Special Function

• Auto Economizer

• Process PI Controller

• Traverse Function

• Selectable Fault Reset & Run

• Auto Restart on Power Up

• Speed Sensitive Electronic Overload

• Auto-tuning

• Step Logic

Operational

• Selectable Volts/Hertz Mode

• Multi-lingual selection

Programmable

• Dual Accel/Decel Profiles

• Three Skip Frequencies

• DC Injection Braking

• Dynamic Braking

• Slip Compensation

• Negative Slip Compensation(Droop)

• S Curve Accel/Decel Profile

• Line Loss Restart Mode

• Proactive Current Limit

• Last Four Event Fault Memory

• Flying Start

• Seven Preset Speeds

I/O Interface

• Control Output Contacts

(2) Form A (N.O.)

(2) Form C (N.O. – N.C.)

Programmable to 17

different drive variables.

• Flexible Analog

Inputs/Outputs

• Pulse Train Input

• Encoder Feedback Closed

Loop Speed Control

• High Speed Input

Diagnostics

Real time preventive maintenance coupled with

customized status and fault reporting.

Depending upon your particular drive configuration, status and

fault conditions can be reported through the Human Interface

Module or through the SCANport™ Communications Port. Fault

diagnostic routines are started each time the 1336 PLUS II is

powered up. Throughout the entire run sequence, the drive will

continue to look for potential fault conditions.

To allow real-time preventive maintenance, drive output current

and control conditions can be selectively monitored while the drive

is running. The operator is made aware of alarm conditions such as

current limit, bus voltage status, motor overload or drive overload

before the drive reaches a fault level. Should a fault occur, plain

language diagnostic messages will help identify and isolate the

problem, allowing personnel to take quick, corrective actio