Configuring Your SLC Processor, Off-line
This procedure assumes you are using RSLogix500E Programming Software,
version 2.10 or later. For other software, the procedure may vary.
1. Open your 1746-QV project, VELMOD.
2. Configure the type of SLC processor. To do this:
A. Open the file, Controller Properties.
B. Select the SLC processor type and click OK.
3. Configure the rack size, module slot, and module ID:
A. Open the file, I/O Configuration.
B. Select the rack size.
C. Highlight the slot number for the module.
D. From the list of modules, scroll to 1746-QV and double–click.
If the module is not listed:
– Scroll to Other and double-click.
– Enter the module’s ID (13115) and double-click.
4. Size the “G” file:
A. Highlight 1746-QV (or 13115 if module was not listed).
B. Click [Adv Config].
C. In the dialog box, enter a G-file length of 7.
D. Press [Edit G Data].
We used values from the ladder logic example (appendix B).