Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Emerson DeltaV™ M-series Decreases installation time and expense

Decreases installation time and expense

Plug-and-play installation saves money: All Traditional I/O components plug into the I/O interface carrier.

You can install the I/O interface carriers to manage anticipated growth and postpone

the I/O interfaces until you’re ready to install your additional field devices.

Phased installation saves time: As soon as you mount the I/O interface carrier, you’re ready to begin installing the field devices.

I/O terminal blocks plug directly onto the I/O interface carrier.

There is no need to have the I/O cards installed.

Keys: Traditional I/O interfaces and terminal blocks have  I/O function keys.

These keys ensure that the correct I/O  card is always plugged into the corresponding terminal block.

It’s incredibly easy to use and gives you time to do more.

This design enables you to initially install Traditional I/O  quickly and efficiently.

When you need to replace an I/O card, the function key design ensures that you will always install  it correctly.

This keying system provides a safety measure  by preventing the wrong I/O interface’s being installed.

Emerson OCR3000 Ovation™ Control Execution 

Control Execution 

Like the Ovation OCR1100 controller, the OCR3000 performs complex modulation,

discrete and sequential control strategies, as well as data acquisition and monitoring functions.

The OCR3000 controller can generate up to 64,000 points. 

With a quad-core processor, the OCR3000 controller supports up to five control tasks with loop speeds ranging from 10 milliseconds to 300 seconds.

Each control task consists of an I/O flow point input scan, a control scheme execution, and an output scan.

The loop speed for all five control tasks is user selectable.

Each of the five control tasks can range from 10 milliseconds to 300 seconds.

Connectivity 

The OCR3000 includes an embedded Ethernet link protocol driver for connecting to intelligent electronic devices

(IEDs) and other third-party devices with embedded controllers, such as smart inverters and other devices.

The OCR3000 includes embedded Ethernet link protocol drivers to communicate with intelligent electronic devices (IEDs)

and other third-party devices with embedded controllers, such as smart inverters,

weather stations, relay protection systems, or motor control centers.

The Scalable Controller performs data acquisition functions by using on-board communication protocol drivers to communicate

with Ethernet-enabled I/O systems from a wide range of vendors, as well as various types of PLCs, PACs, and RTACs.

Emerson Ovation™ Controller Model OCR3000 Process Applications

Process Applications

The OCR3000 controller is designed to meet the demanding requirements

of a wide range of process applications, including :

Continuous PID (Proportional-Integral-Derivative) control 

Sequential function chart control 

Boolean logic 

Advanced Control 

Model predictive control 

Fuzzy logic 

Neural Networks  

Special Logic and Timing Functions 

Data Acquisition 

Event Sequence Processing 

Process point sensor/limit checking 

Process point alarm handling 

Process point conversion to engineering units 

Process point database storage 

Local and remote I/O interfaces 

Process point labeling

Emerson PACSystems™ RX3i CPE302 Controller Features

Features

Programming tools such as tag-based programming, a library of reusable code and a test edit mode for

improved online troubleshooting

User-friendly environment that can increase design flexibility and improve engineering efficiency and

productivity Plug-and-play addition of PROFINET-enabled devices makes it easy to securely connect

machines, data and people

High-speed multicore processor for faster throughput without information bottlenecks

Support for high-density discrete I/O, universal analog (TC, RTD, Strain Gauge,

Voltage and Current configurable per channel), isolated analog, high-density analog, high-speed counter,

and motion modules

Isolated serial port for robust and reliable integration of sensors and instruments

PACSystems™ RX3i controllers provide the foundation for Industrial Internet connectivity.

It is a powerful, modular Programmable Automation Controller with a focus on high availability.

The RX3i features a single control engine and a universal programming environment to provide

application portability across multiple hardware platforms.

Emerson PACSystems™ RX3i CPE302 Controller Specifications

Product Description

PACSystems™ RX3i controllers provide the foundation for Industrial Internet connectivity.

It is a powerful, modular Programmable Automation Controller with a focus on high availability.

