Welcome to the official website of CNIACS Automation Technology Co., Ltd!

A-B 1326 Cables for 460V AC Servo Motors Connection Solutions

Connection Solutions

Several accessories are available with 460 volt 1326 cables. This

section highlights the most common application used with each

accessory, including:

• Right-angle connection.

• CE-compliant in-line connection.

• Remote in-line connection.

• Harsh environment connection.

• Double-ended bulkhead in-line connection.

Right-Angle Connection

This solution provides a low-profile right-angle connection at the motor

Linear-flex is defined as flex in one direction. The flex-rated cable is

not rated for twist-flex, which is flex in two directions. Power track

(linear-flex) cabling must not be used in twist applications.

Standard Allen-Bradley cables—1326-CCU-xxx for commutation and

1326-CPB1-xxx or 1326-CPC1-xxx for power—are tray-rated

(stationary) and should only be used for one-time flex applications.

• Power track cabling is required for applications where dynamic

linear flexing occurs. Use the following cables for these applications:

• 1326-CCUT-xxx (commutation for all motors)

• 1326-CPB1T-xxx (power for 1326AS-B3xxx and 1326AS-B4xxx motors)

• 1326-CPC1T-xxx (power for 1326AS-B6xxx and 1326AS-B8xxx motors)

A-B 1326 Cables for 460V AC Servo Motors

Servomotor Cable

Series B Power cables (catalog number 1326-CPB1 and 1326-CPC1)

and commutation cables (catalog number 1326-CCU and 1326-

CECU) are available in lengths up to 90 m (295 ft) for standard, one

time flex applications. (PLTC 90° C 300V, AWM 90° C 300V for

1326-CCU and 1326-CECU, type TC 90° C 600V for 1326-CPB1

and 1326-CPC1.) Each cable features:

• UL Listed (file #E88699) cable assemblies.

• A braided cable shield for superior electromagnetic noise immunity.

• Molded push/pull connectors at the motor end for easy installation and maintenance.

Cable systems for 1394 Motion Control System:

• Standard single-connector cables.

• Right-angle connector cables.

• In-line system that uses bulkhead and double-ended cables.

• Harsh environment cables.

• High-resolution feedback cables.

A-B 1326AB High Performance AC Servomotors


Servomotor Options

Options available for the 1326AB include (option code designation or

catalog number in parenthesis):

• Integral spring-set holding brakes with 90V DC coils (-A4, -A5, -A7) or

24V DC coils (-K4, -K5, -K7).

• Brake Power Supply (1326-MOD-BPS) converts 115V AC to the

voltage needed for 90V DC brakes (-A4, -A5 and -A7).

• Shaft Oil Seal kits (1326AB-MOD-SSV-xx) for field installation of

Viton shaft seals. Motor disassembly is not required.

• NEMA Inch (-11) or IEC metric flange mount (-21) with metric shafts.

• Resolver Feedback Packages (1326AB-MOD-Vxxxx) provide 4.25”

(108 mm) transducers which offer absolute/vernier or single brushless

resolver feedback for use with Allen-Bradley 8600GP, IMC rack and S Class motion controllers.

• Junction Box Kit (1326AB-MOD-RJxx) available with axially mounted

connectors. Connector version allows the motor connectors to be

brought out axially to the motor (rather than radially) without further wiring.

• Secondary Feedback Mounting Kits (1326AB-MOD-Mx) for field

installation of an Allen-Bradley Encoder (845H) or resolver. Using a

1326AB motor with a 1391B-ES (or 1391-DES) with A Quad B

feedback (up to 2048 ppr) eliminates the need for encoder mounting.

• Blower Cooling Kit (1326AB-MOD-G3, G4) provides air over cooling

for up to 35% more torque output on most 1326AB “C” frame motors.

The kit can be field mounted on the rear of 1326AB-Cxx motors (in

cluding motors with brakes). For motors using secondary motor

mounted feedback (1326AB-MOD-M60), use option “G4.”

