Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Hitachi Energy 520BID01 Binary Input Module

Applications

The module 520BID01 provides 16 galvanically isolated inputs for up to 16 binary process signals.

The input signals are scanned and processed with a time resolution of up to 1 ms. The input signals can be assigned to processing functions according to configuration rules.

The input signals can be assigned to processing functions according to configuration rules.

The module 520BID01 can process the following types of signals or combinations of signals:

– 16 time-stamped single-point messages (SPI)

– 8 time-stamped double-point messages (DPI)

– 2 8-bit digital measured values (DMI8)

– 1 16-bit digital measurement (DMI16)

– 16 integrated totals (max. 25 Hz) (ITI)

– 2 step position information, 8 bits each (STI)

– 2 bit string inputs, 8 bits each (BSI8)

– 1 16-bit bit string input (BSI16)

– or a combination of these signal types

The module is available in two versions (rubrics):

– 520BID01 R0001: Process voltage 24 to 60 VDC.

There are LEDs for each input and a common loop for each of the 8 inputs.

– 520BID01 R0002: Process voltage 110 to 125 V DC.

Each input is signalled by an LED and each of the 8 inputs has a common loop.

Hitachi Energy 520BOD01 Binary Output Module

Applications

The binary output module 520BOD01 controls 8 binary process signals via relay contacts.

The output signals can be assigned to process functions according to configuration rules.

The module 520BOD01 can process the following types of signals:

– Single or dual command (SCO or DCO), 1-pole or 2-pole outputs, no checksum (n select 1).

– Single or dual commands (SCO or DCO) with 1.5- or 2-pole output, no checksum (1 of n) Single or dual commands (SCO or DCO) with 1.5- or 2-pole output, no checksum (1 of n)

– Adjustment Step Command (RCO), 1 or 2 poles

– Digital Setpoint Command, 8-bit, No Strobe (DSO8)

– Digital setpoint command, 8-bit, no strobe (DSO8) Bit-string output, 1 or 8-bit (BSO1 or BSO8)

Modules allow switching voltages up to 150 V DC or up to 8 A continuous current. 8 A continuous current.

Characteristics

Binary Outputs

The binary outputs are relay contacts.

The 8 outputs are isolated from each other. In addition, they are isolated from the internal electronics by means of an optocoupler.

All 8 relay contacts have independent outputs and there are no common circuits.

The command outputs to the process equipment can be executed either directly or in conjunction with the command output monitoring module.

The Command Output Monitoring Module checks the output circuits (1 out of n times). For more details, refer to the Command Output Monitor data sheet.

The following modules with command output monitoring functions are supported:

– 560CIG10

– 560CID11

– 520CSD01

Hitachi Energy 520AID01 Analogue Input Module

Applications

The 520AID01 module records up to 6 analogue measured values.

The module 520AID01 can process the following types of signals

Signals:

– Analogue measured values (AMI)

– Floating-point measurement information (MFI)

The following measurement ranges can be configured

520AID01 R0001:

– ± 2.5 mA

– ± 5 mA

– ± 10 mA

– ± 20 mA

The following measurement ranges can be configured as

520aid01 r0002:

– ± 1 V DC

– ± 10 V DC voltage

Additional valid ranges and real-time zero signals can be generated beyond these ranges by means of conversions in the communication unit (CMU).

The module is available in two versions (rubrics):

– R0001: Current measurement version

– R0002: Voltage measurement version

Hitachi Energy Analogue Output Module 520AOD01

Applications

Analogue control outputs for sequential or closed-loop control, display instruments, measurement recorders, etc,

The analogue output board 520AOD01 can be connected to measuring and recording instruments, etc.

The board 520AOD01 has 2 output channels which can be configured for different voltage or current output ranges.

The module 520AOD01 can process the following types of signals:

– Analogue setpoint commands

– Floating-point setpoint commands

The following output ranges can be configured independently for each channel via on-board switches:

– ± 2.5 mA

– ± 2.5 mA ± 5 mA

– ± 10 mA

– ± 20 mA (4…20 mA) .20 mA)

– ± 1.25 VDC

– ± 2.5 VDC

– ± 5 V DC

– ± 10 V DC

Output formats unipolar, bipolar or real-time zero (4 … 20 mA) are configurable via software parameters. 20 mA) can be configured via software parameters.

