Merlin Embedded MVME4905/06 Digital-Synchro/Resolver Converter Module Environmental

Environmental

• Operating Temperature: -20 to 85 °C

• Storage Temperature: -40 to 125 °

• Shock: 25g, 11ms on all axis

• Humidity: 95% Rel. Humidity, non-condensing

The MVME4905 is designed to be a drop-in

replacement for the VMIVME-4905 from GE-IP. The

MVME4906 is designed to be a drop-in replacement

for two VMIVME-4905’s on the same board.  The unit

offers the following improvements over the GE-IP

VMIVME-4905

• The MVME4906 can be configured as two VMIVME

4905’s with a different base address jumper and I/O

connector for each set of two channels.

• Onboard built in test emulates the VMIVME-4905

with a VMIVME-4911.  S/D section has its own base

address jumper.

• Optical Isolation

• Price is 30% less than VMIVME-4905.

• No external 15V supply is required.

• Conduction cooled version available.

Merlin Embedded MVME4905/06 Digital-Synchro/Resolver Converter Module Specifications

Specifications

• Channels:  2 for MVME4905. 4 for MVME4906

• Resolution:  16-bit

• Accuracy: ±4 arc minutes

• Output Type:  3 wire for Synchro or 4-wire for

resolvers

• Internal transformers (400 Hz options)

• 5 VA, 2 VA (transformer output)

• Onboard S/D or R/D converter for built in test.

VME Specifications

• Conforms with VME Specifications Revision C.1 IEEE

Std. 1014-1987

• Board size: 6U

As with all Merlin Embedded drop-in replacement

products, the MVME4905 will function with the

customer’s existing software and cabling that used for

the original product.  No changes are required.

Significant cost savings can be obtained by customer’s

who use multiple VMIVME-4905’s with the SR05

backplane and VMIVME-4911 for diagnostics.  The

MVME4906 is a dual VMIVME-4905 with a built in

VMIVME-4911 channel for diagnostics.

Communications Modules IC697CMM742 Functions

Functions

The IC697CMM742 Ethernet Interface (Type 2)

provides high performance TCP/IP communications for the IC697 PLC.

The Ethernet Interface (Type 2) plugs into a single slot

in an IC697 PLC rack and is configured with the IC641

PLC programming software.  Up to four Ethernet

Interface (Type 2) modules can be installed in an IC697 PLC CPU rack.

The Ethernet Interface (Type 2) contains three network

ports: 10BaseT (RJ-45 connector), 10Base2 (BNC

connector), and AUI (15-pin D-connector).

The Ethernet Interface automatically selects the network

port in use.  One network port may be used at a time.

The 10BaseT network port permits direct connection to

a 10BaseT (twisted pair) network hub or repeater

without an external transceiver.

The 10Base2 network port permits direct connection to

a 10Base2 (ThinWire ) network without an external transceiver.

The AUI network port permits attachment of a user

supplied AUI (Attachment Unit Interface, or transceiver) cable.

The AUI cable connects the Ethernet Interface to a user-supplied transceiver

that is directly connected to the 10Mbps Ethernet network.

The transceiver must be 802.3 compatible and must have the SQE option enabled.

Communications Modules IC697CMM742 Features

Features

Connects IC697 PLC to an IEEE 802.3 CSMA/CD

10Mbps Ethernet LAN via one of three network

ports: 10BaseT, 10Base2. or AUI

10BaseT and 10Base2 network ports provide direct

connection to 10BaseT or 10Base2 network with

out an external transceiver

Standard 15-pin AUI network port allows  choice

of 10Base5. 10Base2. 10BaseT, 10BaseF, or

10Broad36 medium with user-supplied 802.3-com

patible transceiver

Firmware is pre-loaded for easy installation and is

maintained indefinitely; firmware is easily upgradedin-system from PC attached to RS-485 serial port

The Ethernet Interface provides:

Data exchange using configuration-based and

logic-based Ethernet Global Data

TCP/IP communication services using SRTP

Full PLC programming and configuration services

Comprehensive station management and diagnostic tools

PACSystem RX3i Universal Backplane IC695CHS012 Installation

RX3i Universal Backplane Installation

The RX3i system and its components are considered open equipment (having live electrical parts that may

be accessible to users) and must be installed in a protective enclosure or incorporated into other

assemblies manufactured to provide safety.  As a minimum, the enclosure or assemblies must provide

protection equivalent to a NEMA/UL Type 1 enclosure or an IP20 rating (IEC60529). The enclosure must

be able to adequately dissipate theheat generated by all of the components mounted inside so that no

components overheat.  A minimum space of at least 102mm (4 inches) as shown below is required on all

sides of the RX3i backplane for cooling.  Additional space may be required, depending on the amount of

heat generated by the equipment during operation.

Please refer to the PACSystems RX3i System Manual, GFK-2314. for information about enclosures and

heat dissipation.

Backplane Orientation

Backplanes must be mounted horizontally to meet product

performance and reliability specifications by providing

adequate airflow around the modules.  Other mounting

orientations may affect system performance and/or reliability

and are therefore not recommended.