The RX3i features a single control engine and a universal programming environment to provide

application portability across multiple hardware platforms.

Specifications

Part NumberIC695CPE302

Form FactorBackplane

User Memory2MB

I/O16k Bits Discrete I/O, 32k Words for Analog I/O

Energy PackIncluded

Redundancy SupportMedia Redundancy (MRP) with PNC001

Ethernet Port1 – 2 port switch 10/100/1000

Ethernet ProtocolsSRTP Client/Server, Modbus TCP/IP, OPC UA , EGD, PROFINET, DNP3 Outstation,

IEC-61850 Client, IEC-104 Server, HART passthrough

Serial ProtocolsASCII Serial, Modbus/RTU

Remote I/O Devices255 Simplex with PNC001

USB Interface1x USB-A 2.0

Environmental0 to 60C

Agency ApprovalsUKCA, UL, cUL, RoHS, CCC, FCC, Reach, UL HazLoc C1D2. ATEX Zone 2

Marine CertificationsABS, BV, LR. DNV GL

Emerson PACSystems™ RX3i 64 MB CPU w/Ethernet IC695CPE330 Switches

▪ Supports programming in Ladder Diagram, Structured Text, Function Block Diagram, or C.

▪ Contains 64 Mbytes of configurable data and program memory.

▪ Supports auto-located Symbolic Variables that can use any amount of user memory.

▪ Contains reference tables include 32k bits for discrete %I and %Q and up to

32k words each for analog %AI and %AQ. Bulk memory (%W) also supported

for data exchanges.

▪ Supports up to 768 program blocks. Maximum size for a block is 128KB.

▪ Configured to display serial number and date code in PME Device Information Details.

▪ Configured for Coordinated Universal Time (UTC) and Day Light Savings Time (DST) support.

▪ Operating temperature range 0 C to 60 C (32 F to 140 F).

▪ Compliant with EU RoHS Directive 2002/95/EC using the following

exemptions identified in the Annex: 7(a), 7(c)-I and III, and 15.

Switches

The Run/Stop switch and RDSD UPLD and RDSD DNLD pushbuttons are

located behind the protective front door. Switch operation is given in the

following table.

The Run/Stop switch is enabled by default; it can be disabled in the PME

Hardware Configuration (HWC) settings. The memory protection function

of this switch can be disabled separately in HWC. The memory protection

functionality is disabled by default.

Emerson PACSystems™ RX3i 64 MB CPU w/Ethernet IC695CPE330 PROFINET systems

▪ Supports RX3i Hot Standby Redundancy with Ethernet (EGD) & Genius I/O.

▪ Enabled simplex PROFINET I/O controller with support for up to 32 I/O

devices and update rates of 1 – 512 ms. I/O device update rates of 8 ms

and faster are possible with 16 or fewer devices. When there are more than

16 devices configured, update rates of 16 ms and higher are available.

▪ Supports the Remote Get HART® Device Information COMMREQ, which

allows the user application to read information from a HART device

connected to an RX3i Analog module in an IC695PNS001 RX3i PROFINET

Scanner. A UDFB that automates the COMMREQ control logic is available for

download. (Refer to New Features and Enhancements for additional information.)

▪ Configured with Sequence of Events recording through the Embedded

PROFINET Controller when used with up to four IC695PNS101 Advanced

PROFINET Scanner modules. A RX3i SoE system supports events from up to

512 SoE input points with a system storage buffer for up to 128.000 events at

a maximum rate of 400 events per second per PNS101. Each PNS101

supports SoE recording with IRIG B time synchronization of events accurate

to 1ms and buffers up to 4000 events from up to four IC694MDL660

32 Circuit Discrete Input modules. Unmodulated IRIG B time signals are

decoded by the PNS101 using either an IC695HSC304 or IC695HSC308 High

Speed Counter Module. SoE recording is available in both simplex and

redundant PROFINET systems.