Emerson 5X00658G01 Ovation™ Digital Excitation Controller

The controller comes with a variety of functions and features, including:

Powerful processing power: This controller uses a high-speed microprocessor to quickly process a variety of control algorithms and complex process controls.

Multiple Input/Output Interfaces: The controller has a variety of input/output interfaces that allow it to connect to a variety of sensors and actuators for reliable communication with industrial equipment.

Reliability and Stability: The controller is well-designed with high reliability and stability, and can operate stably in various harsh industrial environments.

Scalability: The controller can be integrated with other Emerson controllers or industrial automation equipment for more complex control and monitoring tasks.

Easy to program and maintain: The controller features an easy-to-use programming language and graphical interface for engineers to program and maintain.

The controller also features remote programming and maintenance capabilities for easy remote commissioning and maintenance.

In conclusion, the Emerson 5X00658G01 controller is a powerful, reliable and stable industrial automation device that is widely used in various industrial fields.

Emerson 5X00658G01 controller is a general-purpose controller that can control various industrial equipment and processes.

The specific devices that can be controlled depend on the actual application scenarios and needs, and the following are some common application examples:

Motor Control: The controller can be used to control a variety of motors, such as AC motors, DC motors and stepper motors.

By connecting with a motor driver, functions such as starting, stopping, speed regulation and direction control of the motor can be realised.

Valve control: the controller can be connected with various valves, such as electric valves, pneumatic valves and regulating valves.

By controlling the opening and closing status of the valves, the automatic control of the process can be realised.

Honeywell OEP Control Keypad 51402497-200

Honeywell DCS system has the following characteristics:

High reliability: Honeywell DCS system adopts a decentralized control structure, which disperses system control functions over multiple computers.

Fault-tolerant design ensures that computer failure will not result in the loss of other system functions.

In addition, each computer in the system undertakes a task and uses a dedicated computer with a specific structure and software to realize the functions to be realized.

This increases the reliability of each computer in the system.

Openness: The Honeywell DCS system adopts an open, standardized, modularized and serialized design.

Each computer adopts LAN communication to realize information transmission. When system functions need to be changed or expanded, the

When system functions need to be changed or expanded, newly added computers can be easily connected to or removed from the system communication network, with little or no impact on the work of other computers in the system.

Flexibility: Honeywell DCS systems can be configured with hardware and software based on different process applications.

Determine the measurement and control signals and the connection relationship between them, select the applicable control algorithm from the control algorithm library, the

And call the basic graphics from the graphics library to form a variety of monitoring and alarm images to facilitate the formation of the required control system.

Easy Maintenance: Honeywell DCS systems are characterized by simple and convenient maintenance of small or miniature dedicated computers with a single function.

When a component or computer fails, it can be replaced online without affecting the operation of the entire system in order to quickly clear the fault.

Coordination: Honeywell DCS systems transmit a variety of data between workstations via a communications network and share and coordinate information across the entire system to accomplish the overall function and optimization of the control system.

Complete control functions: Honeywell DCS system has rich control algorithms, integrating continuous control, sequence control and batch control.

It can realize control functions such as serial, feed-forward, decoupling, adaptive and predictive control, etc., and can easily add the required special control algorithms.

Powerful computing capability: Honeywell DCS system adopts high-performance microcomputer processing capability, which can not only realize the control of complex regulating circuits, but also realize the rapid control of switching quantities.

Rich communication interfaces: Honeywell DCS system has a variety of communication interfaces, such as serial communication, Ethernet communication and Profibus communication.

It can exchange data and work together with other industrial automation equipment.

Honeywell 51403165-400 Keyboard Tray Assembly

Honeywell DCS system has the following characteristics:

High reliability: Honeywell DCS system adopts a decentralized control structure, which disperses system control functions over multiple computers.

Fault-tolerant design ensures that computer failure will not result in the loss of other system functions.

