/IEEE 62271-37-013. the only standards for GCB.

Key benefits

•Safety and protection of personnel and assets in all service modes

including out-of-phase condition and up to 130% direct current component

•Accelerate projects with easy generator circuit breaker integration and dedicated application support

•Optimum interface with all different ratings available

•Accelerate projects with outstanding technical support from the field application engineering team

Maximize output

•Experience easy installation/integration of

ADVAC G40. thanks to its equivalent interfaces

and dimensions like ADVAC

•Accelerate projects with outstanding technical

support from the field application engineering team

ABB ADVAC 38 Vacuum Circuit Breaker Applications

Optimize investment

•Optimized design with compact, single-sized compartment for all ratings

•Lowest power consumption accessories for reduced battery bank systems

Reduce maintenance costs

•Class M2. 10.000 mechanical operations

•Globally proven EL operating mechanism and racking truck are shared for all ADVAC circuit breakers, requiring no adjustment or measurement

•Reduced vacuum interrupter wear design requires no visible or mechanical measurements

•Maintenance-free embedded pole design helps protect vacuum interrupters from contamination, moisture, and damage and helps improve tracking resistance

Applications

•Utilities

•Renewables

•Data Centers

•Industrial

Segments/Channels

•Panel builders

•OEMs

•End users

ABB ADVAC 38 Vacuum Circuit Breaker

ADVAC 38KV 3000A 40KA

Complete portfolio and rating extension

ABB offers its new 38 kV class medium voltage vacuum circuit breaker with 

spring mechanism type EL (used in products like Emax 2 and VD4) and new vacuum 

interrupter technology up to 40.5 kV, 3000A,  40 kA, 190 kV BIL with 1000 A C2 back to back capacitive switching available.

Help keep personnel safe

•ADVAC38 is the lightest weight 38 kV circuit breaker in the industry, helping increase personnel safety

•Roll-on-floor (ROF) caster design offers ease of use

•Remote motorized racking options are available

Save floor space

•Space-saving compact design

•Two-high stacking compatible

Protect assets: Type tested according to:

•C37.09-2018

•C37.54-2002

•C37.55-2020

•C37.20.2-2015 Annex C for partial discharge testing

ABB ANSI indoor vacuum circuit breaker ADVAC

A unique modular design allows for quick and safe service for motors, coils and key components

The ADVAC series is a complete line of ANSI-rated vacuum circuit breakers 

with a spring-charged mechanism offering power distribution system customers 

the advantages of the latest technology with a modular design that is easily maintainable.

Key benefits

ABB EL spring mechanism used on various ANSI and IEC breakers to provide up to 20.000 

mechanical operations in a compact, modular design that is readily accessible and easily maintained to reduce downtime

Modular Smart Coil assembly used in multiple ABB breakers provides close, 

open and undervoltage actuation in one simple assembly

The motor assembly can be replaced by removing a single screw, thereby reducing downtime

Vacuum interrupters completely embedded in a solid insulation material provide superior protection against dust, 

dirt and condensation, and are less susceptible to failure due to contamination, tracking or partial discharge

Key features

5kV, 8kV, 15 kV, and 38kV heavy duty breaker rated at 1200A, 2000A, 3000A 

and 4000A FAC continuous current and 25 kA thru 63 kA interrupting current

Safety features include standard built-in mechanical anti-pumping device, KIRK key, 

padlocking, push-button cover provisions and closed-door racking

The racking mechanism (truck) is integrated into the breaker and designed to 180 ft2lb torque 

rating to provide increased reliability and reduced maintenance costs

ABB ADVAC Indoor Vacuum Circuit Breaker Benefits

Benefits

ABB EL spring mechanism used on various ANSI and IEC breakers to 

provide up to 20.000 mechanical operations in a compact,

modular design that is readily accessible and easily maintained to reduce downtime

Modular Smart Coil assembly used in multiple ABB breakers provides close,

open and undervoltage actuation in one simple assembly

The motor assembly can be replaced by removing a single screw, thereby reducing downtime

Vacuum interrupters completely embedded in a solid insulation material provide

superior protection against dust, dirt and condensation,

and are less susceptible to failure due to contamination, tracking or partial.

ABB ADVAC Indoor Vacuum Circuit Breaker

The ADVAC series is a complete line of ANSI-rated vacuum circuit breakers with 

a spring-charged mechanism offering power distribution system customers the 

advantages of the latest technology with a modular design that is easily maintainable.

Features

5 to 15 kV heavy duty breaker rated at 1200 A to 3000 A continuous current and 25 kA to 63 kA interrupting current

Safety features include standard built-in mechanical anti-pumping device, 

KIRK key, padlocking, push-button cover provisions and closed-door racking

The racking mechanism (truck) is integrated into the breaker and designed to 

180 ft2lb torque rating to provide increased reliability and reduced maintenance costs

Remote motorized racking options are available.

A-B 1746-N3 SLC 500™ 32-Point I/O Module Connector Kit Crimp Contacts

(1) To maintain group isolation provided by 32-point I/O modules, use a 1492 terminal block that provides group isolation. 

Consult 1492 documentation or your Allen-Bradley Sales Office for additional information.

(2) Maximum user cable length is dependent on how much voltage drop (current x (ohms/ft.) x (feet)) the user’s system can 

tolerate. The user’s system should take into account the minimum turn-on voltage required by external loads connected to 

the 32-point output modules and all of the voltage drops associated with wiring to and from the load, terminal blocks, 

power sources and the module itself.

Assembly Procedure for Crimp Contacts

The following details the assembly procedure for the crimp type contacts.

1. Strip the wire insulation as shown in Figure 1.

2. Insert the wire up to the wire stop as shown in Figure 2.

3. Crimp with DDK crimp tool 357J-5538. Equivalent Amp part numbers are: 

pin – 87666-2, connector – 102387-9, and crimp tool – 90418-1.

If a crimp tool is not available, used the following crimping procedure:

a. Crimp the wire barrel around the wire using a small needle nose pliers.

b. Crimp the insulation barrel around the wire insulation using a small 

needle nose pliers.

c. Solder wire and wire barrel together.

4. After completing above assembly, insert the cable into the socket housing as 

shown in Figures 3 and 4. Check to make sure that the tang, shown as “A” in 

Figure 4, is properly latched by gently pulling on the wire.

A-B 1746-N3 SLC 500™ 32-Point I/O Module Connector Kit

Overview

The 1746-N3 Connector Kit is used to terminate a cable which connects field I/O 

devices to SLC 500 32-point I/O modules. The kit contains a keyed 40-pin socket 

header with 45 socket crimp type contacts.

The N3 connector is compatible with 32-point I/O modules, catalog numbers 

1746-IB32, -IV32, -OB32, -OB32E -OV32 and Allen-Bradley 1492-IFM40 terminal 

blocks (see illustration). When the 1746-N3 is used to terminate the I/O cable at the 

1492-IFM40 end, it should be wired in a straight-through manner (i.e. pin 1 to pin 1, 

pin 2 to pin 2, etc.). For additional instructions, refer to the wiring instructions 

provided with your 32-point I/O module.

Use 24 AWG wire with the 1746-N3. Maximum wire length to the user terminal 

block is 10 meters for inputs and 3 meters for outputs with 7-strand, 24 AWG wire.

Search for products

Back to Top
Product has been added to your cart