• Cables for power (1326-CPxx . .) and feedback (1326-CFx . . – com

mutation, 1326-CEx . . – encoders) are available in lengths up to 100 ft

.(30 m) for standard and high flex applications Power (1326ES-CPxx . .)

and commutation (1326ES-CFx . .) cables over 100 ft. (30 m), up to 300

ft. (90 m) are available when using 1391B-ES or 1391-DES drives only.

A-B 1326AB High Performance AC Servomotors

Basic Servomotor Description

The 1326AB Servomotors are a family of high performance, three-phase,

brushless AC synchronous motors designed by Allen-Bradley to meet the

stringent requirements of servo system applications. This series of standard

AC servomotors can be used with 1391 AC Servo Controllers. The perfor

mance parameters of these motors with selected amplifiers are listed on

page 8. The typical speed-torque curves (see page 9) depict the opera

tional envelope of these motor and controller combinations.

Each motor has the following standard features:

• Permanent magnet rotor for increased servo response.

• Three-phase sinusoidal wound stator field for direct transfer of heat to

ambient, and smooth operation at low speeds.

• Brushless resolver supplies position, commutation & velocity feedback

information. This also provides durability in harsh environments by not

having on-board electronics in the motor. 1391 A Quad B (optional)

encoder output (up to 2048 ppr) is generated via resolver feedback.

ControlLogix AutoMax DCSNet and AutoMax Remote I/O Communication Interface Module Slot Location

In thumbwheel test mode, the 56AMXN/B initially displays “Thumb Test Mode”

on the 4-character display, displays the switch settings for 5 seconds, then resumes

displaying “Thumb Test Mode”

For DCS slave operation, if the drop number and drop depth are individually valid

but the combination results in invalid drop numbers (for example, drop number 55,

drop depth 2), the module displays an error message on the 4-character display but

does not enter Thumbwheel test mode.

Prepare the Chassis for Module Installation

Before you install the 56AMXN/B module, you must install and connect a

ControlLogix chassis and power supply.

Determine Module Slot Location

The figure below shows chassis slot numbering in a 4-slot chassis. 

Slot 0 is the first slot and is always the leftmost slot in the rack (the first slot to the right of the power supply). 

You can use any size ControlLogix chassis and install the module in any slot.

You can also install multiple 56AMXN/B modules in the same chassis. 

You can install as many modules as your power supply can accommodate (i.e., number for which the power supply is rated).

ControlLogix AutoMax DCSNet and AutoMax Remote I/O Communication Interface Module

Identify Module Features

Refer to the following figure to identify the hardware components of the 56AMXN/B module.

The module has:

• A label to indicate that it is a scanner for AutoMax

DCSNet and remote I/O

• A 4-character scrolling display (XXXX)

• 3 LEDs, labelled NET, CLX, and OK, to indicate the

status of the network, the connection to the ControlLogix processor, and its own internal state

• a 9-pin D-shell connector to connect to the DCS or remote I/O network

• switches at the top of the module to set the mode of operation and the drop number and drop depth

Set the Network Type and Node Address Switches

Before you install the module, you must set the network type, drop number and drop

depth using the switches at the top of the module.

The two switches at the left set the drop depth, the two at the right set the drop number.

The following table shows how to set the switches for each mode of operation.

For example, to configure the 56AMXN/B as a DCS slave with drop number 17,

drop depth 5, set the switches to 0, 5, 1, and 7 from left to right.

Any other settings are invalid and result in the module going into “Thumbwheel

test” mode. In thumbwheel test mode, the display shows the current switch settings.

It doesn’t go out of thumbwheel test mode until you cycle power.

Rexroth Pressure transducer HM20 R901466598 Throttle

Throttle material 1.4305

Throttle element In the pressure channel of the process interface. It corresponds 

to a nozzle of 0.3 mm and reduces the risk of damage during 

highly dynamic effects such as pressure peaks or cavitation.