Emerson PACSystems™ RX3i 64 MB CPU w/Ethernet IC695CPE330 Features

User Features

The PACSystems™ RX3i CPE330 is a richly featured programmable

controller CPU equipped with 64 Mbytes of built-in program memory and

two independent high-speed Ethernet interfaces. It is ideally suited for

multi-tier communications and for synchronizing large amounts of data.

Its metal housing provides superior noise immunity.

The CPE330 is programmed and configured over Ethernet via PAC

Machine Edition™ (PME) software. It resides in the RX3i main rack and

supports all RX3i I/O and Intelligent Option modules, up to 32K I/O

points.

▪ Supports an updated OPC stack and certificate management

▪ Supports PME’s new GUI management interface for OPC UA configuration

integration (start, stop, restart, clear, and provisioning mode)

▪ Supports the new PAC Security tool available for certificate trust

management for clients and servers

▪ Supports RX3i Hot Standby Redundancy CPU with PROFINET® I/O using

embedded PROFINET or using rack-mounted IC695PNC001 PROFINET

Controllers.

Emerson PACSystems™ RX3i Central Processing Unit IC695CPE302 User Features

▪ Supports Battery-less retention of user memory

▪ Configured with an Energy Pack IC695ACC400 to power the CPU long enough

to write user memory to non-volatile storage (NVS) on system power loss

▪ Equipped with configurable data and program memory

▪ Supports programming in Ladder Diagram, Structured Text, Function Block

Diagram, and C

▪ Supports auto-located Symbolic Variables that can use any amount of user memory

▪ Equipped with reference table sizes to include 32 Kbits for discrete %I and %Q

and up to 32Kwords each for analog %AI and %AQ

▪ Supports most Series 90-30 modules and expansion racks. For supported I/O,

Communications, Motion, and Intelligent modules, refer to the PACSystems

RX3i Hardware and Installation Manual, GFK-2314

▪ Supports up to 512 program blocks (Maximum size for a block is 128KB)

▪ Configured with an RS-232 serial port

▪ Enabled with an embedded Ethernet interface to support up to 32

simultaneous SRTP Server connections, up to 16 simultaneous Modbus/TCP

Server connections, and up to 16 simultaneous communications channels of

either SRTP Channels or Modbus/TCP Client channels. For details, refer to the

PACSystems RX3i TCP/IP Ethernet Communications User Manual, GFK-2224

▪ Supports OPC UA

▪ Supports Ethernet Global Data, Class 1

▪ Supports HART® Pass Through

▪ Time synchronization to SNTP Time Server on Ethernet network when used

with a rack-based Ethernet module (IC695ETM001) version 5.0 or later

▪ Enhanced ability to display serial number and date code in PME’s Device

I nformation Details.

▪ Ability to transfer applications to and from USB 2.0 A type removable data

storage devices, or RDSDs.

▪ Compliant with EU RoHS Directive 2002/95/EC using the following

exemptions identified in the Annex: 7(a), 7(c)-I and III, and 15.

Emerson PACSystems™ RX3i Central Processing Unit IC695CPE302 Features

User Features

The PACSystems™ RX3i CPE302 can be used to perform real time control of

machines, processes, and material handling systems. The CPU

communicates with the programmer via the internal Ethernet port or a

serial port. It communicates with I/O and Intelligent Option modules over a

dual PCI/Serial backplane.

▪ Supports an updated OPC stack and encrypting connections

▪ Supports PME’s new GUI management interface for OPC UA configuration

integration (start, stop, restart, clear, and provisioning mode)

▪ Supports the new PAC Security tool available for certificate trust management

of clients and servers

▪ Contains 5 Mbytes of user memory and 5 Mbytes of non-volatile flash user

memory

▪ Supports Battery-less retention of user memory

▪ Configured with an Energy Pack IC695ACC400 to power the CPU long enough

to write user memory to non-volatile storage (NVS) on system power loss

▪ Equipped with configurable data and program memory

▪ Supports programming in Ladder Diagram, Structured Text, Function Block

Diagram, and C

Search for products

Back to Top
Product has been added to your cart