PACSystem RX3i Universal Backplane IC695CHS012 Backplane Orientation

The PACSystems* RX3i Universal Backplanes provide a dual-bus backplane that supports PCI-based

(IC695) and serial (IC693 and IC694) I/O and option modules. The RX3i Universal Backplanes also

support Series 90-30 IO and option modules.  See the PACSystems RX3i System Manual, GFK-2314 for

lists of supported modules. The 16-slot Universal Backplane (IC695CHS016), and the 12-slot Universal

Backplane (IC695CHS012) include the following features:

▪ Terminal Strip on the left end for Isolated +24V input

▪ Backplane grounding point

▪ An integral grounding bar for connecting module/shield grounds

▪ Serial Expansion connector for connection to Serial Expansion and Remote Backplanes

▪ Slot numbers printed on the backplane that can be used as a reference for configuration.

The 12-slot Universal Backplane (IC695CHS012) is illustrated below.

Backplane Orientation

Backplanes must be mounted horizontally to meet product

performance and reliability specifications by providing

adequate airflow around the modules.  Other mounting

orientations may affect system performance and/or reliability

and are therefore not recommended.

Kelman Transport X² Portable Onsite DGA Application Example

Application Example

The Kelman Transport X² remains your ideal partner for use in conjunction

with GE’s range of single gas online DGA monitors. These units (such as

Hydran™ 201Ti and Hydran M2-X) monitor the transformer and raise an

alarm when an abnormal level of fault gas is reached or when the rate of

change of this gas level increases rapidly so that you can take action and

protect your transformer early in the process.

Such events often require further investigation before a valid conclusion

can be reached. Traditional methods require an oil sample to be sent to a

laboratory for analysis. This can be a lengthy process before a diagnosis

and related decision can be made. However, with the Transport X², the

sample can be taken and analyzed onsite, giving comprehensive diagnostic

information in less than 30 minutes. The Transport X² data can then be

uploaded and visualized in GE’s powerful Perception software alongside  the

readings from the online monitor.

Kelman Transport X² Portable Onsite DGA Applications

Applications

As the average age of generation, transmission and distribution transformers increases, the risk of rapid

deterioration and even catastrophic failures also increases. Transformer changes can occur in between

rounds of periodic laboratory DGA analysis and this risk exposure can go unnoticed. The Transport X²

offers electric utility and industrial customers accurate, economical and portable DGA and diagnostics in

an easy to-use handy instrument that is applicable for:

• Mission critical industrial transformers

• Distribution transformers

• Buchholz relay gas

• Tap changer tanks

• Instrument transformers

• Oil filled circuit breakers

Key Benefits

• Measurement of seven diagnostic gases and moisture content in the oil

• Fast diagnostics in less than 30 minutes

• Intuitive touchscreen interface with step-by-step instructions and Plug and Play connectivity

• Compatible with mineral insulating oils and newer ester-based fluids (natural and synthetic)

• Enables operators to effectively respond to alarms, trip events and supports on-site field decision

making

• Ideal companion to GE’s range of single gas online DGA monitors for adding transformer diagnostics

Kelman Transport X² Portable Onsite DGA ​Key Benefits

Key Benefits

• Measurement of seven diagnostic gases and moisture content in the oil

• Fast diagnostics in less than 30 minutes

• Intuitive touchscreen interface with step-by-step instructions and Plug and Play connectivity

• Compatible with mineral insulating oils and newer ester-based fluids (natural and synthetic)

• Enables operators to effectively respond to alarms, trip events and supports on-site field decision making

• Ideal companion to GE’s range of single gas online DGA monitors for adding transformer diagnostics

Applications

As the average age of generation, transmission and distribution transformers increases, the risk of rapid

deterioration and even catastrophic failures also increases. Transformer changes can occur in between

rounds of periodic laboratory DGA analysis and this risk exposure can go unnoticed. The Transport X² offers

electric utility and industrial customers accurate, economical and portable DGA and diagnostics in an easy

to-use handy instrument that is applicable for:

• Mission critical industrial transformers

• Distribution transformers

• Buchholz relay gas

• Tap changer tanks

• Instrument transformers

• Oil filled circuit breakers

Kelman Transport X² Portable Onsite DGA

Dissolved Gas Analysis (DGA) and moisture measurement of insulating fluids are recognized as the most

important tests for condition assessment of fluid-insulated transformers. Every year asset owners deploy

field crews to take thousands of fluid samples from transformers as part of periodic health checks and for

immediate operational decisions. These samples are sent to offsite laboratories for analysis.

Kelman™ Transport X² is a portable ‘lab in a box’ delivering detailed analysis with dramatically reduced

turnaround times. In critical situations, the ability to perform DGA in less than 30 minutes on the spot,

empowers asset owners to determine a transformer’s condition onsite and thereby allow operational

decisions to be made at the earliest opportunity.

GE was the first to deliver consumable-free DGA products to the market and the Transport X² represents

the next generation of its portable system. GE’s class leading Photo-acoustic spectroscopy (PAS) gas

measurement technology, now in its fourth generation, provides laboratory-challenging levels of

precision in a calibration free, easy-to-use and hand-carriable product.

Benefiting from over 40 years of global DGA experience, the Transport X² encapsulates intuitive

advancements to bring improved performance, innovative new features, enhanced user experience and

greater robustness.

Search for products

Back to Top
Product has been added to your cart