Line Scan Trigger Capability

Coaxlink supports both continuous roll scanning (to inspect infinite, continuously moving surfaces

without losing lines)

and discrete target scanning (to capture images of targets moving in front of the camera).

(to capture images of targets moving in front of the camera).

– Triggers are used to initiate acquisition when the part is in position. 

Hardware triggers are from the motherboard I/O lines. Software triggers come from the application.

– Once initiated, the acquisition will continue indefinitely (for rolling the network):

– Continue indefinitely (for rolled-net monitoring applications)

– continue for a programmable number of lines (to acquire a target image of known length)

– continue until an end trigger signal is received (to acquire variable length target images)

– Controllable delay trigger to delay the start of acquisition by a programmable number of lines.