Pressure media HL, HLP, HFC, nitrogen 2), others upon request

Tightening torque ▶ Hydraulic connection <400 bar Nm 20 … 25

≥400 bar Nm 25 … 30

▶ Mating connector Nm 0.6 … 1.5 3)

Electrical connection Device connector, 4-pole, M12 x 1 at the housing 4)

Protection class according to EN 60529 IP65/IP67 (if suitable and correctly mounted mating 

connectors are used)

Life cycle 60 million load cycles or 60000 h

Conformity ▶ CE according to the EMC directive

▶ UKCA according to “UK EMC Regulations”

Approvals cULus-listed

DNV marine certification

(For marine applications within the scope of marine approval, 

additional surge protection is required! Based on 

IACS-Unified Requirements E 10)

Rexroth Pressure transducer HM20 R901466598

Features

▶ Measuring pressures in hydraulic systems

▶ 8 measurement ranges up to 630 bar

▶ Sensor with thin film measuring cell

▶ Components that are in contact with the media are made of stainless steel

▶ Operational safety due to high bursting pressure,reversed polarity, overvoltage and short-circuit protection

▶ Characteristic curve deviation <0.5%

▶ Non-repeatability <±0.05%

▶ Ambient temperature range –40 … +85 °C

▶ Marine approval DNV for all variants with current output

Technical data

Weight kg 0.06

Nominal temperature range °C –25 … +80

Ambient temperature range °C –40 … +85

Storage temperature range °C –40 … +80

Medium temperature range °C –40 … +90

Sine test according to DIN EN 60068-2-6 10 … 2000 Hz/maximum of 10 g/10 cycles/3 axes

Noise test according to DIN EN 60068-2-64 20 … 2000 Hz / 14 gRMS / 24 h / 3 axes

Transport shock according to DIN EN 60068-2-27 15 g / 11 ms / 3 axes

Pressure port 1) G1/4 threaded port according to DIN 3852 form E 

Housing materials V4A (1.4404), PEI, HNBR

Material process interface with measuring cell 1.4542 (17-4 PH / 630); seal ring NBR

Rexroth R901342038 HM20-21/315-F-C13-0.50 Pressure sensors Features

This model operates within an extensive temperature range, ensuring consistent performance under varying environmental conditions. 

Additionally, it has received marine approval DNVGL for all variants with current output, 

which attests to its robustness and suitability for maritime applications. 

The component series X to which this transducer belongs indicates 

that it is part of a line designed to handle maximum operating pressures of up to 315 bar.

It offers pressure ratings at several intervals including 100, 160, 250, 315, 400, 600 bar etc., 

providing flexibility for integration into different hydraulic systems. Furthermore, 

the HM 20-2X/315-F-C13-05-N is cULus-listed demonstrating compliance with 

North American safety standards and regulations for industrial control equipment.

Features

Measuring pressures in hydraulic systems 8 measurement ranges up to 630 bar Sensor with 

thin film measuring cell Components that are in contact with the media are made of stainless 

steel Operational safety due to high bursting pressure, reversed polarity, 

overvoltage and short-circuit protection Accuracy class 0.5 Excellent non-repeatability 

< 0.05 % Wide operating temperature range –40 … +85 °C Marine approval DNV-GL for all variants with current output. 

Rexroth R901342038 HM20-21/315-F-C13-0.50 Pressure sensors

Description

The Bosch Rexroth HM 20-2X/315-F-C13-05-N (R901342038) is a high-precision pressure 

transducer designed for monitoring and controlling hydraulic pressures within a wide range of applications. 

This sensor is capable of measuring pressures with ranges up to 600 bar,

making it suitable for various demanding environments where accurate pressure readings are critical. 

The transducer features a thin film measuring cell and components that come into contact with

media are constructed from stainless steel, ensuring durability and compatibility with a variety of fluids. 

With its excellent non-repeatability of less than 0.1% and an accuracy class of 0.5, 

the HM 20-2X/315-F-C13-05-N provides reliable and precise measurements essential for maintaining system performance and safety. 

The device also boasts operational safety features including high bursting pressure capacity, 

reversed polarity protection, overvoltage protection, and short-circuit protection. 

Search for products

Back to Top
Product has been added to your cart