In addition, each computer in the system undertakes a task and uses a dedicated computer with a specific structure and software to realize the functions to be realized.

This increases the reliability of each computer in the system.

Openness: The Honeywell DCS system adopts an open, standardized, modularized and serialized design.

Each computer adopts LAN communication to realize information transmission. When system functions need to be changed or expanded, the

When system functions need to be changed or expanded, newly added computers can be easily connected to or removed from the system communication network, with little or no impact on the work of other computers in the system.

Flexibility: Honeywell DCS systems can be configured with hardware and software based on different process applications.

Determine the measurement and control signals and the connection relationship between them, select the applicable control algorithm from the control algorithm library, the

And call the basic graphics from the graphics library to form a variety of monitoring and alarm images to facilitate the formation of the required control system.

Easy Maintenance: Honeywell DCS systems are characterized by simple and convenient maintenance of small or miniature dedicated computers with a single function.

When a component or computer fails, it can be replaced online without affecting the operation of the entire system in order to quickly clear the fault.

Coordination: Honeywell DCS systems transmit a variety of data between workstations via a communications network and share and coordinate information across the entire system to accomplish the overall function and optimization of the control system.

Hitachi Energy 520PTD01 Temperature Measurement Module (PT100)

Applications

The 520PTD01 circuit board is used for direct connection of PT100 temperature transmitters.

Up to six transmitters can be connected to the board. The measuring range is ± 200 °C.

Special features

Basic checks and calculation-intensive cyclic processing functions are already performed on the module, thus reducing the burden on the communication unit.

Relevant changes are transmitted as events via the WRB I/O bus.

The 6 differential inputs are not isolated from the RTU500 series power supply.

The 520PTD01 converts the analogue signal to 4096 steps (12 bits) and measures 100%.

The differential inputs are protected against static and dynamic overvoltage by protection circuitry. A low-pass filter suppresses non-line frequency AC interference.

Two additional channels are used for automatic zero calibration.

The line frequency is configurable in the configuration tool.

The microcontroller uses these configuration parameters to set up the A/D converter.

Hitachi Energy 520ADD01 Input/Output Adapter

520ADD01 Input/Output Adapter

DIN rail mounting base module RTU540

Expansion of wired or bus (WRB) with additional RTU520 I/O modules

Number of modules selectable via front jumper (4 or 8)

Inputs: WRB, ribbon cable

Outputs: WRB, ribbon cable

Applications

I/O adapter 520ADD01 for connecting RTU520 I/O modules to RTU520 or RTU540 communication modules

Features

The I/O adapter connects to the WRB I/O bus (wired OR bus) and automatically generates the address of the connected I/O module within the I/O assembly.

Two green LEDs on the module indicate activity on the I/O bus.

Hitachi Energy 520ADD02 Input/Output Adapter

Applications

I/O adapter 520ADD02 for connecting more than 16 RTU520 I/O modules to the

RTU520 or RTU540 to an I/O bus with RS485 or fibre optic connection.

The adapter can also be used to extend the WRB I/O bus in decentralised I/O applications.

The maximum distance is up to 2 kilometres and the distance between the I/O adapters needs to be more than 30 cm.

In addition, I/O adapter 520ADD02 can be used as a stand-alone module to extend the RTU560 I/O modules (e.g. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40. 23BE40).

(e.g. 23BE40. 23BE50. 23BA40) to the RTU540.

The module is available in two versions (standard)

– R0001: RS485

– R0002: RS485 and glass fibre optics, 840 nm

Features

The I/O adapter connects to the WRB I/O bus (wired OR bus)

The I/O adapter connects to the WRB I/O bus (wired OR bus) and automatically generates the address of the connected I/O module within the I/O assembly.

The I/O adapter is always the last adapter unit in Virtual I/O Chassis 1.

The adapter converts the WRB I/O bus to the SPB I/O bus (Serial Peripheral Bus) via RS485 or fibre optic connection.

The glass fibre optic module is compatible with the 23OK24 and 560FOC40 modules.

There are two green LEDs on the module to indicate activity on the I/O bus.

Search for products

Back to Top
Product has been added to your cart